Search results for "result"
showing 10 items of 2426 documents
Do Intensity Ratings and Skin Conductance Responses Reliably Discriminate Between Different Stimulus Intensities in Experimentally Induced Pain?
2010
Abstract The present study addresses the question whether pain-intensity ratings and skin conductance responses (SCRs) are able to detect different intensities of phasic painful stimuli and to determine the reliability of this discrimination. For this purpose, 42 healthy participants of both genders were assigned to either electrical, mechanical, or laser heat-pain stimulation (each n = 14). A whole range of single brief painful stimuli were delivered on the right volar forearm of the dominant hand in a randomized order. Pain-intensity ratings and SCRs were analyzed. Using generalizability theory, individual and gender differences were the main contributors to the variability of both intens…
Technical note: a comparison of central and peripheral intraocular pressure using rebound tonometry
2007
Purpose: To compare central and peripheral intraocular pressure (IOP) readings obtained with rebound tonometry.Methods: Intraocular pressure was measured on the right eye of 153 patients (65 males, 88 females), aged from 21 to 85 years (mean +/- S.D., 55.5 +/- 15.2 years) with the ICare rebound tonometer at centre, and 2 mm from the limbus (in the nasal and temporal regions along the 0-180O corneal meridian).Results: Intraocular pressure values obtained with the ICare were 14.9 +/- 2.8; 14.1 +/- 2.5 and 14.5 +/- 2.7 mmHg at centre, nasal and temporal corneal locations, respectively. On average, nasal and temporal IOP readings were 0.75 and 0.37 mmHg lower than the central reading (p 0.05, r…
Role of high-resolution ultrasonography without and with real-time spatial compound imaging in evaluating the injured posterior cruciate ligament: pr…
2009
This study sought to compare high-resolution ultrasonography (HRUS) without and with compound imaging in evaluating the injured posterior cruciate ligament (PCL). Thirteen patients with a magnetic resonance imaging (MRI) diagnosis of PCL lesions (ten acute and three chronic) and 20 healthy controls underwent conventional and compound HRUS performed by the same radiologist who was blinded to the subjects' case-control status. The PCL was scanned in a longitudinal direction in all cases. HRUS images were assessed for PCL thickness by two other radiologists blinded to the number and type of PCL injury. PCLs were classified as normal or injured, and the latter as having acute or chronic injurie…
Performance of a new device for the clinical determination of light discomfort
2020
PURPOSE To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was assessed by means of within-subject standard deviation, coefficient of variation (CoV), and intraclass correlation coefficient (ICC). Repeated measures ANOVA, Kruskal-Wallis, and correlation analysis were applied to test for differences between repeated measures, and effect of age on reliability. RESULTS Discomfort thresholds obtained are well distributed across the light intensity…
Comparison of Electrocochleography and Video Head Impulse Test findings in Vestibular Migraine and Ménière Disease: A Preliminary Study
2020
OBJECTIVES: To evaluate electrophysiological findings among patients with vestibular migraine (VM) and to compare them with those of patients suffering from definite Ménière disease (MD) without migraine. MATERIALS and METHODS: Twenty-one consecutive patients suffering from VM were enrolled; all subjects were selected according to the criteria proposed by the Bàràny Society for Neuro-otology. Each patient underwent a careful otological and neurotological examination. After completing a questionnaire regarding migraine and vertigo complaints, they were assessed by audiometric testing, video head impulse test (vHIT), and elec-trocochleography (EcochG). Data were compared with those of 21 pati…
Validity and reliability of the Migraine-Treatment Optimization Questionnaire.
2009
Our aim was to establish the validity and reliability of a patient-rated Migraine Treatment Optimization Questionnaire (M-TOQ in primary care. Patients who met International Classification of Headache Disorders, 2nd edn criteria for migraine completed a 19-item questionnaire containing candidate items for the M-TOQ and three questionnaires designed to test convergent/construct validity [Migraine Disability Assessment Scale (MIDAS), Headache Impact Test (HIT)-6 and Migraine-Specific Quality of Life Scale (MSSQoL)]. A 15-item (M-TOQ15) and a five-item (M-TOQ-5) questionnaire were derived. Two hundred and fifty-three adult patients were recruited. Five treatment optimization domains were iden…
Assessing decentering: validation, psychometric properties, and clinical usefulness of the Experiences Questionnaire in a Spanish sample.
2014
Decentering is defined as the ability to observe one’s thoughts and feelings in a detached manner. The Experiences Questionnaire (EQ) is a self-report instrument that originally assessed decentering and rumination. The purpose of this study was to evaluate the psychometric properties of the Spanish version of EQ-Decentering and to explore its clinical usefulness. The 11-item EQ-Decentering subscale was translated into Spanish and psychometric properties were examined in a sample of 921 adult individuals, 231 with psychiatric disorders and 690 without. The subsample of nonpsychiatric participants was also split according to their previous meditative experience (meditative participants, n = 3…
Multiple sclerosis severity score: Using disability and disease duration to rate disease severity
2005
Background: There is no consensus method for determining progression of disability in patients with multiple sclerosis (MS) when each patient has had only a single assessment in the course of the disease. Methods: Using data from two large longitudinal databases, the authors tested whether cross-sectional disability assessments are representative of disease severity as a whole. An algorithm, the Multiple Sclerosis Severity Score (MSSS), which relates scores on the Expanded Disability Status Scale (EDSS) to the distribution of disability in patients with comparable disease durations, was devised and then applied to a collection of 9,892 patients from 11 countries to create the Global MSSS. I…
Italian version of the Chicago multiscale depression inventory: translation, adaptation and testing in people with multiple sclerosis.
2004
Depression is the commonest psychiatric disturbance in people with multiple sclerosis (MS), with prevalence higher than in the general population and other chronic diseases. However, accurate assessment of depressive symptoms can be biased by somatic symptoms which are part of both MS and depression. We translated and adapted into Italian the Chicago multiscale depression inventory (CMDI) and assessed its acceptability, internal consistency and test-retest reliability in 213 MS outpatients and 213 individually matched healthy controls. The questionnaire was also tested in 32 people with major depression. Acceptability, internal consistency, and test-retest reliability were good overall. We …
Reliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer.
2007
The aim of this study was to evaluate the reliability of isokinetic and isometric assessments of the knee extensor and the flexor muscle function using the Con-Trex isokinetic dynamometer. Thirty healthy subjects (15 males, 15 females) were tested and retested 7 days later for maximal strength (isokinetic peak torque, work, power and angle of peak torque as well as isometric maximal voluntary contraction torque and rate of torque development) and fatigue (per cent loss and linear slope of torque and work across a series of 20 contractions). For both the knee extensor and the flexor muscle groups, all strength data - except angle of peak torque - demonstrated moderate-to-high reliability, wi…