Search results for "result"
showing 10 items of 2426 documents
Nitrate-induced coronary vasodilation by stress-magnetic resonance imaging: A novel noninvasive test of coronary vasomotion
2004
Purpose To evaluate the feasibility of assessing coronary vasodilation following exogenous nitrates, using magnetic resonance angiography (MRA). The assessment of coronary response to exogenous nitrovasodilators may have a diagnostic and prognostic impact in patients with coronary artery disease. To date, stress imaging of coronary artery vasomotion has been confined to the catheterization laboratory. MRA is emerging as a noninvasive tool for coronary artery imaging. Materials and Methods Coronary MRA was performed in 20 healthy volunteers (12 males, age = 33 ± 8). We used spiral spoiled gradient echo (SSGE) sequences for imaging of coronary artery lumen. After the baseline short-axis view …
Comparison of two different labial salivary gland biopsy incision techniques: A randomized clinical trial
2013
Objectives: To compare the reliability of two different labial salivary gland biopsy (LSGB) incision techniques (vertical versus horizontal incision techniques) and to report the related complications and discomfort. Study Design: 163 patients who underwent LSGB were included in this study. Patients were randomly divided as vertical incision group (n=81) and horizontal incision group (n=82). Demographic and clinical information of each patient were recorded. A questionnaire was prepared and applied together with Visual Analog Scale (VAS) on the subjects verbally at the 7th day, postoperatively. Intraoperative, short- term and delayed complications were evaluated. Results: The mean age of pa…
Computerized acoustic voice analysis and subjective scaled evaluation of the voice can avoid the need for laryngoscopy after thyroid surgery.
2008
Because of frequent postoperative alterations in voice, many surgeons include laryngoscopy as a routine examination before/after thyroid surgery. The aim of this work was to determine whether more comfortable and easier subjective or objective postoperative voice assessments could complement or replace laryngoscopy.Sixty-four consecutive patients scheduled to undergo thyroid surgery underwent preoperative objective computerized acoustic voice analysis (CAVA), subjective scaled evaluation of the voice (SSEV) with the GIRBAS scale, and fiberoptic laryngoscopy. All patients had 7- and 30-day postoperative follow-up assessments using the same tests.CAVA measurements of jitter and noise-to-harmo…
Body Composition and Fitness during Strength and/or Endurance Training in Older Men
2008
PURPOSE: This study examined adaptations in body composition and physical fitness during a 21-wk strength and/or endurance training period in 40- to 65-yr-old men. We also compared the usefulness of different methods for the analysis of body composition to detect training-induced adaptations. METHODS: Fifty-three men were randomized into the endurance training (E: N = 14), strength training (S: N = 13), combined strength and endurance training (SE: N = 15), or control (C: N = 11) groups. S and E trained 2 and SE 2 x 2 times a week for strength and endurance. RESULTS: Percentage of fat (fat%) decreased (5-8%) similarly in all training groups. Fat% measured by DXA at baseline and its change c…
Vocational training integrated into inpatient psychosomatic rehabilitation--short and long-term results from a controlled study.
2005
Purpose. The aim of this study was to determine the impact of a vocational training programme on short- and long-term results after psychosomatic rehabilitation. Method. 1,590 inpatients were screened for vocational integration. A high-risk group of 266 patients was randomly assigned to the vocational training programme plus psychosomatic treatment; treatment- as- usual served as a control condition. An occupational training was conducted at local companies, closely integrated into psychosomatic treatment. Vocational attitudes and adjustment were studied at intake, discharge, three, 12 and 24 month follow-ups. Results. More than half of the study participants were unemployment and/or long-t…
Design and validation of a patient-reported outcome measure scale in acute pancreatitis: the PAN-PROMISE study
2021
ObjectiveThis study aimed to develop and validate a patient-reported outcome measure (PROM) in acute pancreatitis (AP) as an endpoint centred on the patient.DesignA PROM instrument (PAtieNt-rePoRted OutcoMe scale in acute pancreatItis, an international proSpEctive cohort study, PAN-PROMISE scale) was designed based on the opinion of patients, professionals and an expert panel. The scale was validated in an international multicentre prospective cohort study, describing the severity of AP and quality of life at 15 days after discharge as the main variables for validation. The COSMIN (COnsensus-based Standards for the selection of health status Measurement INstruments) methodology was applied.…
Clinical evaluation of a wireless ECG sensor system for arrhythmia diagnostic purposes
2013
Accepted version of an article in the journal: Medical Engineering and Physics. Also available from the publisher at: http://dx.doi.org/10.1016/j.medengphy.2013.03.002 In a clinical study, a novel wireless electrocardiogram (ECG) recorder has been evaluated with regard to its ability to perform arrhythmia diagnostics. As the ECG recorder will detect a "non-standard" ECG signal, it has been necessary to compare those signals to "standard" ECG recording signals in order to evaluate the arrhythmia detection ability of the new system. Simultaneous recording of ECG signals from both the new wireless ECG recorder and a conventional Holter recorder was compared by two independent cardiology specia…
Two-dimensional echocardiographic evaluation of left ventricular ejection fraction by the ellipsoid single-plane algorithm: a reliable method for ass…
1995
The reliability of two-dimensional (2D) echocardiographic estimation of left ventricular ejection fraction (EF) is commonly recognized, but no satisfactory data are available about the accuracy of low or very low EF values determined by 2D echocardiography (ECHO-EF). The purpose of our study was to assess the reliability of low ECHO-EF values obtained using a simple time-economical algorithm such as the ellipsoid single-plane area-length method. Radionuclide angiography (RAD-EF) was taken as the standard of comparison. We studied 59 consecutive patients (31 women and 28 men) referred to our echocardiographic laboratory. Both 2D echocardiography and radionuclide angiography were blindly perf…
Development and validation of the Migraine Screen Questionnaire (MS-Q).
2005
Aim.—To develop and evaluate the clinimetric properties of a new migraine screening questionnaire: the Migraine Screen Questionnaire (MS-Q). Background.—Migraine is a public health problem requiring screening programs and tools to ensure early detection. Methods.—A questionnaire was developed based on the criteria of the International Headache Society (IHS) and a review of the literature by a committee of experts. Stage I: The original version of the MS-Q was distributed by mail and completed by Pfizer employees and self-administered to neurological patients; all subjects were afterward evaluated by a neurologist who was blinded to the MS-Q results, to establish an independent IHS diagnosis…
Standardized T2* map of normal human heart in vivo to correct T2* segmental artefacts.
2007
A segmental, multislice, multi-echo T2* MRI approach could be useful in heart iron-overloaded patients to account for heterogeneous iron distribution, demonstrated by histological studies. However, segmental T2* assessment in heart can be affected by the presence of geometrical and susceptibility artefacts, which can act on different segments in different ways. The aim of this study was to assess T2* value distribution in the left ventricle and to develop a correction procedure to compensate for artefactual variations in segmental analysis. MRI was performed in four groups of 22 subjects each: healthy subjects (I), controls (II) (thalassemia intermedia patients without iron overload), thala…