Search results for "result"

showing 10 items of 2426 documents

Parenting Stress Profile and Children Behaviour in Patients with Congenital Hypothyroidism

2015

Background: Hypothyroidism has been associated with cognitive and motor impairments, the degree to which mild hypothyroidism, or subclinical hypothyroidism impacts mood and cognitive functions and whether these symptoms respond to treatment, remains controversial. Furthermore, hypothyroidism is associated with an increased susceptibility to depression and reductions in health-related quality of life. Objective and hypotheses: Recent longitudinal studies stressed that the follow-up of children with treated congenital hypothyroidism (CHT) should not be limited to the cognitive domain. This study attempted to evaluate the emotional–behavioural profiles in children with CHT and the parenting st…

Denver test resultsSettore MED/38 - Pediatria Generale E SpecialisticaCongenital Hypothyroidismparenting stre
researchProduct

Assessing therapist development: Reliability and validity of the Supervisee Levels Questionnaire (SLQ-R).

2019

BACKGROUND Therapist development is a crucial target for clinical training in order to ensure high-quality psychotherapy. A major challenge in examining therapeutic development is the assessment of developmental processes. The Supervisee Levels Questionnaire (SLQ-R) was analyzed in this study to examine its validity, reliability, and underlying dimensional structure. METHOD Seven hundred and sixty therapists participated in an online survey concerning their current psychotherapy training. The factor structure as well as the validity of the SLQ-R were investigated using exploratory and confirmatory factor analysis. RESULTS In line with the results of the exploratory factor analyses, a Bifact…

Department PsychologieAdultMalePsychometricsPsychotherapy TrainingClinical supervisionReproducibility of ResultsFactor structureStructural equation modelingConfirmatory factor analysisPsychotherapyClinical PsychologyEmpirical researchArts and Humanities (miscellaneous)Clinical trainingSurveys and QuestionnairesHumansFemaleddc:610Clinical CompetencePsychologyReliability (statistics)Clinical psychologyJournal of clinical psychology
researchProduct

On-line analysis of carbonyl compounds with derivatization in aqueous extracts of atmospheric particulate PM10 by in-tube solid-phase microextraction…

2011

Abstract A new device for carbonyl compounds based on coupling on-line and miniaturizing both, sample pretreatment and chromatographic separation, is reported. Two capillary columns, a GC capillary column (95% methyl–5% phenyl substituted backbone, 70 cm × 0.32 mm i.d., 3 μm film thickness) in the injection valve for in-tube solid-phase microextraction (IT-SPME) and a Zorbax SB C18 (150 mm × 0.5 mm i.d., 5 μm particle diameter) LC capillary column were employed. Different combinations of IT-SPME and derivatization using 2,4-dinitrophenylhydrazine (DNPH) were examined for mixtures containing 15 carbonyl compounds (aliphatic, aromatic and unsaturated aldehydes and ketones). A screening analys…

Detection limitAldehydesAqueous solutionChromatographyCapillary actionOrganic ChemistryReproducibility of ResultsGeneral MedicineParticulatesReference StandardsSolid-phase microextractionBiochemistrySensitivity and SpecificityAnalytical ChemistryAcetonechemistry.chemical_compoundchemistryCapillary columnTube (fluid conveyance)Particulate MatterParticle SizeDerivatizationSolid Phase MicroextractionChromatography LiquidJournal of chromatography. A
researchProduct

Green determination of eight water-soluble B vitamins in cosmetic products by liquid chromatography with ultraviolet detection.

2021

Abstract B vitamins are a group of compounds with beneficious properties for dermatologic care, and therefore they are included in the cosmetic formulations as high added-value ingredients. In this paper, an analytical method for the simultaneous determination of eight water-soluble B vitamins in cosmetic products is reported for the first time. This method is based on liquid chromatography with ultraviolet detection (LC-UV) analysis after simple water leaching of the analytes from the cosmetic matrix. No organic solvents are required, beyond the ethanol used in the chromatographic mobile phase. The proposed method has been successfully validated showing good linearity, limits of detection …

Detection limitAnalyteChromatographyChemistryClinical BiochemistryPharmaceutical ScienceReproducibility of ResultsWaterRepeatabilityCosmeticsmedicine.disease_causeAnalytical ChemistryMatrix (chemical analysis)B vitaminsWater solubleLeaching (chemistry)Drug DiscoveryVitamin B ComplexmedicineSolventsSpectroscopyUltravioletChromatography High Pressure LiquidChromatography LiquidJournal of pharmaceutical and biomedical analysis
researchProduct

Sequential-injection determination of traces of disodium phenyl dibenzimidazole tetrasulphonate in urine from users of sunscreens by on-line solid-ph…

2005

Abstract A sensitive and selective method to determine disodium phenyl dibenzimidazole tetrasulphonate (PDT) in the urine of sunscreen users, which is suitable for studies on body accumulation/excretion is proposed. On-line solid-phase extraction allows the analyte to be retained and subsequentely eluted, using a strong anion exchange (SAX) microcolumn. Standard addition calibration was carried out with only one standard. The wavelengths of excitation and emission were 330 and 454 nm, respectively. The method allows PDT to be determined in both, spiked and unspiked human urine samples, without any pre-treatment. Results obtained for spiked urine samples (40–200 ng ml −1 ) showed the accurac…

Detection limitAnalyteChromatographyChemistryElutionAdministration TopicalSkin AbsorptionClinical BiochemistryFluorescence spectrometryReproducibility of ResultsPharmaceutical ScienceUrineHydrogen-Ion ConcentrationAnalytical ChemistryExcretionSpectrometry FluorescenceStandard additionFlow Injection AnalysisDrug DiscoveryHumansBenzimidazolesSolid phase extractionSunscreening AgentsSpectroscopyJournal of Pharmaceutical and Biomedical Analysis
researchProduct

New micromethod combining miniaturized matrix solid-phase dispersion and in-tube in-valve solid-phase microextraction for estimating polycyclic aroma…

2008

Abstract Miniaturized matrix solid-phase dispersion (MSPD) was developed for the extraction of common polycyclic aromatic hydrocarbons (PAHs) from bivalve samples (100 mg, dry weight). Additional clean-up and analyte enrichment was accomplished by in-tube solid-phase microextraction (SPME). For this purpose the extracts collected after MSPD were diluted with water and injected into a capillary column coated with the extractive phase. This capillary column was connected to the analytical column by means of a switching valve. Separation and quantification of the PAHs were carried out using a monolithic LC column and fluorescence detection. Since the in-tube SPME device allowed the processing …

Detection limitAnalyteChromatographyChemistryOrganic ChemistryExtraction (chemistry)Analytical chemistryReproducibility of ResultsGeneral MedicineReference StandardsSolid-phase microextractionBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryBivalviaMatrix (chemical analysis)AnimalsSample preparationSolid phase extractionPolycyclic Aromatic HydrocarbonsSolid Phase MicroextractionChromatography LiquidJournal of chromatography. A
researchProduct

Protein mapping by two-dimensional high performance liquid chromatography.

2000

Current developments in drug discovery in the pharmaceutical industry require highly efficient analytical systems for protein mapping providing high resolution, robustness, sensitivity, reproducibility and a high throughput of samples. The potential of two-dimensional (2D) HPLC as a complementary method to 2D-gel electrophoresis is investigated, especially in view of speed and repeatability. The method will be applied for proteins of a molecular mass <20 000 which are not well resolved in 2D-gel electrophoresis. The 2D-HPLC system described in this work consisted of anion- or cation-exchange chromatography in the first dimension and reversed-phase chromatography in the second dimension. We …

Detection limitAnalyteChromatographyElutionChemistryOrganic ChemistryIon chromatographyAnalytical chemistryProteinsReproducibility of ResultsGeneral MedicineRepeatabilityReversed-phase chromatographyChromatography Ion ExchangeBiochemistryHigh-performance liquid chromatographyPeptide MappingSensitivity and SpecificityAnalytical ChemistryTwo-dimensional chromatographyChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

A direct Capillary Liquid Chromatography with electrochemical detection method for determination of phenols in water samples

2010

A fast and direct method based on the use of Capillary Liquid Chromatography (LC) with electrochemical (EC) detection has been described for phenols pollutants in water samples. Concretely, phenol, o-cresol, 2-chlorophenol and bisphenol A have been selected as target analytes. The combination of Capillary LC with EC detection avoided the necessity of preconcentration steps typically used in environmental analysis. The sample injected volume was 2 μL. The achieved detection limits were between 1 and 2 μg/L and the linear dynamic range was up to 50 μg/L for all studied phenols. The precision and uncertainty were satisfactory. The analysis time per sample was 10 min. The proposed procedure has…

Detection limitAnalyteChromatographyEnvironmental analysisCapillary actionOrganic ChemistryAnalytical chemistryReproducibility of ResultsFresh WaterGeneral MedicineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundPhenolschemistryCapillary ElectrochromatographyLinear ModelsPhenolSeawaterPhenolsQuantitative analysis (chemistry)Water Pollutants ChemicalJournal of Chromatography A
researchProduct

Advantages of monolithic over particulate columns for multiresidue analysis of organic pollutants by in-tube solid-phase microextraction coupled to c…

2011

Abstract The performance of a monolithic C 18 column (150 mm × 0.2 mm i.d.) for multiresidue organic pollutants analysis by in-tube solid-phase microextraction (IT-SPME)-capillary liquid chromatography has been studied, and the results have been compared with those obtained using a particulate C 18 column (150 mm × 0.5 mm i.d., 5 μm). Chromatographic separation has been carried out under isocratic elution conditions, and for detection and identification of the analytes a UV-diode array detector has been employed. Several compounds of different chemical structure and hydrophobicity have been used as model compounds: simazine, atrazine and terbutylazine (triazines), chlorfenvinphos and chlorp…

Detection limitAnalyteChromatographyMonolithic HPLC columnTriazinesCapillary actionPhenylurea CompoundsOrganic ChemistryDinitroanilineAnalytical chemistryReproducibility of ResultsContext (language use)General MedicineSolid-phase microextractionSensitivity and SpecificityBiochemistryAnalytical Chemistrychemistry.chemical_compoundOrganophosphorus CompoundschemistryChromatography columnSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

Improving analysis of apolar organic compounds by the use of a capillary titania-based column: Application to the direct determination of faecal ster…

2010

This article reports a new procedure for the direct determination of faecal sterols coprostanol and cholesterol in wastewater samples as tracers of human sewage contamination. The method combines in-tube solid-phase microextraction (IT-SPME) for analyte enrichment and capillary liquid chromatography (LC) for separation with diode array detection for identification and quantification. A titania-based polymeric capillary column and a conventional octadecyl silica (ODS) capillary column were evaluated and compared for their ability to separate the analytes. The titania-based column allowed the separation of the analytes in much shorter chromatographic times and with better chromatographic prof…

Detection limitAnalyteChromatographySewageChemistryOrganic ChemistryReproducibility of ResultsGeneral MedicineReversed-phase chromatographySolid-phase microextractionBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryCoprostanolCholestanolchemistry.chemical_compoundFecesCholesterolWastewaterHumansSample preparationSolid Phase MicroextractionChromatography LiquidJournal of chromatography. A
researchProduct