Search results for "result"
showing 10 items of 2426 documents
Automated trace enrichment for screening and/or determination of primary, secondary and tertiary amphetamines in biological samples by liquid chromat…
1999
A rapid and simple liquid chromatographic method for the automated determination of amphetamines in biological fluids was developed. The proposed procedure is based on the injection of 250 microL of sample into a 20 x 2.1 mm id precolumn (packed with a 30 microns Hypersil C18 stationary phase) for enrichment and purification of the analytes. Next, the analytes are transferred to a 5 microns LiChrospher 100 RP18, 125 x 4 mm id analytical column for their separation under reversed-phase conditions. Water was used to eliminate the matrix components from the precolumn and a 0.2 M phosphate buffer (pH 3) containing 2% triethylamine was the mobile phase for the resolution of the amphetamines. The…
Electrochemical detection of chloride ions using Ag-based electrodes obtained from compact disc
2022
Abstract In this work electrochemical sensors fabricated from compact disc material (waste or new) are used to quantify chloride ions in different types of samples. All three electrodes, working, counter, and pseudo-reference electrodes, were fabricated from the compact disc and directly used. Different parameters were studied in order to demonstrate the possibility of using this waste material for efficient and low-cost electrochemical sensors. Chloride sensing performance was evaluated using linear scan voltammetry as the detection technique. A sensitivity of 0.174 mA mM−1 cm−2 with a limit of detection of 20 μM and excellent selectivity against many interferents was observed. Selectivity…
Multi-class determination of antimicrobials in meat by pressurized liquid extraction and liquid chromatography–tandem mass spectrometry
2008
A multi-residue method using pressurized liquid extraction (PLE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for determining trace levels of 31 antimicrobials, including beta-lactams, lincosamides, macrolides, quinolones, sulfonamides, tetracyclines, nitroimidazoles and trimethoprim. The extraction method required pre-homogeneization of the meat with EDTA-washed sand and subsequent one-static-cycle extraction for 10 min with 40 ml of water at 1500 psi and 70 degrees C. The effect of operation temperature, pressure, flush volume, and static cycles on PLE performance was studied. Average recoveries ranged from 75 to 99% with relative standard deviations <1…
Development of stir bar sorptive-dispersive microextraction mediated by magnetic nanoparticles and its analytical application to the determination of…
2014
A novel microextraction technique combining the principles of stir bar sorptive extraction (SBSE) and dispersive micro-solid phase extraction (DμSPE) is presented. The main feature of the method is the use of a neodymium-core stirring bar physically coated with a hydrophobic magnetic nanosorbent. Depending on stirring speed, the magnetic sorbent either acts as a coating material to the stir bar, thus affording extraction alike SBSE, or as a dispersed nanosorbent medium for the collection and extraction of the target analytes, in close analogy to DμSPE. Once the stirring process is finished, the strong magnetic field of the stir bar prevails again and rapidly retrieves the dispersed MNPs. Al…
Evaluation of solid-phase extraction and stir-bar sorptive extraction for the determination of fungicide residues at low-microg kg(-1) levels in grap…
2004
Abstract A liquid chromatography–mass spectrometry method has been developed for determining bitertanol, carboxin, flutriafol, pyrimethanil, tebuconazole and triadimefon. The evaluation of both atmospheric pressure interfaces (API), atmospheric pressure chemical ionization (APCI) and electrospray (ESI) using positive and negative ionization modes, clearly shows that the studied pesticides are more sensitive using APCI in positive mode. Two procedures based on solid-phase extraction (SPE) and stir-bar sorptive extraction (SBSE) have been assessed for extracting these compounds in grape. The recoveries obtained by SPE in samples spiked at the limit of quantification (LOQ) level ranged from 60…
Analysis of currently used pesticides in fine airborne particulate matter (PM 2.5) by pressurized liquid extraction and liquid chromatography-tandem …
2008
During and after the application of currently used pesticides (CUPs) a significant fraction of applied pesticides can be lost to the air. A confirmatory and rapid procedure has been developed for the determination of four fungicides (carbendazim, thiabendazol, imazalil and bitertanol), three insecticides (imidacloprid, methidathion and pyriproxyfen), one helicide (methiocarb) and one acaricide (hexythiazox) in fine airborne particulate matter (PM 2.5) at trace level. The proposed method includes extraction of PM 2.5-bound pesticides by pressurized liquid extraction (PLE) followed by a direct injection into LC-MS/MS. The main parameters affecting the performance of the electrospray ionizatio…
Quantification of low levels of amorphous content in sucrose by hyperDSC.
2005
A method was developed for the quantification of low levels of amorphous content in sucrose with hyperDSC. The method was based on the fact that the change of specific heat at the glass transition is linearly proportional to the amorphous content. It was found out that as annealing time increased, the glass transition temperature moved to a higher temperature and the change of specific heat increased. DeltaC(p) for annealed totally amorphous sucrose was 0.761+/-0.012 Jg(-1) degrees C(-1). Synthetic mixtures with various proportions of crystalline and amorphous sucrose were prepared. The following linear regression between DeltaC(p) and amorphous content was obtained: DeltaC(p)=0.0075x - 0.0…
Late results of bladder stimulation in 11 patients: followup to 4 years.
1978
Abstract Direct stimulation of the detrusor muscle offers the best possibility to evacuate the bladder in highly selected patients. During the last 4 years 11 patients have undergone implantation of a bladder pacemaker. Followup revealed that 1 patient could void only during stimulation, while 7 patients had reflex evacuation and 3 had no function at all. An exceptional case report is presented.
Search for Subsolar Mass Ultracompact Binaries in Advanced LIGO's Second Observing Run
2019
We present a search for subsolar mass ultracompact objects in data obtained during Advanced LIGO’s second observing run. In contrast to a previous search of Advanced LIGO data from the first observing run, this search includes the effects of component spin on the gravitational waveform. We identify no viable gravitational-wave candidates consistent with subsolar mass ultracompact binaries with at least one component between \ud0.2\ud \ud \udM\ud⊙\ud–\ud1.0\ud \ud \udM\ud⊙\ud. We use the null result to constrain the binary merger rate of (\ud0.2\ud \ud \udM\ud⊙\ud, \ud0.2\ud \ud \udM\ud⊙\ud) binaries to be less than \ud3.7\ud×\ud10\ud5\ud \ud \udGpc\ud−\ud3\ud \udyr\ud−\ud1\udand the binary …
HADES experiment: di-lepton spectroscopy in p + p (2.2 GeV) and C+C (1 and 2 A GeV) collisions
2006
The HADES (High Acceptance Di-Electron Spectrometer) is a tool designed for lepton pair (e+e−) spectroscopy in pion, proton and heavy ion induced reactions in the 1–2AGeV energy range. One of the goals of the HADES experiment is to study in-medium modifications of hadron properties like effective masses, decay widths, electromagnetic form factors etc. Such effects can be probed with vector mesons ( ρ,ω,ɸ ) decaying into e+e− channel. The identification of vector mesons by means of a HADES spectrometer is based on invariant mass reconstruction of e+e− pairs. The combined information from all spectrometer sub-detectors is used to reconstruct the di-lepton signal. The recent results from 2.2Ge…