Search results for "rise time"
showing 6 items of 16 documents
Silicon-loaded surface plasmon polariton waveguides for nanosecond thermo-optical switching
2014
A MHz-bandwidth thermo-optical (TO) plasmonic switch operating at telecommunication wavelengths and based on a hybrid solid-state silicon-loaded surface plasmon polariton waveguide design is demonstrated numerically. The nanosecond (ns) TO response of the switch is due to the high thermal conductivities of the employed materials and we demonstrate specifically a 10 dB extinction ratio in the time-dependent switch transmission which features a pulsed 1 ns rise time followed by a 25 ns fall time when the switch is photo-thermally activated by a ns pulse at 532 nm wavelength.
Probing the Merits of Different Event Parameters for the Identification of Light Charged Particles in CHIMERA CsI(Tl Detectors With Digital Pulse Sha…
2013
We investigated the merits of different event parameters in the identification of Light Charged Particles (LCPs) with CsI(Tl) scintillators read out by photodiodes at high incident energy (400 MeV/u). This investigation is made possible by digital signal processing the output signals. As in the conventional analogue case, the digitized signals allow the discrimination of light charged particles by computing the fast and slow components. In addition other identification parameters as the rise time of the output pulses of the CsI(Tl) come out nearly for free. Aim of this paper is the investigation of novel identification plots and the probe of their merits, in particular at relativistic energ…
Performance of HPGe detectors in high magnetic field
2006
A new generation of high-resolution hypernuclear gamma$-spectroscopy experiments with high-purity germanium detectors (HPGe) are presently designed at the FINUDA spectrometer at DAPhiNE, the Frascati phi-factory, and at PANDA, the antiproton proton hadron spectrometer at the future FAIR facility. Both, the FINUDA and PANDA spectrometers are built around the target region covering a large solid angle. To maximise the detection efficiency the HPGe detectors have to be located near the target, and therefore they have to be operated in strong magnetic fields B ~ 1 T. The performance of HPGe detectors in such an environment has not been well investigated so far. In the present work VEGA and EURO…
Light Charged Particle Identification by Means of Digital Pulse Shape Acquisition in the CHIMERACsI(Tl) Detectors at GSI Energies
2011
We report the results obtained by applying digital pulse shape acquisition and digital signal processing to the signals from CsI(Tl) scintillators read out by photodiodes at high incident energy (400 MeV/u). The digitized signals allows the discrimination of light charged particles by computing the Fast and Slow components and the Rise Time of the output pulses of the CsI(Tl). When the energies of the light charged particles exceed those corresponding to their ranges in CsI(Tl), the points related to the punching-through particles gather in the corresponding scatter plots giving rise to a cusp. The punching-through points are used as energy calibration points for the reaction products stopp…
Intrapulmonary 3He Gas Distribution Depending on Bolus Size and Temporal Bolus Placement
2008
OBJECTIVE: Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on inspiratory gas distribution. MATERIALS AND METHODS: An ultrafast 2-dimensional spoiled gradient echo sequence (temporal resolution 100 milliseconds) was used for dynamic ventilation (3)He-MRI of 11 anesthetized and mechanically ventilated pigs. The applied (3)He gas bolus was varied in volume between 100 and 200 mL. A 150-mL bolus was varied in its application time after the beg…