Search results for "sample preparation"

showing 10 items of 343 documents

Retrospective screening of pesticide metabolites in ambient air using liquid chromatography coupled to high-resolution mass spectrometry

2015

A new methodology for the retrospective screening of pesticide metabolites in ambient air was developed, using liquid chromatography coupled to Orbitrap high-resolution mass spectrometry (UHPLC-HRMS), including two systematic workflows (i) post-run target screening (suspect screening) and (ii) non-target screening. An accurate-mass database was built and used for the post-run screening analysis. The database contained 240 pesticide metabolites found in different matrixes such as air, soil, water, plants, animals and humans. For non-target analysis, a "fragmentation-degradation" relationship strategy was selected. The proposed methodology was applied to 31 air samples (PM10) collected in the…

ChromatographyPesticide residueCarbendazimAir010401 analytical chemistryPesticide ResiduesAnalytic Sample Preparation MethodsAnalytic Sample Preparation Methods010501 environmental sciencesPesticideMass spectrometryOrbitrap01 natural sciencesMass Spectrometry0104 chemical sciencesAnalytical Chemistrylaw.inventionchemistry.chemical_compoundMalaoxonchemistrylawEnvironmental chemistryOmethoateChromatography High Pressure Liquid0105 earth and related environmental sciencesTalanta
researchProduct

Sample preparation methods for the determination of pesticides in foods using CE-UV/MS.

2010

Much progress has been made in pesticide analysis over the past decade, during this time hyphenated techniques involving highly efficient separation with sensitive detection have become the techniques of choice. Among these, methods based on separation with mass spectrometric detection have resulted in greater likelihood of identification and are acknowledged to be extremely useful and authoritative methods for the determination of pesticide residues but the inherent advantages of the use of CE as a separation technique are well-known and can be summarized as high separation efficiency, low analysis time, high resolution power, and low consumption of samples and reagents. Although UV is the…

ChromatographyPesticide residueChemistryClinical BiochemistryHigh resolutionElectrophoresis CapillaryLimitingPesticideChemical FractionationMicrofluidic Analytical TechniquesBiochemistryMass spectrometricFood AnalysisMass SpectrometryAnalytical ChemistryCapillary electrophoresisSample preparationSpectrophotometry UltravioletBiochemical engineeringPesticidesFood AnalysisElectrophoresis
researchProduct

The Role of the Liquid Chromatography-Mass Spectrometry in Pesticide Residue Determination in Food

2008

The use of liquid chromatography (LC) in pesticide residue determination was usually limited to groups of compounds or single compounds for which no suitable gas chromatographic (GC) conditions were available. However, recent developments have significantly enlarged the LC scope in this field of analysis. One of the most important advances was the on-line coupling of efficient LC separation with mass spectrometry detectors (LC-MS and LC-MS/MS) that makes this technique an excellent method for the determination of pesticides and their transformation products in complex matrices such as food. This review considers the application of LC-MS/MS in this field. Emphasis is placed on the tandem MS …

ChromatographyPesticide residueLiquid chromatography–mass spectrometryChemistryAnalytical chemistryThermosprayDirect electron ionization liquid chromatography–mass spectrometry interfacePesticideTandem mass spectrometryMass spectrometrySample preparation in mass spectrometryAnalytical ChemistryCritical Reviews in Analytical Chemistry
researchProduct

Last trends in pesticide residue determination by liquid chromatography–mass spectrometry

2014

Liquid chromatography–mass spectrometry (LC–MS) is as an excellent analytical tool in the determination of pesticides. Multiresidue analysis of these compounds at trace levels is one of the oldest analytical schemes within environmental and food safety. However, the issue of “pesticide residue determination” is still a hot topic for the analytical community. This review discusses current approaches and recent advances in using LC–MS for pesticide identification and quantification. We outline how MS has influenced the sample preparation process. We critically assess and compare various mass spectrometers, highlighting their strengths and limitations. We, then, review the main applications of…

ChromatographyPesticide residueLiquid chromatography–mass spectrometryChemistryEnvironmental chemistryPesticide identificationEnvironmental ChemistrySample preparationPesticideMass spectrometryAnalytical ChemistryTrends in Environmental Analytical Chemistry
researchProduct

Infrared biospectroscopy for a fast qualitative evaluation of sample preparation in metabolomics.

2014

Liquid chromatography-mass spectrometry (LC-MS) has been increasingly used in biomedicine to study the dynamic metabolomic responses of biological systems under different physiological or pathological conditions. To obtain an integrated snapshot of the system, metabolomic methods in biomedicine typically analyze biofluids (e.g. plasma) that require clean-up before being injected into LC-MS systems. However, high resolution LC-MS is costly in terms of resources required for sample and data analysis and care must be taken to prevent chemical (e.g. ion suppression) or statistical artifacts. Because of that, the effect of sample preparation on the metabolomic profile during metabolomic method d…

ChromatographyPlasma samplesChemistryPlasma compositionIon suppression in liquid chromatography–mass spectrometryBlood ProteinsMass spectrometryMethod developmentMass SpectrometryAnalytical ChemistryMice Inbred C57BLExploratory data analysisMetabolomicsSpectroscopy Fourier Transform InfraredAnimalsMetabolomicsSample preparationFemaleChromatography LiquidTalanta
researchProduct

Effect of solvents on the selectivity of terbutylazine imprinted polymer sorbents used in solid-phase extraction

2002

A solid-phase extraction sample preparation method using a molecularly imprinted polymer (MIP) selective for the triazine type pesticide terbutylazine has been developed. The method involves preconcentration from large volumes of water samples on a C18 disk coupled to selective clean-up on the MIP. The method has been optimised by studying the recovery and retention of terbutylazine and some other structurally related triazine derivates as a function of the selective washing solvent used. The effect of the water content of the selective washing solvent was also investigated on the recovery of the MIP. River water samples were analysed with the coupled technique, and efficient clean-up of th…

ChromatographyPolymersTriazinesOrganic ChemistryExtraction (chemistry)Molecularly imprinted polymerGeneral MedicineBiochemistryAnalytical ChemistrySolventchemistry.chemical_compoundchemistrySolventsSample preparationSolid phase extractionSolvent effectsMolecular imprintingTriazineJournal of Chromatography A
researchProduct

Determination of water-soluble vitamins in energy and sport drinks by micellar electrokinetic capillary chromatography

2016

Abstract A method for the determination of water-soluble vitamins in several energy and sport drinks by micellar electrokinetic chromatography (MEKC) has been developed in this work. The separation of vitamins was studied in terms of background electrolyte composition (borate content, pH, surfactant type and content) and in other MEKC parameters. A study of the possible compounds found in the vitamin-enriched drinks that could interfere in vitamin determination was also performed, and a modified procedure with enhanced resolution was developed. The proposed method was successfully applied to the analysis of water-soluble vitamins in a variety of energy and sport drinks and also in fruit nec…

ChromatographyResolution (mass spectrometry)Chemistry010401 analytical chemistry04 agricultural and veterinary sciences040401 food science01 natural sciencesMicellar electrokinetic chromatography0104 chemical sciences0404 agricultural biotechnologyPulmonary surfactantReagentWater-Soluble VitaminSample preparationElectrolyte compositionSoft drinkFood ScienceBiotechnologyFood Control
researchProduct

Solubility of some pesticides in supercritical CO2

1988

The solubility limits of some pesticides (Linuron, Methoxychlor, Diclofopmethyl, Diclofop and 2,4-D) and of 3,4-dichloroaniline have been determined in supercritical CO2 at 200 bar and 40° C, using the Milton Roy sample preparation accessory SPATM. Depending on the polarity and vapour pressure of the investigated compounds, the solubility was found to be between 0.3 and 12 gl−1.

ChromatographyVapor pressureClinical BiochemistrySupercritical fluid extractionMethoxychlorGeneral MedicinePesticideSupercritical fluidAnalytical Chemistrychemistry.chemical_compoundchemistryGeneral Materials ScienceSample preparationSolubilityBar (unit)Fresenius' Zeitschrift für analytische Chemie
researchProduct

Supercritical Fluid Extraction and Supercritical Fluid Chromatography of Vitamin E in Pharmaceutical Preparations

1999

ChromatographyVitamine eChemistryGeneral Chemical EngineeringVitamin Emedicine.medical_treatmentSupercritical fluid extractionDosage formlaw.inventionlawSupercritical fluid chromatographymedicineFlame ionization detectorSample preparationQuantitative analysis (chemistry)Journal of High Resolution Chromatography
researchProduct

Peptides analysis in blood plasma using on-line system of supported liquid membrane and high-performance liquid chromatography

2005

The potential of using supported liquid membrane (SLM) technique, combined with reversed-phase high-performance liquid chromatography (RP-HPLC) has been investigated for the determination of peptides in human blood plasma. The peptides studied were (DL)Leu(DL)Phe, MetLeuPhe, GlyLeuTyr and ValGluProlleProTyr. The carrier (Aliquat 336) was incorporated in membrane phase in order to facilitate the transport of investigated peptides. After extraction, the analyte-enriched acceptor phase was directly injected into an HPLC system for analysis. With SLM, high selectivity and efficiency were achieved for extraction of peptides in aqueous solutions. Lower extraction efficiency was obtained in plasma…

Chromatographyaliquat 336Extraction (chemistry)Analytical chemistryUltrafiltrationReversed-phase chromatographyAliquat 336BiochemistryHigh-performance liquid chromatographyAnalytical ChemistryStandard curvechemistry.chemical_compoundMembranechemistrypeptidesEnvironmental ChemistrySample preparationsupported liquid membraneHPLCSpectroscopyblood plasmaAnalytica Chimica Acta
researchProduct