Search results for "sample preparation"
showing 10 items of 343 documents
Determination of cyromazine in pesticide commercial formulations by vibrational spectrometric procedures
2004
Two vibrational spectrometry-based methodologies were developed for Cyromazine determination in solid pesticide formulations: a Fourier transform infrared (FTIR) procedure, based on the extraction of Cyromazine by CH3OH and direct determination in the extracts by peak height measurement at 1622 cm−1 corrected using a baseline defined at 1900 cm−1, and a FT-Raman determination, made directly on the powdered solid products using standard chromatographic glass vials as sample cells and measuring the Raman intensity between 633 and 623 cm−1 for a baseline established between 663 and 601 cm−1. The sensitivity obtained was 0.01631 absorbance g−1 mg for FTIR determination and 2.23 area values g−1 …
Fourier transform infrared determination of imidacloprid in pesticide formulations
2004
A simple method has been developed for Fourier Transform Infrared (FTIR) determination of Imidacloprid in pesticide formulations. Samples were diluted with CHCl3 and the FTIR spectra of samples and standards were obtained at a nominal resolution of 4 cm-1 from 4000 to 900 cm-1 accumulating 25 scans. Imidacloprid determination was based on the measure of either peak area from 1577 to 1567 cm-1 or peak height at 1572 cm-1, both corrected using a horizontal baseline defined at 1900 cm-1. The limits of detection achieved, of the order of 9 µg g-1, were appropriate for the determination of Imidacloprid in commercially available formulations. FTIR results were statistically comparable to those fo…
Optimization of LC–MS/MS using triple quadrupole mass analyzer for the simultaneous analysis of carbosulfan and its main metabolites in oranges
2006
This paper describes an analytical method involving a simple solvent extraction for the simultaneous liquid chromatography coupled to quadrupole tandem mass spectrometry (LC-MS/MS) determination of carbosulfan, its most toxic metabolite--carbofuran--, and its other main metabolites--3-hydroxycarbofuran, 3-ketocarbofuran, 3-hydroxy-7-phenolcarbofuran, 3-keto-7-phenolcarbofuran, 7-phenolcarbofuran and dibutylamine--in oranges. Chromatography was performed on a Zorbax Bonus-RP (150 mm x 2.1 mm, 5 microm). The mobile phase was a ternary gradient water-methanol-acetonitrile with 1.0 mM ammonium acetate at flow rate of 0.2 ml min(-1). The LC separation and MS/MS optimization were studied to selec…
Quantification of Imidacloprid in Honeybees: Development of a Chemiluminescent ELISA
2010
A Chemiluminescente Enzyme-Linked Immuno-Sorbent Assay (CL-ELISA) for determination and quantification of the fungicide imidacloprid in honeybees was developed in an indirect competitive format. The assay was optimized by determining: the optimal coating conjugate concentration and anti-imidacloprid antiserum dilution, the effect of the incubation time on the competitive step, the tolerance to organic solvents. The IC50 and the limit of detection (LOD) values were 14.8 ng mL-1 and 0.11 ng mL -1, respectively, similar to those of colorimetric ELISA with a calibration range of 0.1 – 2600 ng mL-1. Cross reactivity of some related compounds such as three imidacloprid metabolites, 6-chloro nicot…
Environmental and food applications of LC-tandem mass spectrometry in pesticide-residue analysis: An overview
2003
An overview is given on pesticide-residue determination in environmental and food samples by liquid chromatography/mass spectrometry/mass spectrometry (LC/MS/MS). Pesticides comprise a large number of substances that belong to many completely different chemical groups, the only common characteristic is that they are effective against pests. They still constitute a challenge in MS because there is no collective pathway for fragmentation. A brief introduction to the theory of tandem MS permits a discussion of which parameters influence the ionization efficiency when the ions are subjected to different actions. Emphasis is placed on the different tandem MS instruments: triple and ion-trap quad…
Automated on-line in-tube solid-phase microextraction-assisted derivatization coupled to liquid chromatography for quantifying residual dimethylamine…
2008
Abstract A method for the analysis of dimethylamine (DMA) by automated in-tube solid-phase microextraction (IT-SPME)-supported chemical derivatization coupled with high-performance liquid chromatography was developed. Extraction, derivatization and desorption were studied by using a capillary coated with 95% polydimethylsiloxane and 5% polydiphenylsiloxane. Solution derivatization and automated IT-SPME derivatization using 9-fluorenylmethyl chloroformate (FMOC) were compared. The proposed procedure provided adequate linearity, accuracy and precision in the 0.2–2.0 μg/mL concentration interval, and the limit of detection (LOD) was 50 ng/mL. The main advantages of the proposed procedure are: …
Determination of hydroxylated benzophenone UV filters in sea water samples by dispersive liquid-liquid microextraction followed by gas chromatography…
2010
A new analytical method for the determination of four hydroxylated benzophenone UV filters (i.e. 2-hydroxy-4-methoxybenzophenone (HMB), 2,4-dihydroxybenzophenone (DHB), 2,2'-dihydroxy-4-methoxybenzophenone (DHMB) and 2,3,4-trihydroxybenzophenone (THB)) in sea water samples is presented. The method is based on dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography-mass spectrometry (GC-MS) determination. The variables involved in the DLLME process were studied. Under optimized conditions, 1000 microL of acetone (disperser solvent) containing 60 microL of chloroform (extraction solvent) were injected into 5 mL of aqueous sample adjusted to pH 4 and containing 10% NaCl…
Determination of type A trichothecenes by high-performance liquid chromatography with coumarin-3-carbonyl chloride derivatisation and fluorescence de…
2000
A method for the analysis of type A trichothecenes T-2 toxin, HT-2 toxin, neosolaniol and diacetoxyscirpenol by high-performance liquid chromatography with fluorescence detection using coumarin-3-carbonyl chloride has been developed. Different parameters concerning the analytical procedure such as stability of both the reagent and derivatised analytes, time and temperature of the derivatisation reaction, were studied and optimised. Three different clean-up procedures (solid-phase extraction with silica gel or C-18 cartridges, and liquid-liquid partition between toluene and dihydrogen phosphate buffer) were tested in order to remove the excess reagent peaks. The last procedure gave the best …
An environmentally friendly multicommutated alternative to the reference method for anionic surfactant determination in water
2004
Abstract It has been developed a fully mechanized procedure for the spectrophotometric determination of anionic surfactants in water expressed in terms of SDS concentration. The reference method, based on the reaction of SDS with methylene blue (MB) followed by extraction in chloroform, was mechanized in order to reduce the consumption of organic solvents. The system was based on the multicommutation approach and provided a 35 times reduction of the waste production without sacrificing the figures of merit of the method in terms of sensitivity and repeatability, for a dynamic linear range from 0.2 to 1.7 mg l−1. Results obtained for washing water samples were comparable with those obtained …
Improving detection limits for organotin compounds in several matrix water samples by derivatization-headspace-solid-phase microextraction and GC-MS.
2010
Triethyltin, tributyltin, diphenyltin and triphenyltin were selected as model compounds. The method is based on in situ ethylation and simultaneous headspace-solid-phase microextraction (HS-SPME) and gas chromatographic-mass spectrometry analysis (GC-MS). The extraction procedure was optimized studying some variables such as reaction time, salinity, sample volume and headspace volume. SPME-GC-MS and SPME-GC-FID techniques were compared; quality assurance parameters such as sensitivity, selectivity and precision were established. The proposed procedure showed limits of detection between 0.025 and 1 ng/L. The linearity was in the 0.025-5000 ng/L range. The precision expressed as relative stan…