Search results for "sample preparation"

showing 10 items of 343 documents

Validation of Powder X-Ray Diffraction Following EN ISO/IEC 17025

2012

:  Powder X-ray diffraction (PXRD) is used widely in forensic science laboratories with the main focus of qualitative phase identification. Little is found in literature referring to the topic of validation of PXRD in the field of forensic sciences. According to EN ISO/IEC 17025, the method has to be tested for several parameters. Trueness, specificity, and selectivity of PXRD were tested using certified reference materials or a combination thereof. All three tested parameters showed the secure performance of the method. Sample preparation errors were simulated to evaluate the robustness of the method. These errors were either easily detected by the operator or nonsignificant for phase iden…

Detection limitEngineeringCertified reference materialsbusiness.industryX-ray crystallographyGeneticsAnalytical chemistrySample preparationProficiency testbusinessISO/IEC 17025Powder diffractionPathology and Forensic MedicineJournal of Forensic Sciences
researchProduct

Minimizing the impact of sample preparation on analytical results: In-tube solid-phase microextraction coupled on-line to nano-liquid chromatography …

2020

The degradation kinetics and residual levels of the sulfonylurea herbicide tribenuron-methyl (TBM) in different environmental waters were studied using in tube-solid phase microextraction (IT-SPME) coupled on-line to nano-liquid chromatography (nanoLC) and UV diode array detection (DAD). This approach combines the high extraction efficiency of IT-SPME using polymeric coatings reinforced with metal oxide nanoparticles and the high sensitivity attainable by nanoLC, making possible the determination of TBM at low ppb levels (limit of detection, 0.25 ppb) without altering the sample matrix. The present study demonstrated that the preservation of the sample properties is essential to ensure accu…

Detection limitEnvironmental EngineeringChromatography010504 meteorology & atmospheric sciencesChemistryExtraction (chemistry)010501 environmental sciencesSolid-phase microextraction01 natural sciencesPollutionHydrolysisPhase (matter)Environmental ChemistryDegradation (geology)Tube (fluid conveyance)Sample preparationWaste Management and Disposal0105 earth and related environmental sciencesScience of The Total Environment
researchProduct

Analysis of Polycyclic Aromatic Hydrocarbons and Their Oxygen-Containing Derivatives and Metabolites in Soils

2010

Although polycyclic aromatic hydrocarbons (PAHs) have been extensively studied, the knowledge of their oxygen-containing derivatives and metabolites (OPAHs) in soils is limited. We modified and tested an existing analytical protocol involving pressurized liquid extraction of soil followed by fractionation of target compounds into PAHs and OPAHs on a silica gel column and gas chromatography/ mass spectrometry-based separation and quantification. Polycyclic aromatic hydrocarbons and carbonyl-OPAHs were quantified directly after separation on silica gel columns, and hydroxyl/carboxyl-OPAHs were quantified after silylation with N,O-bis(trimethylsilyl)trifluoroacetamide. Recoveries between 78 an…

Detection limitEnvironmental EngineeringChromatographyOpahbiologySilylationChemistrySilica gelExtraction (chemistry)Industrial WasteFractionationManagement Monitoring Policy and Lawbiology.organism_classificationPollutionOxygenSoilchemistry.chemical_compoundEnvironmental chemistrySoil PollutantsSample preparationGas chromatographyPolycyclic Aromatic HydrocarbonsWaste Management and DisposalEnvironmental MonitoringWater Science and TechnologyJournal of Environmental Quality
researchProduct

Flow injection Fourier transform infrared determination of caffeine in coffee

1999

Abstract A fully automatized procedure has been developed for the Fourier transform infrared (FT-IR) spectroscopic determination of caffeine in coffee samples. The method involves the on-line extraction of caffeine with CHCl3. Samples, weighed inside empty PTFE cartridges of 0.5 cm internal diameter (i.d.) and 1.5 ml volume, were humidified with four drops of 0.25 M NH3. The cartridge was installed in a flow manifold, in which samples were extracted in a closed-flow system with 1 ml CHCl3 during 6 min. Four hundred microliters of the extract were introduced in a microflow cell and absorbance measured as a function of time at 1659 cm−1, with a baseline established between 1900 and 830 cm−1, …

Detection limitFlow injection analysisChromatographyAnalytical chemistryStandard solutionAbsorbanceCartridgechemistry.chemical_compoundsymbols.namesakeFourier transformchemistrysymbolsSample preparationCaffeineSpectroscopyVibrational Spectroscopy
researchProduct

Zwitterionic Sulfonates as m/z Shift Reagents for 5-Methylcytosine Detection in Deoxyribonucleic Acids (DNA) Using Flow Injection Analysis and Electr…

2015

5-Methylcytosine (5-MC) is an important epigenetic modification of DNA. Abnormally high concentrations of this substance appear because of the hypermethylation of cytosine. Therefore, the measurement of the quantity of this compound in mammals is of great importance. Recently, we reported that several imidazolium-based zwitterionic sulfonates form complexes with 5-MC in solution, which can be studied by electrospray ionisation mass spectrometry (ESI-MS). It is shown in this paper that such an association can be utilised for the detection of 5-MC in a DNA sample using high-throughput a flow injection analysis ESI-MS method. A variety of the sulfonate zwitterions have been tested as m/ z shi…

Detection limitFlow injection analysisSpectrometry Mass Electrospray IonizationElectrosprayChromatographyChemistryElectrospray ionizationAnalytical chemistryReproducibility of ResultsDNAGeneral MedicineDNA MethylationTandem mass spectrometryMass spectrometryAtomic and Molecular Physics and OpticsSample preparation in mass spectrometryFlow Injection Analysis5-MethylcytosineAnimalsCattleA-DNASulfonic AcidsSpectroscopyEuropean Journal of Mass Spectrometry
researchProduct

Liquid chromatographic determination of trimethylamine in water.

2004

A method for the selective determination of trimethylamine (TMA) in aqueous matrices by liquid chromatography is reported. The proposed procedure is based on the derivatization of the analyte with 9-fluorenylmethyl chloroformate (FMOC) in a precolumn (Hypersil C18, 30 microm, 20 mm x 2.1 mm i.d.) connected on-line to the analytical column (LiChrosphere 100 RP18, 5 microm, 125 mm x 4 mm i.d.). Gradient elution was performed with a mixture of acetonitrile-water-0.05 M borate buffer (pH 9.0). The method has been applied to the direct determination of TMA in water within the 0.25-10.0 microg/ml concentration interval, and can also be adapted to the determination of TMA over the range 0.05-1.0 m…

Detection limitFluorenesChromatographyTertiary amineChemistryOrganic ChemistryWaterTrimethylamineGeneral MedicineReversed-phase chromatographyChloroformateSensitivity and SpecificityBiochemistryAnalytical ChemistryMethylamineschemistry.chemical_compoundSample preparationSolid phase extractionDerivatization
researchProduct

Improvement of the electrophoretic protein profiles of Leguminosae gums extracts using gamanase and application to the evaluation of carob–guar mixtu…

2004

Abstract A quantitative assay for guar gum in carob gum, based on the extraction of proteins in acetonitrile–water (7:3), separation by capillary electrophoresis and multiple linear regression (MLR) using the areas of nine selected peaks as predictors, was improved by performing the extraction in the presence of gamanase. In the absence of the enzyme, peak migration times and areas depended on the guar content, which complicated peak identification and evaluation. Manual correction of the migration times by comparison with standard electropherograms obtained with pure carob and carob–guar mixtures was required; however, when the proteins were extracted under sonication at 60 °C for 30 min i…

Detection limitGuar gumChromatographyChemistrySonicationExtraction (chemistry)GuarBiochemistryAnalytical ChemistryElectrophoresisCapillary electrophoresisEnvironmental ChemistrySample preparationSpectroscopyAnalytica Chimica Acta
researchProduct

Determination of organophosphorus pesticides in honeybees after solid-phase microextraction.

2001

A method based on solid-phase microextraction (SPME) followed by gas chromatography with nitrogen-phosphorus detection was developed for the purpose of determining 18 organophosphorus pesticide residues in honeybee samples (Apis mellifera). The extraction capacities of polyacrylate and poly(dimethylsiloxane) fibers were compared. The main factors affecting the SPME process, such as the absorption time profile, salt, and temperature, were optimized. The method involved honeybee sample homogenization, elution with an acetone:water solution (1:1) and dilution in water prior to fiber extraction. Moreover, the matrix effect on the extraction was evaluated. In samples spiked at the 0.2 mg kg(-1) …

Detection limitInsecticidesChromatographyChemistryElutionOrganic ChemistryExtraction (chemistry)Osmolar ConcentrationTemperatureGeneral MedicineBeesSolid-phase microextractionBiochemistrySensitivity and SpecificityAnalytical ChemistryDilutionOrganophosphorus CompoundsSolventsAnimalsSample preparationSaltsSolid phase extractionGas chromatographyJournal of chromatography. A
researchProduct

Optimization of sample preparation conditions for detecting trace amounts of β-tegafur in α- and β-tegafur mixture.

2012

We report a semiquantitative method for determining trace amounts (<1%) of thermodynamically stable forms in polymorphic mixtures, focusing on sample preparation ef- fects on solid phase transitions. Tegafur (5-fluoro-1-(oxolan-2-yl)-1,2,3,4-tetrahydropyrimidine- 2,4-dione) was used as a model material in this study. The amounts of the thermodynamically stable $ tegafur were increased to levels detectable by powder X-ray diffractometry by grind- ing the samples in a ball mill in the presence of water. The limit of detection for this method was as low as 0.0005% of $ tegafur in " and $ tegafur mixtures. The amount of $ tegafur after sample preparation was found to be proportional to the init…

Detection limitLangmuirAntimetabolites AntineoplasticTrace AmountsChemistryAnalytical chemistryPharmaceutical ScienceTegafurPhase TransitionPolymorphism (materials science)IsomerismX-Ray DiffractionLimit of DetectionmedicineThermodynamicsSample preparationBall millMass fractionPowder Diffractionmedicine.drugTegafurJournal of pharmaceutical sciences
researchProduct

Multi-element trace determinations in pure alkaline earth fluoride powders by high-resolution ICP-MS using wet-chemical sample preparation and laser …

2003

Four alternative analytical procedures for the determination of ten important trace impurities (Mg, Cr, Fe, Cu, Zn, Sr, Zr, Cd, Ba, and Pb) in pure alkaline earth fluoride powders were applied using high-resolution inductively coupled plasma mass spectrometry (ICP-MS). Two procedures are based on a wet-chemical microwave digestion with boric acid and quantification by the standard addition technique and isotope dilution mass spectrometry (IDMS), respectively. In addition, analyses are also performed by laser ablation as a direct solid sampling technique applying matrix-matched external calibration as well as isotope dilution of the powdered sample. For most elements good agreement between t…

Detection limitLaser ablationChemistryStandard additionAnalytical chemistryAnalytical proceduresSample preparationIsotope dilutionMicrowave digestionBiochemistryInductively coupled plasma mass spectrometryAnalytical ChemistryAnalytical and bioanalytical chemistry
researchProduct