Search results for "sanitari"

showing 10 items of 639 documents

A QUANTITY-QUALITY MATHEMATICAL MODEL FOR MUNICIPAL SOLID WASTE LANDFILL: MODEL CALIBRATION AND SENSITIVITY ANALYSIS

2015

Landfill leachate represents nowadays one of the most important issue related to the waste management cycle. Knowledge about leachate distribution and transport as well as fate of pollutants is fundamental for understanding the behavior of the landfill reactor. In the present study, a simple 1-D mathematical model was developed for the simulation of the vertical leachate fluxes throughout a landfill for MSW as well as the fate of inorganic pollutants within the landfill leachate pathway. The model was based on mass balance equations, which allowed to evaluate the moisture accumulation inside the landfill body as well as contaminant transport processes. The model enables to calculate the moi…

Mathematical modelSettore ICAR/03 - Ingegneria Sanitaria-Ambientalefate of inorganic pollutantsleachate distribution
researchProduct

Greenhouse gas emissions from integrated urban drainage systems: where do we stand?

2018

As sources of greenhouse gas (GHG) emissions, integrated urban drainage systems (IUDSs) (i.e., sewer systems, wastewater treatment plants and receiving water bodies) contribute to climate change. This paper, produced by the International Working Group on Data and Models, which works under the IWA/IAHR Joint Committee on Urban Drainage, reviews the state-of-the-art and modelling tools developed recently to understand and manage GHG emissions from IUDS. Further, open problems and research gaps are discussed and a framework for handling GHG emissions from IUDSs is presented. The literature review reveals that there is a need to strengthen already available mathematical models for IUDS to take …

Mathematical modellingSettore ICAR/03 - Ingegneria Sanitaria-Ambientale0208 environmental biotechnologyEnvironmental engineeringClimate change02 engineering and technology010501 environmental sciencesInternational working group01 natural sciences020801 environmental engineeringWater quality/dk/atira/pure/sustainabledevelopmentgoals/climate_actionGreenhouse gasSDG 13 - Climate ActionEnvironmental scienceIntegrated urban drainage modellingSewage treatmentGHGWater qualityDrainage0105 earth and related environmental sciencesWater Science and Technology
researchProduct

Global sensitivity analysis for urban water quality modelling: Terminology, convergence and comparison of different methods

2015

Abstract Sensitivity analysis represents an important step in improving the understanding and use of environmental models. Indeed, by means of global sensitivity analysis (GSA), modellers may identify both important ( factor prioritisation ) and non-influential ( factor fixing ) model factors. No general rule has yet been defined for verifying the convergence of the GSA methods. In order to fill this gap this paper presents a convergence analysis of three widely used GSA methods (SRC, Extended FAST and Morris screening) for an urban drainage stormwater quality–quantity model. After the convergence was achieved the results of each method were compared. In particular, a discussion on peculiar…

Mathematical optimizationMathematical modelSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleUncertaintyContrast (statistics)Numerical method6. Clean waterTerm (time)law.inventionSystems analysisMathematical modelMathematical models; Numerical methods; Sewer sediments; Systems analysis; Uncertainty; Urban drainage modelling; Water Science and TechnologySystems analysilawSewer sedimentConvergence (routing)StatisticsVenn diagramSensitivity (control systems)Urban drainage modellingReliability (statistics)MathematicsWater Science and Technology
researchProduct

Uncertainty Propagation in Integrated Urban Water Quality Modelling

2018

Sensitivity and uncertainty assessment of integrated urban drainage water quality models are crucial steps in the evaluation of the reliability of model results. Indeed, the assessment of the reliability of the results of complex water quality models is crucial in understanding their significance. In the case of integrated urban drainage water quality models, due to the fact that integrated approaches are basically a cascade of sub-models (simulating the sewer system, wastewater treatment plant and receiving water body), uncertainty produced in one sub-model propagates to the following ones in a manner dependent on the model structure, the estimation of parameters and the availability and u…

Mathematical optimizationPropagation of uncertaintySettore ICAR/03 - Ingegneria Sanitaria-AmbientaleComputer scienceStandard deviationpollution evaluationKeywords: Integrated urban drainage modelling Environmental water quality management Pollution evaluation Uncertainty analysisIntegrated urban drainage modellingSensitivity (control systems)Water qualityDrainageGLUEuncertainty analysisenvironmental water quality managementUncertainty analysisReliability (statistics)
researchProduct

Global sensitivity analysis in wastewater treatment modelling

2019

Global sensitivity analysis (GSA) is a valuable tool to support the use of mathematical models. GSA allows the identifcation of the effect of model and input factor uncertainty on the model response, also considering the effect due to the interactions among factors. During recent years, the wastewater modelling feld has embraced the use of GSA. Wastewater modellers have tried to transfer the knowledge and experience from other disciplines and other water modelling felds.

Mathematical optimizationSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleComputational burden convergence modelling numerical methods sensitivity analysis water modellingGlobal sensitivity analysisNumerical analysisConvergence (routing)Sewage treatmentMathematics
researchProduct

La sopravvivenza immediata delle start-up italiane del settore manifatturiero sanitario: un'analisi multilevel

2017

The immediate survival of the Italian start-up businesses in healthcare industry: a multilevel analysis Objectives: The purpose of this contribution is to provide novel evidence about the main determinants of the short-run survival of pharmaceutical and medical device manufacturing start-up firms in Italy. In order to assess both the firm-specific determinants and the observed and unobserved regional and contextual characteristics, we model the three-year firm survival probability by means of a multilevel logistic framework. Methods and Results: The empirical analysis focuses on an internationally comparable database of the population of firms built up and managed by the Italian National In…

Medical devicedemografia d’impresa sopravvivenza delle imprese modellistica logit multi- level metodo dell’entropia relativa imprese start-upfirm demographyPopulationcross-entropy methodmetodo dell’entropia relativaLogistic regressionmultilevel logistic modellingstart-up firmsSurvival probabilityimprese start-upOrder (exchange)EconometricseducationProductivityGeneral Environmental ScienceEstimationeducation.field_of_studysopravvivenza delle impresefirm survivaldemografia d’impresaRandom effects modelStar-up Settore Sanitario Modelli Multilevel Italiamodellistica logit multi- levelfirm demography firm survival multilevel logistic modelling cross-entropy method start-up firmsSettore SECS-S/03 - Statistica EconomicaGeneral Earth and Planetary SciencesBusiness
researchProduct

El estudio PROPRESE: resultados de un nuevo modelo organizativo en atención primaria para pacientes con cardiopatía isquémica crónica basado en una i…

2014

ResumenObjetivoComparando los resultados obtenidos en los estudios EUROASPIRE I y EUROASPIRE III en pacientes con cardiopatía isquémica se muestra que el grado de control de los factores de riesgo mayores es mejorable. El objetivo de este estudio es evaluar la eficacia de una intervención multifactorial orientada a la mejora del grado de control en estos pacientes en el ámbito de la atención primaria.MétodosEn este estudio de intervención aleatorizado, con 1 año de seguimiento, se reclutó a pacientes con diagnóstico de cardiopatía isquémica (145 en el grupo de intervención y 1.461 en el grupo control). Se aplicó una intervención organizativa mixta basada en la mejora de la relación profesio…

Medicine(all)lcsh:R5-920Cardiovascular diseasesSecondary preventionPrevención secundariaHealth services researchInvestigación en servicios sanitariosGeneral MedicineEnfermedades cardiovascularesPrimary careFamily PracticeAtención primarialcsh:Medicine (General)Atención Primaria
researchProduct

Oil-degrading bacteria from a membrane bioreactor (MBR) system for treatment of saline oily waste: isolation, identification and characterization of …

2015

This study was focused on the microbial community characterization during operation of a Membrane Bioreactor System, used for the treatment of saline oily wastes, originated from marine transportation. A collection of forty-two (42) strains was obtained during microbiological screening and the bacterial diversity analyzed by amplification and 16S rRNA sequencing. Taxonomic analysis has shown a high level of identity with recognized sequences for a total of seven (7) distinct bacterial genera (Alcanivorax, Erythrobacter, Marinobacter, Microbacterium, Muricauda, Rhodococcus and Rheinheimera). The biotechnological potential of all isolates was identified by the estimate of two key factors, suc…

Membrane Bioreactor SystemSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleAlcanivoraxsaline oily wastesSettore BIO/19 - Microbiologia Generale
researchProduct

Application of the Oxic-Settling-Anaerobic Process in a Membrane Bioreactor for Excess Sludge Reduction

2017

The main goal of this study was the evaluation of the excess sludge reduction in a MBR for biological nitrogen removal (BNR) through the implementation of the Oxic-Settling-Anaerobic (OSA) process. For this purpose, a MBR pilot plant (42 L volume) was realized according to a pre-denitrification scheme. The whole experimentation was divided into two periods, named Period 1 and Period 2, respectively. In Period 1 the pilot plant was started-up and the excess sludge production was evaluated. In Period 2 the plant configuration was partially modified by inserting an anaerobic reactor into the return activated sludge (RAS) line to realize an OSA configuration. In Period 1, the Yobs resulted equa…

Membrane bioreactor Excess sludge minimization OSAAnaerobic respirationPilot plantActivated sludgeSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleVolume (thermodynamics)SettlingChemistryHeterotrophBiomassMembrane bioreactorPulp and paper industry
researchProduct

Minimizing membrane bioreactor environmental footprint by multiple objective optimization.

2020

This paper presents a modelling study aimed at minimizing the environmental foot print of a membrane bioreactor (MBR) for wastewater treatment. Specifically, an integrated model for MBR was employed in view of the management optimization of an MBR biological nutrient removal (BNR) pilot plant in terms of operational costs and direct greenhouse gases emissions. The influence of the operational parameters (OPs) on performance indicators (PIs) was investigated by adopting the Extended-FAST sensitivity analysis method. Further, a multi-objective analysis was performed by applying the Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS). The results show-up that the sludge …

Membrane fouling0106 biological sciencesEnvironmental EngineeringWastewater treatment plantMathematical modelling optimizationBioengineeringWastewater010501 environmental sciencesMembrane bioreactor01 natural sciencesWaste Disposal FluidGreenhouse GasesBioreactors010608 biotechnologyWaste WaterProcess engineeringWaste Management and Disposal0105 earth and related environmental sciencesSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleSewageRenewable Energy Sustainability and the Environmentbusiness.industryMembrane foulingTOPSISMembranes ArtificialGeneral MedicineIdeal solutionPilot plantGreenhouse gasMulti-objective analysisEnvironmental scienceSewage treatmentPerformance indicatorbusinessBiotechnology
researchProduct