Search results for "scattered"
showing 5 items of 15 documents
A method of evaluation of measured light intensities and degrees of polarization of a unit volume of turbid air
1965
In order to interpret scattered light measurements a comparison with theoretical values is necessary. It is demonstrated by means of an example the possibility to obtain a first view on the measurement results. From calculated values of various aerosol size distribution models as well as from measurements were computed: 1) the angular quotients of scattered light intensity (i.e., quotients of intensity at two scattering angles and the same wavelength) and 2) the wavelength quotients (i.e., quotients of intensity at two wavelengths and the same scattering angle). The comparison between measured and theoretical values informs us of the exponent of the aerosol size distribution and its boundar…
Electron Emission of Pt: Experimental Study and Comparison With Models in the Multipactor Energy Range
2016
Experimental data of secondary emission yield (SEY) and electron emission spectra of Pt under electron irradiation for normal incidence and primary energies lower than 1 keV are presented. Several relevant magnitudes, as total SEY, elastic backscattering probability, secondary emission spectrum, and backscattering coefficient, are given for different primary energies. These magnitudes are compared with theoretical or semiempirical formulas commonly used in the related literature.
Disentangling scattered charcoal assemblages for palimpsest dissection: Spatial analyses from El Salt Stratigraphic Unit Xb (Eastern Iberia)
2017
International audience; Disentangling scattered charcoal assemblages for palimpsest dissection: spatial analyses from El Salt Stratigraphic unit Xb (Eastern Iberia)
Fracture Shape and Orientation Contributions to P-Wave Velocity and Anisotropy of Alpine Fault Mylonites
2021
P-wave anisotropy is significant in the mylonitic Alpine Fault shear zone. Mineral- and texture-induced anisotropy are dominant in these rocks but further complicated by the presence of fractures. Electron back-scattered diffraction and synchrotron X-ray microtomography (micro-CT) data are acquired on exhumed schist, protomylonite, mylonite and ultramylonite samples to quantify mineral phases, crystal preferred orientations, microfractures and porosity. The samples are composed of quartz, plagioclase, mica and accessory garnet, and contain 3-5% porosity. Based on the micro-CT data, the representative pore shape has an aspect ratio of 5:2:1. Two numerical models are compared to calculate the…
1973
The direct and the inverse problem of the light scattering from dilute polymer solutions is solved for GAUssian coils at the theta point. Theoretical scattering functions and their derivatives are analytically calculated for the general gamma distribution of molecular weights as a function of the non-uniformity and the weight average molecular weight, and also for various ratios of the statistical segment length of the coil to the wave length of the scattered light. The asymptote and the tangent of P are obtained by analysing the operator in the ZIMM equation and their mutual position is compared in the angle range 150° to 180°. The scattering envelopes of microgel systems are analytically …