Search results for "sens"

showing 10 items of 13828 documents

Circular RNA in Exosomes

2018

Circular RNAs (circRNAs) are a novel family of non-coding endogenous RNAs discovered in all eukaryotic cells and generated through a particular mechanism of alternative splicing called “back-splicing”. These molecules show multiple functions, by acting as modulators of gene and miRNA expression, and may have a role in several biological processes, such as cell proliferation and invasion with, tumour development and progression, and in several mechanisms underlying other diseases. Their presence has been shown to be abundant in several body fluids such as blood and saliva. Based on their biogenesis mechanism, cir- cRNAs may be categorized into five classes: exonic circRNAs, intronic circRNAs…

(circRNAs)0301 basic medicineSettore MED/06 - Oncologia MedicaAlternative splicingBiomarkerCDR1asBiologyExosomesExosomeNon-coding RNAsMicrovesiclesCell biology03 medical and health sciences030104 developmental biologyCircular RNAmicroRNASense (molecular biology)Circular RNAGeneBiogenesis
researchProduct

Foreign language learning in multilingual Germany

2021

This special issue on foreign language (FL) learning in multilingual contextsprovides insights into cross- and inter-linguistic phenomena comparingmonolingual and multilingual students who learn FLs in linguistically het-erogeneous classrooms. All contributions are based on data gathered in pro-jects carried out within the research cluster “Language education andmultilingualism”/“Sprachliche Bildung und Mehrsprachigkeit”, which hasbeen funded by the German Federal Ministry for Education and Research(Bundesministerium für Bildung und Forschung, BMBF) from 2013 to 2020. Bybringing together linguistic and educational perspectives on FL learning andteaching as well as different methodological a…

/dk/atira/pure/core/keywords/sprachwissenschaftenLinguistics and LanguageForeign language learningLanguage StudiesCommunicationPsychologyLanguage and LinguisticsLinguisticsMultilingua
researchProduct

Injection and ultrafast regeneration in dye-sensitized solar cells

2014

Injection of an electron from the excited dye molecule to the semiconductor is the initial charge separation step in dye-sensitized solar cells (DSC's). Though the dynamics of the forward injection process has been widely studied, the results reported so far are controversial, especially for complete DSC's. In this work, the electron injection in titanium dioxide (TiO2) films sensitized with ruthenium bipyridyl dyes N3 and N719 was studied both in neat solvent and in a typical iodide/triiodide (I-/I3 -) DSC electrolyte. Transient absorption (TA) spectroscopy was used to monitor both the formation of the oxidized dye and the arrival of injected electrons to the conduction band of TiO2. Emiss…

/dk/atira/pure/sustainabledevelopmentgoals/affordable_and_clean_energyta221Analytical chemistrychemistry.chemical_elementElectrolyteNanosecondPhotochemistrySurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsRutheniumDye-sensitized solar cellchemistry.chemical_compoundGeneral EnergychemistryPicosecondTitanium dioxideUltrafast laser spectroscopySDG 7 - Affordable and Clean EnergyPhysical and Theoretical ChemistryTriiodideta116
researchProduct

The effects of environment on Arctica islandica shell formation and architecture

2017

Mollusks record valuable information in their hard parts that reflect ambient environmental conditions. For this reason, shells can serve as excellent archives to reconstruct past climate and environmental variability. However, animal physiology and biomineralization, which are often poorly un- derstood, can make the decoding of environmental signals a challenging task. Many of the routinely used shell-based proxies are sensitive to multiple different environmental and physiological variables. Therefore, the identification and in- terpretation of individual environmental signals (e.g., water temperature) often is particularly difficult. Additional prox- ies not influenced by multiple enviro…

/dk/atira/pure/sustainabledevelopmentgoals/life_below_waterlcsh:Geologylcsh:QH501-531550 Earth scienceslcsh:QH540-549.5lcsh:QE1-996.5lcsh:Lifelcsh:EcologySDG 14 - Life Below Water550 Geowissenschaften
researchProduct

Generalised bisection method for optimum ultrasonic ray tracing and focusing in multi-layered structures

2021

Ultrasonic testing has been used for many decades, proving itself very efficient for detecting defects in many industrial sectors. The desire to apply ultrasonic testing to geometrically complex structures, and to anisotropic, inhomogeneous materials, together with the advent of more powerful electronics and software, is constantly pushing the applicability of ultrasonic waves to their limits. General ray tracing models, suitable for calculating the proper incident angle of single element probes and the proper time delay of phased array, are currently required. They can support the development of new imaging techniques, as Full Matrix Capture and Total Focusing Method, and the execution of …

010302 applied physicsAcoustics and UltrasonicsComputer scienceIterative methodbusiness.industryTKComputationUltrasonic testing01 natural sciencesRay tracing (physics)Settore ING-IND/14 - Progettazione Meccanica E Costruzione Di MacchineSoftware0103 physical sciencesBisection methodUltrasonic wave propagation Ray tracing Mathematical modelling Bisection method Multi-layered structures Weld inspection CompositesA priori and a posterioriUltrasonic sensorbusiness010301 acousticsAlgorithmUltrasonics
researchProduct

A combined three-dimensional digitisation and subsurface defect detection data using active infrared thermography

2016

International audience; In recent years, NonDestructive Testing (NDT) systems have been upgraded with three-dimensional information. Indeed, combine the three-dimensional and thermal information allows a more meaningful analysis. In the literature, the data for NDT and three-dimensional (3D) reconstruction analysis are commonly acquired from independent systems. However, the use of two such systems leads to error analysis during the data registration. In an attempt to overcome such problems, we propose a single system based on active thermography approach using heat point-source stimulation to get the 3D digitization as well as subsurface defect detection. The experiments are conducted on s…

010302 applied physicsActive infraredbusiness.industryComputer science[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processing01 natural sciencesError analysisNondestructive testing0103 physical sciencesThermographyData registrationbusiness[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing010301 acousticsDigitization[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processingRemote sensing
researchProduct

Optimum Design and Performance of an Electron Gun for a Ka-Band TWT

2019

This paper deals with optimum design and development of a thermionic electron gun to meet specified beam requirements within defined electric and geometric constraints for a Ka -band traveling wave tube (TWT) for space applications. The electron gun design is based on the Pierce method and carried out according to the iterative process indicated by Vaughan. The design of a periodic permanent magnet (PPM) beam focusing system for the stability of the beam is also required. A sensitivity analysis, by varying electric parameters and geometric parameters, is presented and taken into account as a fundamental role to the aim of optimizing the design of the Pierce gun. A cathode current value of 5…

010302 applied physicsBeam diameterMaterials sciencebusiness.industryTraveling-wave tubeSettore ING-INF/01 - Elettronica01 natural sciencesCathodeElectronic Optical and Magnetic Materialslaw.inventionSettore ING-IND/31 - ElettrotecnicaOpticslawcontrol grid electron gun PPM focusing system sensitivity analysis shadow grid TWTMagnet0103 physical sciencesKa bandElectrical and Electronic EngineeringbusinessBeam (structure)VoltageElectron gunIEEE Transactions on Electron Devices
researchProduct

A Novel Method for Characterizing Temperature Sensitivity of Silicon Wafers and Cells

2019

In this paper, we present a novel method to obtain temperature dependent lifetime and implied-open-circuit voltage (iV OC ) images of silicon wafers and solar cells. First, the method is validated by comparing the obtained values with global values acquired from lifetime measurements (for wafers) and current-voltage measurements (for cells). The method is then extended to acquire spatially resolved images of iV OC temperature coefficients of silicon wafers and cells. Potential applications of the proposed method are demonstrated by investigating the temperature coefficients of various regions across multi-crystalline silicon wafers and cells from different heights of two bricks with differe…

010302 applied physicsBrickTemperature sensitivityMaterials sciencebusiness.industry02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesReduced propertiesImpurity0103 physical sciencesOptoelectronicsWaferSensitivity (control systems)Dislocation0210 nano-technologybusinessVoltage2019 IEEE 46th Photovoltaic Specialists Conference (PVSC)
researchProduct

Partial discharges behavior under different rectified waveforms

2017

In this work, a previous software used to simulate partial discharges (PDs) under Alternating Current (AC) stress has been modified in order to evaluate the PDs behavior under a voltage stress close to the Direct Current (DC) waveform. By using a full-wave and a half-wave rectifier, the specimen with an air void defects has been subjected to a gradual constant stress. Finally, a capacitive filter has been inserted in order to produce a steadier voltage supply. Simulation results show that under an almost DC waveform, the PDs activity become less compared to AC stress.

010302 applied physicsDC stressMaterials scienceHVDCPD modelbusiness.industryAcousticsCapacitive sensingDirect currentElectrical engineeringRectified waveform01 natural sciencesSpace charge010305 fluids & plasmaslaw.inventionStress (mechanics)RectifierSettore ING-IND/31 - Elettrotecnicalaw0103 physical sciencesWaveformPartial DischargebusinessAlternating currentVoltage
researchProduct

Analog isolated electronic dynamometer based on a magnetoresistive current sensor.

2017

In this work, an electronic system is presented to measure the force applied by a solenoid. The originality of the work is focused on the use of a magnetoresistive current sensor to provide the isolation barrier needed in the actual industrial plant where the solenoids are working. The design of the electronic system is presented as well as experimental measurements as a result of a calibration process showing a negligible hysteresis with that specific sensor. The magnetoresistive current sensor is used to develop transmission functions rather than playing its usual sensing roles.

010302 applied physicsDynamometerMagnetoresistancebusiness.industryComputer science010401 analytical chemistryElectrical engineeringProcess (computing)Solenoid01 natural sciences0104 chemical sciencesHysteresisNuclear magnetic resonanceTransmission (telecommunications)0103 physical sciencesCalibrationCurrent sensorbusinessInstrumentationThe Review of scientific instruments
researchProduct