Search results for "sensitivity and specificity"
showing 10 items of 1080 documents
Plain film, CT and MRI sensibility in the evaluation of intraorbital foreign bodies in an in vitro model of the orbit and in pig eyes.
2000
Detection and characterization of intraorbital foreign bodies (IFB) is fundamental in acute trauma setting, preventing inflammatory sequelae or complications related to IFB movements when a MRI study is planned. Papers concerning plain film and CT sensibility in IFB detection show controversial results. For this reason we investigated plain film, CT and MRI sensibility in the evaluation of IFB. For an in vitro model, specimens of dry and fresh wood, glass, iron, plastic and graphite were immersed in animal lard and in a 0.9 % sodium chloride plus 3.5 g/dl human serum albumin solution. Specimens of different size and nature where also implanted into enucleated pig eyes. Air bubbles were intr…
Imaging of Ventriculoperitoneal Shunt Complications: Comparison of Whole Body Low-Dose Computed Tomography and Radiographic Shunt Series.
2016
OBJECTIVE To determine diagnostic value and radiation exposure of low-dose computed tomography (LD-CT) compared to radiographic shunt series (SS) for the detection of ventriculoperitoneal (VP) shunt complications. METHODS Fourteen VP shunts were implanted in 7 swine cadavers. Mechanical complications were induced in 50% of VP shunts. Low-dose CT (80 kVp, 10 mAs, Pitch = 1.5) and SS were acquired. Dose area product (DAP) and effective doses for SS and LD-CT were collected. Scoring of diagnostic confidence and blinded readings of SS and CT data were performed. RESULTS The sensitivity of LD-CT was high (0.97; 95% confidence interval, 0.91-1.00) with excellent interobserver agreement (κ = 0.88)…
Accuracy of automatic airway morphometry in computed tomography-correlation of radiological-pathological findings.
2010
Abstract Objectives Airway morphology shows characteristic changes in different pathologies. This study assesses the accuracy of a current automatic airway assessment technique by correlating CT images of porcine airways to histological slices of the same localization. Materials and methods Four isolated and ventilated porcine lungs were frozen in a liquid nitrogen bath and examined with a CT scanner (MDCT). This technique both preserved normal radiomorphological appearance and made it possible to slice the specimens for histological examination for subsequent correlation. The parameters wall thickness (WT), wall percentage (WP), and total diameter (TD) were assessed by computer-aided measu…
Value of routine abdominal and lymph node sonography in the follow-up of breast cancer patients.
1994
Abstract Objective: The aim of this study was to review usefulness and intervals for abdominal sonography during the follow-up of breast cancer patients. Additionally, we assessed the value of regional lymph node sonography in patients with possible locoregional recurrence. Subjects: Retrospectively, 2657 abdominal ultrasound examinations of 414 patients and 299 sonographic examinations of the regional lymph nodes in 227 patients after surgical treatment for breast cancer were evaluated. Results: Follow-up abdominal sonography revealed metastases in 6.8% of patients, and in 1% of examinations. There was no dependence on the initial T- or N-stage. At sonography of the regional lymph nodes in…
Prospective comparison of CT angiography of the legs with intraarterial digital subtraction angiography.
1996
The aim of this study was to determine the accuracy of CT angiography (CTA) with a single spiral acquisition for the diagnosis of arterial stenoses and occlusion in patients with peripheral vascular occlusive disease.In a prospective study, intraarterial digital subtraction angiography and i.v. CTA from the groin to the lower calves were performed on 50 patients with vascular occlusive disease. Maximum-intensity-projection images in multiple views were produced. The accuracy of CTA with and without analysis of the axial scans was determined with digital subtraction angiography as the standard.The sensitivities of CTA were 100% for the diagnosis of femoral artery occlusion, 100% for the dete…
D-dimer testing: advantages and limitations in emergency medicine for managing acute venous thromboembolism
2007
Patients with suspected deep vein thrombosis (DVT) or pulmonary embolism (PE) are frequently admitted to an Emergency Department (ED) for initial evaluation. However, management of patients with suspicion of acute venous thromboembolism (VTE) in this clinical setting can be difficult; in fact symptoms and signs of DVT are non-specific and can be found in a broad spectrum of non-thrombotic disorders. An accurate and timely objective diagnosis is necessary for immediate and correct identification of patients with acute VTE, while avoiding the bleeding risk associated with unnecessary anticoagulant therapy in patients where DVT or PE have been ruled out. The diagnostic approach to patients wit…
Recurrence quantification analysis as a tool for complex fractionated atrial electrogram discrimination
2012
International audience; Atrial fibrillation is the most encountered pathology of the heart rate. The reasons of its occurrence and its particular characteristics remain unknown, resulting from complex phenomena interaction. From these interactions emerges Complex Fractionated Atrial Electrograms (CFAE) which are useful for the ablation procedure. This study presents a method based on nonlinear data analysis, the Recurrence Quantification Analysis (RQA) applied on intracardiac atrial electrograms to detect CFAE particularities. The results obtained on areas previously tagged by a cardilogist show a good sensitivity to CFAE. Combination of RQA features offers a larger discrimination potential…
Sentinel-node biopsy in early stage ovarian cancer: a prospective multicentre study (SELLY)
2019
BackgroundSystematic para-aortic and bilateral pelvic lymphadenectomy is included in the standard comprehensive surgical staging in presumed early epithelial ovarian cancer. No prospective randomized evidence suggests it has potential therapeutic value, and related morbidity is not negligible.Primary Objective(s)To assess sensitivity, safety, and feasibility of the sentinel lymph node technique in identifying the presence of lymph node metastases in patients with early stage epithelial ovarian cancer.Study HypothesisSentinel lymph node detection with indocyanine green can accurately predict nodal status in a cohort of women with early stage epithelial ovarian cancer.Trial DesignThe SELLY tr…
Leg extension power asymmetry and mobility limitation in healthy older women
2005
Objective To investigate the association of asymmetry in leg extension power (LEP) with walking and standing balance. Design Cross-sectional analysis. Setting Research laboratory. Participants Healthy female twins (N=419), ages 63 to 75 years. Interventions Not applicable. Main Outcome Measures The LEP difference between the stronger and the weaker leg, measured with the Nottingham power rig, was calculated. Ten-meter maximal walking velocity was assessed in a laboratory corridor on a wide (170cm) and narrow (35cm) track, and the ability to maintain tandem stance for 20 seconds was recorded. Results The mean LEP difference ± standard deviation between the legs was 15%±9% (P<.001). Those wit…
Diagnosis of Endometrial Carcinoma: Predictive Value of Transvaginal Color Doppler
1995
The objective of this study was to determine whether transvaginal ultrasound plus color Doppler flow improve the ability to diagnose endometrial carcinoma and allow better discrimination between benign and malignant endometrial lesions. One hundred thirty women with abnormal uterine bleeding were evaluated with transvaginal color Doppler before fractional dilatation and curettage (D&C). The endometrial line thickness and endometrial characteristics were evaluated by endosonography. The resistive and pulsatile indices of the uterine arteries and of the endometrium were evaluated with transvaginal color Doppler. Following D&C and tissue diagnosis, women were divided into two groups, 62 with a…