Search results for "sensory system"
showing 10 items of 1266 documents
Evaluation of the practicality of optical biometry and applanation ultrasound in 253 eyes
2003
Abstract Purpose To evaluate the percentage of eyes that could not be measured using optical biometry and ultrasound applanation and the reasons. Setting Department of Ophthalmology, Johannes Gutenberg-University Hospital, Mainz, Germany. Methods Optical biometry (IOLMaster®, Carl Zeiss Meditec AG) and A-scan ultrasound biometry were performed consecutively in 253 eyes scheduled for cataract surgery the next day. Lens opacities were evaluated with the Opacity Lensmeter (Interzeag), and a slitlamp examination and measurement of visual acuity were performed. The 2 techniques were compared in terms of the rate of and reasons for primary measurement failure. Results Measurement with the IOLMast…
Thalamic infarctions cause side-specific suppression of vestibular cortex activations.
2005
H2O15-PET was performed during caloric vestibular stimulation of the right and left external ears in eight right-handed patients with acute unilateral infarctions or haemorrhages of the posterolateral thalamus (four right, four left). The posterolateral thalamus is the relay station for ipsi- and contralateral ascending vestibular input to the multiple multisensory vestibular cortex areas. The aim of this study was to evaluate the differential effects of unilateral vestibular thalamic lesions on thalamo-cortical projections, right hemispheric dominance and reciprocal inhibitory visual-vestibular interaction, as well as perceptual and ocular motor consequences during caloric irrigation. The …
Postural equilibrium: functional system and its stabilization by means of osteoreflexotherapy.
1998
Our investigations have confirmed that the osteoreceptive sensory system participates in the polysensoric regulation of animal and human posture. Experiments with animals have demonstrated that the irritation of osteoreceptors by electric pulses leads to osteoreceptive response potentials of the same parts of the brain (Deiter's nuclei, cerebellum, caudate nucleus, cortical motor centre etc.) which participate in the regulation of animal and human posture and other motion acts. Close functional relations have been established between the skin, bone, vestibular and muscle sensory systems in the brain structures where the osteoreceptive excitation converges. The studies of osteoreceptive sens…
Music in the moment? Revisiting the effect of large scale structures.
2007
The psychological relevance of large-scale musical structures has been a matter of debate in the music community. This issue was investigated with a method that allows assessing listeners' detection of musical incoherencies in normal and scrambled versions of popular and contemporary music pieces. Musical excerpts were segmented into 28 or 29 chunks. In the scrambled version, the temporal order of these chunks was altered with the constraint that the transitions between two chunks never created local acoustical and musical disruptions. Participants were required (1) to detect on-line incoherent linking of chunks, (2) to rate aesthetic quality of pieces, and (3) to evaluate their overall co…
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Spectators' Identification with French Sports Teams: A French Adaptation of the Sport Spectator Identification Scale
2007
International audience; Due to the works of Wann and colleagues, spectators' identification with teams has taken on a central role in the study of sports spectators' thought and behavior. However, no research in this area has measured identification with sports teams in the French context. Two studies attempted to develop a valid and reliable French version of the Sport Spectator Identification Scale (SSIS) developed by Wann and Branscombe in 1993 to measure team identification. In Study 1, 200 physical education students completed a French translation of the SSIS and several questions concerning their involvement, investment, and evaluation of the team's future performance. Results showed …
Self-Perceptions of Sicilian Male Youth
1972
An Italian version of the AVA was included in the test battery for a pilot study of Project Talent in Sicily. Ss were 395 male students attending a public technical school in Palermo, Sicily. Profiles of basic self and social self-concepts, as well as the composite self-concept yielded by the AVA, were analyzed for the Sicilian sample. The latter were also compared with those for an American normative sample ( N = 7732). Two heavily concentrated clusters were noted in the self-perceptions of the Sicilians in contrast to those of the American sample which are more evenly distributed throughout the personality spheroid comprising the AVA model.
Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration
2011
Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…
Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.
2014
Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …
Influence of the luminance level on visual performance with a disposable soft cosmetic tinted contact lens.
2001
The purpose of the present work was to study the effect on visual performance of wearing disposable soft tinted contact lenses for cosmetic purposes. Parameters such as contrast sensitivity (Vistech 6000), colour vision (Farnsworth-Munsell 100-Hue colour test), visual fields (static Goldmann perimetry) and subjective vision (what the wearer feels while wearing the lenses) were studied under different illumination levels in order to check for possible vision losses while wearing these contact lenses at low illumination levels. Sixteen emmetropic subjects were fitted consecutively with seven pairs of different colour lenses (Optima Colors lenses by BauschLomb), and the experimental parameters…