Search results for "shear"
showing 10 items of 804 documents
Euclid preparation. XII. Optimizing the photometric sample of the Euclid survey for galaxy clustering and galaxy-galaxy lensing analyses
2021
Pocino, A., et al. (Euclid Collaboration)
Free vibrations of magnetoelectric bimorph beam devices by third order shear deformation theory
2010
Role of Hemodynamic Forces in Unruptured Intracranial Aneurysms: An Overview of a Complex Scenario.
2017
Background An understanding of the natural history of unruptured intracranial aneurysms (IAs) has always played a critical role in presurgical or endovascular planning, to avoid possibly fatal events. Size, shape, morphology, and location are known risk factors for rupture of an aneurysm, but morphologic parameters alone may not be sufficient to perform proper rupture risk stratification. Methods We performed a systematic PubMed search and focused on hemodynamics forces that may influence aneurysmal initiation, growth, and rupture. Results We included 223 studies describing several hemodynamic parameters related to aneurysm natural history. In these studies, different modalities of aneurysm…
Computational fluid dynamics simulation to evaluate aortic coarctation gradient with contrast-enhanced CT
2014
Coarctation of aorta (CoA) is a narrowing of the aorta leading to a pressure gradient (Delta P) across the coarctation, increased afterload and reduced peripheral perfusion pressures. Indication to invasive treatment is based on values of maximal (systolic) trans-coarctation Delta P. A computational fluid dynamic (CFD) approach is herein presented for the non-invasive haemodynamic assessment of Delta P across CoA. Patient-specific CFD simulations were created from contrast-enhanced computed tomography (CT) and appropriate flow boundary conditions. Computed Delta P was validated with invasive intravascular trans-CoA pressure measurements. Haemodynamic indices, including pressure loss coeffic…
Healon5 viscoadaptive formulation: Comparison to Healon and Healon GV
2001
Abstract Purpose To compare the rheological characteristics of a viscoadaptive viscoelastic formulation with those of 2 standard ophthalmic viscosurgical devices (OVDs). Setting Department of Ophthalmology, Johannes Gutenberg-University, and Max Planck-Institute for Polymer Research, Mainz, Germany. Methods An independent comparative study of 3 OVDs of sodium hyaluronate (Healon®, Healon GV®, and Healon®5) was performed using the Advanced Rheometric Expansion System to analyze rheologic behavior (eg, dynamic frequency dependence of the complex viscosity) as well as rheological parameters (eg, viscosity at zero shear rate, pseudoplasticity, relaxation time, elastic and viscous modulus). Resu…
Advancing frontiers in rheumatic and musculoskeletal imaging.
2021
AbstractIn recent years, technological improvements allowed imaging modalities to become increasingly essential in achieving early and precise diagnoses in the field of rheumatic and musculoskeletal diseases (RMDs). To date, imaging examinations are routinely used in all steps of diagnostic and therapeutic care pathways of patients affected by RMDs. The articles published in this Article Collection clearly show the efforts of researchers to find innovative applications of musculoskeletal imaging in clinical practice and to face the crucial challenges that remain in the interpretation and quality control of images. Highly performing diagnostic technologies are currently available to early di…
Comparisons of processing and strength properties of two adhesive systems for composite joints
2007
Abstract In the present study rheological, static and impact tests are carried out on two adhesive resins usually employed in marine applications; then single lap joint tests are conducted on composites joints evidencing the effect of the curing time of both resins on the mechanical properties of the joint. The applicability and workability conditions of the adhesive resins are determined evaluating the curing evolution by a preliminary rheological analysis; then the relation of curing properties with the mechanical performances of the resins themselves and with ones of the composite joints is estimated. Static flexural and Izod impact tests are performed on the resins at increasing time af…
Analysis and optimization of hybrid double lap aluminum-GFRP joints
2014
In this paper a systematic investigation of the mechanical performance of hybrid double-lap Al-GFRP bonded-bolted joints, has been carried out by using experimental analyses and numerical simulations. In order to detect the optimal geometric configuration, as well as to highlight the contribution of adhesive and bolts, the results relative to hybrid joints have been compared with those of simply adhesively bonded and simply bolted joints. The experimental and numerical results have shown that by using the minimum overlap length provided from theory, the bolt leads to a significant decreasing of both the maximum shear and the maximum peel stresses in the adhesive layer and, consequently, the…
Redesign of a Reverse Shoulder Prosthesis: Kinematic and Mechanical Study
2014
In this work a commercial reverse shoulder prosthesis has been redesigned to improve performances in terms of range of movements of the implant and stability to dislocation. A kinematic and mechanic study has been performed using a realistic solid model of the prothesised shoulder: in particular, all the components of the prosthesis have been acquired via a 3D laser scanner and inserted in a virtual humerus-glenoid system by reproducing the common surgical procedure. The final model has been used to measure the maximum angles of abduction and rotation of the arm and the shear forces that cause dislocation. Modifications proposed to the commercial prosthesis are: a different orientation of t…
Effects of muscle activation on shear between human soleus and gastrocnemius muscles
2015
Lateral connections between muscles provide pathways for myofascial force transmission. To elucidate whether these pathways have functional roles in vivo, we examined whether activation could alter the shear between the soleus (SOL) and lateral gastrocnemius (LG) muscles. We hypothesized that selective activation of LG would decrease the stretch-induced shear between LG and SOL. Eleven volunteers underwent a series of knee joint manipulations where plantar flexion force, LG, and SOL muscle fascicle lengths and relative displacement of aponeuroses between the muscles were obtained. Data during a passive full range of motion were recorded, followed by 20° knee extension stretches in both pass…