Search results for "silicon"

showing 10 items of 1391 documents

The SAGE spectrometer: A tool for combined in-beam gamma-ray and conversion electron spectroscopy

2010

International audience; The sage spectrometer allows simultaneous in-beam -ray and internal conversion electron measurements, by combining a germanium detector array with a highly segmented silicon detector and an electron transport system. sage is coupled with the ritu gas- lled recoil separator and the great focal-plane spectrometer for recoil-decay tagging studies. Digital electronics are used both for the ray and the electron parts of the spectrometer. sage was commissioned in the Accelerator Laboratory of the University of Jyvaskyla in the beginning of 2010.

PhysicsHistorySpectrometer010308 nuclear & particles physicsbusiness.industryPhysics::Instrumentation and DetectorsElectron[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]7. Clean energy01 natural sciencesElectron spectroscopyRecoil separatorComputer Science ApplicationsEducationSemiconductor detectorNuclear physicsOpticsInternal conversion0103 physical sciencesSilicon detectorHigh Energy Physics::Experiment010306 general physicsbusinessNuclear ExperimentBeam (structure)
researchProduct

Precise determination of the 1s Lamb shift in hydrogen-like lead and gold using microcalorimeters

2016

Quantum electrodynamics in very strong Coulomb fields is one scope which has not yet been tested experimentally with suffcient accuracy to really determine whether the perturbative approach is valid. One sensitive test is the determination of the 1s Lamb Shift in highly-charged very heavy ions. The 1s Lamb Shift of hydrogen-like lead (Pb81+) and gold (Au78+) has been determined using the novel detector concept of silicon microcalorimeters for the detection of hard X-rays. The results of (260 +- 22) eV for lead and (208 +- 13) eV for gold are within error bars in good agreement with theoretical predictions. For hydrogen-like lead, this represents the most accurate determination of the 1s Lam…

PhysicsHydrogenSiliconAtomic Physics (physics.atom-ph)010308 nuclear & particles physicsDetectorFOS: Physical scienceschemistry.chemical_elementCondensed Matter Physics01 natural sciencesAtomic and Molecular Physics and OpticsPhysics - Atomic PhysicsIonLamb shiftchemistry0103 physical sciencesCoulombElectric potentialAtomic physics010306 general physicsSpectroscopyJournal of Physics B: Atomic, Molecular and Optical Physics
researchProduct

Spectroscopic Tools Applied to Element Z = 115 Decay Chains

2014

Nuclides that are considered to be isotopes of element Z = 115 were produced in the reaction 48Ca + 243Am at the GSI Helmholtzzentrum für Schwerionenforschung Darmstadt. The detector setup TASISpec was used. It was mounted behind the gas-filled separator TASCA. Thirty correlated α-decay chains were found, and the energies of the particles were determined with high precision. Two important spectroscopic aspects of the offline data analysis are discussed in detail: the handling of digitized preamplified signals from the silicon strip detectors, and the energy reconstruction of particles escaping to upstream detectors relying on pixel-by-pixel dead-layer thicknesses.

PhysicsIsotopeSiliconPhysics::Instrumentation and DetectorsPhysicsQC1-999DetectorSeparator (oil production)Mechanical engineeringchemistry.chemical_element7. Clean energyNuclear physicschemistryPhysical SciencesSubatomic Physicsddc:530Decay chainNuclideNuclear ExperimentLine (formation)EPJ Web of Conferences
researchProduct

Direct determination of the mass of28Si as a contribution to a new definition of the kilogram

1993

The mass of 28Si has been determined to be m(28Si) = 27.976 926 57(30) u by comparing the cyclotron frequencies of the singly charged ions 12C+, 12C+3 and 28Si+ in a Penning trap mass spectrometer. The experimental technique and the setup are described. The obtained accuracy as well as possible improvements are discussed. Our measurements are related to current efforts to base the kilogram on atomic properties by using an almost perfect single crystal of silicon.

PhysicsKilogramCyclotronCondensed Matter PhysicsPenning trapMass spectrometryAtomic and Molecular Physics and OpticsAtomic massIonlaw.inventionlawIsotopes of siliconAtomic physicsSingle crystalMathematical PhysicsPhysica Scripta
researchProduct

Construction, Commissioning and First Results of a Highly Granular Hadron Calorimeter with SiPM-on-Tile Read-out

2018

The CALICE collaboration is developing a highly granular Analogue Hadron sampling CALorimeter (AHCAL) for a future electron-positron collider. Very small detection units are required for the AHCAL due to an optimized design for the Particle Flow Algorithm. This is realized with scintillator tiles each wrapped in reflector foil and individually read out by a silicon photomultiplier (SiPM). These scintillator tiles and SiPMs are assembled on readout boards (HCAL Base Unit, HBU) which are integrated later on in the AHCAL detector stack. With this design a higher energy resolution is achievable, but also a large quantity of components (around 8,000,000 scintillator tiles and SiPMs) are needed t…

PhysicsLarge Hadron ColliderCalorimeter (particle physics)Physics::Instrumentation and Detectors010308 nuclear & particles physicsNuclear engineeringDetectorLinearityScintillator01 natural sciences030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineSilicon photomultiplierStack (abstract data type)law0103 physical sciencesDetectors and Experimental TechniquesInfrastructure for advanced calorimeters [14]Collider2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC)
researchProduct

Production ofD, D * andD s mesons in 200 GeV/c ?? K ? andp-Si interactions

1988

The NA 32 experiment at the CERN SPS has collected 38 million hadronic interactions with incident 200 GeV/c π−,K− andp beam. Using a segmented silicon active target and a telescope of high resolution silicon microstrip counters we have selected fully reconstructedD0→K−π+,D0→K−π+π+π−,D+→K−π+π+,Ds+→K−K+π+π+ and charge conjugate decays. The integrated cross-sections forDo,D+D*+ andDs+ meson production and the dependence of the cross-section on longitudinal and transverse momentum of theD are presented.

PhysicsLarge Hadron ColliderPhysics and Astronomy (miscellaneous)SiliconMesonHadronchemistry.chemical_elementCharge (physics)Elementary particleNuclear physicschemistryEngineering (miscellaneous)Particle Physics - ExperimentBeam (structure)ConjugateZeitschrift f�r Physik C Particles and Fields
researchProduct

ATLAS SemiConductor Tracker: operation and performance

2011

The SemiConductor Tracker (SCT) is a silicon strip detector and one of the key precision tracking devices in the Inner Detector of the ATLAS (A Toroidal LHC ApparatuS) experiment at CERN. The SCT installation in the ATLAS experimental cavern was completed in 2007 and it has been operational since then. An extensive commissioning phase followed, during which calibration data was collected and the performance of the system was studied. The SCT was ready for the first LHC proton-proton collisions and it continues recording data successfully since then. In this paper, the current status, operation and performance of the SCT is reviewed, including results from data-taking periods in 2010 and 201…

PhysicsLarge Hadron Colliderbusiness.industryPhysics::Instrumentation and DetectorsDetectorTracking (particle physics)Nuclear physicsmedicine.anatomical_structureSemiconductorAtlas (anatomy)medicineCalibrationAstrophysics::Solar and Stellar AstrophysicsDetectors and Experimental TechniquesbusinessSilicon radiation detectorsComputer hardware
researchProduct

Time Of Flight measurements via two LiDAR systems with SiPM and APD

2016

In this paper, we present an experimental comparison of two LiDAR systems, employing the SiPM and the APD as photodetectors, in terms of TOF measurements differing for the distance of the target and at different intensities of ambient light. The use of the APD represents the conventional approach, while the implementation of the SiPM is innovative. The performed measurements achieved very promising results, thus demonstrating the effectiveness of our LiDAR based on SiPM.

PhysicsLiDAR010308 nuclear & particles physicsbusiness.industrySiPM020208 electrical & electronic engineeringTOFPhotodetectorAPD02 engineering and technologyTime of Flight01 natural sciencesSettore ING-INF/01 - ElettronicaSilicon PhotoMultiplierTime of flightSilicon photomultiplierLidarOptics0103 physical sciences0202 electrical engineering electronic engineering information engineeringOptoelectronicsphotodetectorbusiness
researchProduct

Efficient on-axis SLM engineering of optical vector modes

2020

Abstract This work presents a method for the efficient experimental generation of arbitrary polarized vector beam modes. The optical system employs two liquid-crystal on silicon (LCOS) spatial light modulators (SLM) in a common path architecture, avoiding the use of beam-splitters. Each SLM displays a different phase-only mask, each one encoding a different pattern onto two orthogonal linear polarization components of the input beam. These phase-only masks are designed using a recently proposed random technique to encode complex amplitude values. This encoding technique reconstructs the complex function on-axis, thus avoiding incorporating carrier phases. By addressing such properly designe…

PhysicsLinear polarizationbusiness.industryMechanical EngineeringHolography02 engineering and technology021001 nanoscience & nanotechnologyPolarization (waves)ENCODE01 natural sciencesAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materialslaw.invention010309 opticsLiquid crystal on siliconSuperposition principleCommon pathOpticslaw0103 physical sciencesElectrical and Electronic Engineering0210 nano-technologybusinessComplex amplitudeOptics and Lasers in Engineering
researchProduct

Vector modes generation using efficient on-axis system

2020

Arbitrary polarized vector beam modes are efficiently generated. We use two flicker-free liquid-crystal on silicon (LCOS) spatial light modulators (SLM) in an on-axis common path architecture. Different superpositions of vector modes are obtained with high light efficiency.

PhysicsLiquid crystal on siliconAxis systemCommon pathOpticsSiliconchemistrybusiness.industryLight beamchemistry.chemical_elementbusinessBeam (structure)Circular polarizationOSA Advanced Photonics Congress (AP) 2020 (IPR, NP, NOMA, Networks, PVLED, PSC, SPPCom, SOF)
researchProduct