Search results for "sonography"
showing 10 items of 978 documents
Pathogenesis and prophylaxis of circulatory reactions during total hip replacement
1993
Circulatory reactions such as a drop in blood pressure, bradycardia, cardiac arrest, and even intraoperative death after insertion of the stem are well known events during total hip replacement. The present paper reports bone marrow intravasation after rise of intramedullary pressure in the femoral cavity during insertion of hip prostheses, demonstrated by intraoperative transesophageal echocardiography. In an animal study, the ultrasound echoes were identified as "mixed emboli" consisting of a core of bone marrow surrounded by thrombus. These results suggested the use of an intramedullary plug to restrict the intravasation of bone marrow. A trial was undertaken in 60 total hip replacement …
AT1-receptor blockade with irbesartan improves peripheral but not coronary endothelial dysfunction in patients with stable coronary artery disease
2007
Activation of the renin-angiotensin-aldosterone system plays an important role in the pathogenesis of endothelial dysfunction and atherosclerosis. Studies evaluating the effect of AT1-receptor blockers on endothelial dysfunction in patients with coronary artery disease (CAD) revealed mixed results. Studies addressing the effects of AT1-receptor blockers on the coronary and peripheral function in the same study population, are still lacking. We therefore aimed to test the effects of long-term therapy with the AT1-receptor blocker irbesartan (IRB) on both, the coronary and peripheral endothelial function in patients with CAD. Seventy-two patients with CAD were randomly assigned to double-blin…
Common Genetic Variation in Relation to Brachial Vascular Dimensions and Flow-Mediated Vasodilation
2019
Common Genetic Variation in Relation to Brachial Vascular Dimensions and Flow-Mediated Vasodilation
3D versus 2D contrast-enhanced sonography in the evaluation of therapeutic response of hepatocellular carcinoma after locoregional therapies: prelimi…
2014
Objective: To investigate diagnostic performance of 3D contrast-enhanced ultrasound (CEUS) compared with 2D CEUS in the assessment of therapeutic response of hepatocellular carcinoma (HCC) treated with locoregional therapies (LRT). Materials and methods: Twenty-three consecutive patients (13 men and 10 women; mean age 65.5 years) with 23 HCCs (size range 1.2–7.2 cm; mean size 2.9 ± 1.4 cm) treated by means of radiofrequency ablation (RFA n = 9), transarterial chemoembolization (TACE n = 8), combined RFA and TACE (n = 3), percutaneous alcoholization (n = 2), and wedge resection (n = 1) underwent 2D and 3D CEUS 1 month (30 ± 2 days) after treatment. Magnetic resonance (n = 17) and computed to…
Hepatocellular cancer response to radiofrequency tumor ablation: contrast-enhanced ultrasound
2007
Radiofrequency ablation (RFA) is increasingly being used as percutaneous treatment of choice for patients with early stage hepatocellular carcinoma (HCC). An accurate assessment of the RFA therapeutic response is of crucial importance, considering that a complete tumor ablation significantly increases patient survival, whereas residual unablated tumor calls for additional treatment. Imaging modalities play a pivotal role in accomplishing this task, but ultrasound (US) is not considered a reliable modality for the evaluation of the real extent of necrosis, even when color/power Doppler techniques are used. Recently, newer microbubble-based US contrast agents used in combination with grey-sca…
Midterm follow-up after DC-BEAD™-TACE of Hepatocellular Carcinoma (HCC)
2012
Abstract Aim To determine local response, its predictors and survival and complication rates after DC-Bead™-TACE in patients with hepatocellular carcinoma (HCC). Materials and methods DC-Beads™ are non-resorbable, polyvinyl-alcoholic hydrophilic microspheres. They release high amounts of chemotherapeutics directly into the tumour. Delivery is sustained over time, tumour feeders are embolised. We used beads from 100–300 to 500–700 μm loaded with Doxorubicin (max. 150 mg/4 ml). Fifty patients (mean age: 68.5 ± 8.8 years) with HCC were analysed. DC-Bead™-TACE was performed once or repeated in two-month intervals. Imaging scans (CT or MRI) were done one-month following each procedure. To evalua…
Extracranial internal carotid artery occlusion: the role of common carotid artery volume flow.
2002
BACKGROUND AND PURPOSE Quantitative measurement of blood flow volume in the common carotid artery (CCA) is now possible using the color velocity imaging quantification (CVI-Q) ultrasound technique. The aim of this study was to evaluate the cerebral hemodynamic effects of unilateral internal carotid artery (ICA) occlusion on CCA blood flow volumes (FVs) using CVI-Q. METHODS Records of ultrasound studies in our neurosonology laboratory were retrospectively reviewed to identify patients with unilateral ICA occlusions who at a minimum received both a routine color duplex carotid ultrasound examination and quantitative measurement of FV in the CCA, bilaterally, using the CVI-Q method. A total of…
Optic Nerve Decompression Improves Hemodynamic Parameters in Papilledema
1993
Purpose: The purpose of this study is to examine changes in color Doppler imaging parameters before and after optic nerve sheath decompression (ONSD) for chronic papilledema caused by pseudotumor cerebri (PTC). Methods: Color Doppler imaging was performed within 48 hours before surgery and within 48 hours after the procedure using a color Doppler unit with a 7.5-MHz phased linear transducer. Pulsed Doppler spectrum analyses were recorded digitally on videotape from the ophthalmic, central retinal, and short posterior ciliary arteries, using a 0.4 × 0.6-mm sample volume. Results: Blood flow velocities in the ophthalmic, short posterior ciliary, and central retinal arteries of 24 eyes were si…
Color Doppler Imaging of Arterial Blood Flow in Central Retinal Vein Occlusion
1994
Purpose: The hemodynamics of the retrobulbar arterial circulation of patients with central retinal vein occlusion were evaluated in order to better understand the pathophysiology of this disease. Methods: Color Doppler imaging was used to measure the peak systolic velocity and vascular resistance (pulsatility index) in the retrobulbar arteries of involved eyes and clinically healthy fellow eyes of patients with central retinal vein occlusion and in the control eyes of age- and sex-matched healthy volunteers. Results: Average peak systolic velocity was significantly lower and average vascular resistance was significantly higher in the central retinal artery of involved eyes of patients with …
Prognostic Heterogeneity of Endosonographic T3 Rectal Cancer
2009
PURPOSE: This study aimed to assess the prognostic implications of uT3 rectal carcinomas according to the tumor thickness and to analyze the correlation between this ultrasound-based parameter and other prognostic factors. METHODS: Seventy-four patients with uT3(pM0) rectal tumors underwent primary surgery from 1996 to 2003. Preoperative endorectal ultrasound was used to assess uN stage, maximum tumor perimeter, and maximum tumor thickness. An ultrasound maximum tumor thickness cutoff point for local recurrence subdividing T3 tumors into uT3a and uT3b was established. RESULTS: Median follow-up was 41 months (range, 24-59). The 5-year actuarial local and overall recurrence rates were 9.82 pe…