Search results for "sonography"

showing 10 items of 978 documents

Medical Student Ultrasound Education, a WFUMB Position Paper, Part I, response to the letter to the Editor.

2019

medicine.medical_specialtyLetter to the editorStudents MedicalAcoustics and UltrasonicsRadiological and Ultrasound Technologybusiness.industryUltrasoundBiophysicsmedicinePosition paperHumansRadiology Nuclear Medicine and imagingMedical physics610 Medicine & healthPsychologybusiness360 Social problems & social servicesUltrasonographyUltrasound in medicinebiology
researchProduct

Contrast-enhanced ultrasound of hepatocellular carcinoma: where do we stand?

2019

Contrast-enhanced ultrasound (CEUS) represents a significant breakthrough in ultrasonography (US), and it is being increasingly used for the evaluation of focal liver lesions (FLLs). CEUS is unique in that it allows non-invasively assessment of liver perfusion in real time throughout the vascular phase, which has led to dramatic improvements in the diagnostic accuracy of US in the detection and characterization of FLLs, the choice of therapeutic procedures, and the evaluation of response. Currently, CEUS is included as a part of the suggested diagnostic work-up of FLLs, including in cirrhotic patients with hepatocellular carcinoma, resulting in better patient management and cost-effective d…

medicine.medical_specialtyLiver perfusionlcsh:Medical technologyHepatocellular carcinomaDiagnostic accuracyReview Article030218 nuclear medicine & medical imagingUltrasound contrast mediaLiver cirrhosi03 medical and health sciences0302 clinical medicinemedicineContrast-enhanced ultrasonographyRadiology Nuclear Medicine and imagingUltrasound contrast mediaUltrasonographybusiness.industryUltrasoundmedicine.diseasePatient managementlcsh:R855-855.5LiverHepatocellular carcinomaLiver cirrhosis030211 gastroenterology & hepatologyRadiologyUltrasonographybusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaContrast-enhanced ultrasoundUltrasonography
researchProduct

Endorektale Sonographie zur präoperativen Beurteilung der Infiltrationstiefe von Rektumtumoren

1990

From June 1987 to February 1990, 142 out of 319 patients with rectal tumours were investigated by ultrasound scanning with the object of ascertaining the depth to which the tumour had infiltrated. This examination proved completely feasible in 130 of these patients (84 men, 46 women, mean age 61.7 [42-84] years). Postoperative histological examination revealed an adenoma (n = 59) or a T1 carcinoma (n = 19), while intrarectal ultrasonography disclosed the same findings in 79 patients (true-positive in 75 cases). A T2-tumour was diagnosed by histological examination in 24 patients, and by ultrasonography in 22 (true-positive in 18 cases). The histological diagnosis of a tumour in stage T3 or …

medicine.medical_specialtyLocal excisionAdenomabusiness.industryUltrasoundGeneral MedicineRectal Tumorsmedicine.diseaseCarcinomaMedicineRadiologyStage (cooking)UltrasonographybusinessInfiltration (medical)DMW - Deutsche Medizinische Wochenschrift
researchProduct

Endobronchial ultrasound in the diagnosis of lung cancer.

2010

medicine.medical_specialtyLung Neoplasmsbusiness.industryGeneral Medicinemedicine.diseaseText miningBronchoscopymedicineHumansRadiologyEndobronchial ultrasoundbusinessLung cancerUltrasonography InterventionalArchivos de bronconeumologia
researchProduct

Assessment of etanercept efficacy in the treatment of psoriatic arthritis: ultrasonography of Achilles tendon

2015

medicine.medical_specialtyMEDLINEArthritisDermatologyAchilles TendonEtanerceptEtanercept030207 dermatology & venereal diseases03 medical and health sciencesPsoriatic arthritis0302 clinical medicinemedicineHumansUltrasonography030203 arthritis & rheumatologyAchilles tendonbusiness.industryArthritis Psoriaticmedicine.diseaseDermatologymedicine.anatomical_structureInfectious DiseasesUltrasonographybusinessmedicine.drugHuman2708
researchProduct

Accuracy of ultrasonography in the diagnosis of acute calculous cholecystitis: review of the literature.

2013

Background To evaluate the accuracy of ultrasonography in the diagnosis of acute calculous cholecystitis in comparison with other imaging modalities. Methods The authors performed a search of the Medline/ PubMed (National Library of Medicine, Bethesda, Maryland) for original research and review publications examining the accuracy of ultrasonography in the diagnosis of acute calculous cholecystitis. The search design utilized a single or combination of the following terms : (1) acute cholecystitis, (2) ultrasonography, (3) computed tomography, (4) magnetic resonance cholangiopancreatography and (5) cholescintigraphy. This review was restricted to human studies and to English-language literat…

medicine.medical_specialtyMEDLINEComputed tomographyAcute calculous cholecystitis UltrasonographyCholescintigraphyAcute calculous cholecystitischolangiopancreatographyAcute calculous cholecystitis ultrasonography; Cholescintigraphy; Computed tomography; Magnetic resonance cholangiopancreatographyComputed Tomographycholecystitismedicineultrasound; Computed tomography; cholangiopancreatography; cholecystitisIn patientUltrasonographyMagnetic resonance cholangiopancreatographymedicine.diagnostic_testRadiological and Ultrasound Technologybusiness.industryultrasoundAcute calculous cholecystitis Ultrasonography; Computed Tomography; Magnetic Resonance CholangiopancreatographyResearchInterventional radiologymedicine.diseaseCholescintigraphyCholecystitisRadiologyUltrasonographyMagnetic Resonance Cholangiopancreatographybusiness
researchProduct

Undetected Malignancies of the Breast: Dynamic Contrast-enhanced MR Imaging at 1.0 T

2002

To assess the prevalence and characteristics of malignant breast lesions not identified with magnetic resonance (MR) imaging.Breast tissue specimens were obtained in 464 of 967 patients who had undergone dynamic gadolinium-enhanced T1-weighted fast low-angle shot three-dimensional MR imaging of both breasts. A comparison of sensitivity, specificity, and predictive values of the prospectively recorded findings of mammography, ultrasonography (US), and MR imaging with the histopathologic results was performed with receiver operating characteristic (ROC) curve analysis. MR imaging examination findings that caused a false-negative diagnosis were reviewed to identify possible sources of error.Hi…

medicine.medical_specialtyMammary glandBreast NeoplasmsGadoliniumSensitivity and SpecificityPredictive Value of TestsmedicineHumansMammographyRadiology Nuclear Medicine and imagingmedicine.diagnostic_testReceiver operating characteristicbusiness.industryCurve analysisMagnetic resonance imagingImage EnhancementMagnetic Resonance ImagingMr imagingDynamic contrastmedicine.anatomical_structureROC CurveFemaleHistopathologyUltrasonography MammaryRadiologyArtifactsNuclear medicinebusinessRadiology
researchProduct

Non‐invasive diagnostic techniques in pigmentary skin disorders and skin cancer

2021

Background Diagnosis of pigmentary skin disorders, pre-cancerous and cancerous skin diseases is traditionally relied on visual assessment. The most widely applied invasive diagnostic technique is the skin biopsy. There have been significant technological advances in non-invasive diagnostic methods for skin disorders. Objective The objective of this article is to discuss different non-invasive diagnostic modalities, used in the diagnosis of pigmentary skin disorders and cutaneous cancers. Methods Comprehensive literature search was performed to screen articles related to non-invasive diagnostic techniques in pigmentary skin disorders and cutaneous cancers. Articles published in journals inde…

medicine.medical_specialtyMicroscopy ConfocalSkin Neoplasmsmedicine.diagnostic_testbusiness.industryNon invasiveMagnetic resonance imagingDermatologymedicine.diseaseSensitivity and SpecificityDermatologyDiagnostic modalitiesClinical trialOptical coherence tomographyBiopsySkin biopsymedicineHumansSkin cancerbusinessSkinUltrasonographyJournal of Cosmetic Dermatology
researchProduct

Which is the best ultrasound parameter for the prediction of adverse perinatal outcome within 1 day of delivery?

2021

To compare the accuracies of several sonographic parameters for the prediction of adverse perinatal outcome (APO) prior to delivery.This was a prospective study of fetuses attending the day hospital unit of a tertiary referral hospital that were scanned at 34-41 weeks and gave birth within 24 h of examination. APO was defined as a composite of abnormal intrapartum fetal heart rate or intrapartum fetal scalp pH7.20 requiring urgent cesarean section, neonatal umbilical cord pH7.10, 5' Apgar score7 and postpartum admission to neonatal or pediatric intensive care units. The accuracies of the middle cerebral, vertebral and umbilical arteries pulsatility index multiples of the median (MoM), the c…

medicine.medical_specialtyMiddle Cerebral ArteryPerinatal outcomemacromolecular substancesUltrasonography PrenatalUmbilical ArteriesPregnancyPredictive Value of Testsmedicine.arterymedicineHumansProspective StudiesProspective cohort studyChildFetusbusiness.industryObstetricsCesarean SectionUltrasoundInfant NewbornPregnancy OutcomeObstetrics and GynecologyFetal dopplerUltrasonography DopplerPulsatile FlowPediatrics Perinatology and Child HealthMiddle cerebral arteryFemalebusinessThe journal of maternal-fetalneonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians
researchProduct

Birth-weight differences at term are explained by placental dysfunction and not by maternal ethnicity. Study in newborns of first generation immigran…

2020

The aim of the study was to investigate the influence of ethnicity and cerebroplacental ratio (CPR) on the birth weight (BW) of first generation Indo-Pakistan immigrants' newborns.This was a retrospective study in a mixed population of 620 term Caucasian and Indo-Pakistan pregnancies, evaluated in two reference hospitals of Spain and Italy. All fetuses underwent a scan and Doppler examination within two weeks of delivery. The influence of fetal gender, ethnicity, GA at delivery, CPR, maternal age, height, weight and parity on BW was evaluated by multivariable regression analysis.Newborns of first generation Indo-Pakistan immigrants were smaller than local Caucasian newborns (mean BW mean= 3…

medicine.medical_specialtyMiddle Cerebral Arterymedia_common.quotation_subjectBirth weightPlacentaImmigrationEthnic groupEmigrants and ImmigrantsGestational AgeUltrasonography PrenatalUmbilical ArteriesPlacental dysfunctionPregnancymedicineEthnicityBirth WeightHumanshealth care economics and organizationsmedia_commonRetrospective StudiesObstetricsbusiness.industryInfant NewbornParturitionObstetrics and GynecologyFetal dopplerFirst generationTerm (time)Pediatrics Perinatology and Child Healthpopulation characteristicsFemaleFetal nutritionbusinessgeographic locationsThe journal of maternal-fetalneonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians
researchProduct