Search results for "spectra"
showing 10 items of 3542 documents
Hyperspectral dimensionality reduction for biophysical variable statistical retrieval
2017
Abstract Current and upcoming airborne and spaceborne imaging spectrometers lead to vast hyperspectral data streams. This scenario calls for automated and optimized spectral dimensionality reduction techniques to enable fast and efficient hyperspectral data processing, such as inferring vegetation properties. In preparation of next generation biophysical variable retrieval methods applicable to hyperspectral data, we present the evaluation of 11 dimensionality reduction (DR) methods in combination with advanced machine learning regression algorithms (MLRAs) for statistical variable retrieval. Two unique hyperspectral datasets were analyzed on the predictive power of DR + MLRA methods to ret…
Empirical and physical estimation of Canopy Water Content from CHRIS/PROBA data
2013
20 páginas, 4 tablas, 7 figuras.
Evaluation of the MODIS Albedo product over a heterogeneous agricultural area
2013
In this article, the Moderate Resolution Imaging Spectroradiometer MODIS Bidirectional Reflectance Distribution Function BRDF/Albedo product MCD43 is evaluated over a heterogeneous agricultural area in the framework of the Earth Observation: Optical Data Calibration and Information Extraction EODIX project campaign, which was developed in Barrax Spain in June 2011. In this method, two models, the RossThick-LiSparse-Reciprocal RTLSR which corresponds to the MODIS BRDF algorithm and the RossThick-Maignan-LiSparse-Reciprocal RTLSR-HS, were tested over airborne data by processing high-resolution images acquired with the Airborne Hyperspectral Scanner AHS sensor. During the campaign, airborne im…
Inflight Radiometric Calibration of New Horizons' Multispectral Visible Imaging Camera (MVIC)
2017
© 2016 Elsevier Inc. We discuss two semi-independent calibration techniques used to determine the inflight radiometric calibration for the New Horizons’ Multi-spectral Visible Imaging Camera (MVIC). The first calibration technique compares the measured number of counts (DN) observed from a number of well calibrated stars to those predicted using the component-level calibration. The ratio of these values provides a multiplicative factor that allows a conversation between the preflight calibration to the more accurate inflight one, for each detector. The second calibration technique is a channel-wise relative radiometric calibration for MVIC's blue, near-infrared and methane color channels us…
2019
The HyPlant imaging spectrometer is a high-performance airborne instrument consisting of two sensor modules. The DUAL module records hyperspectral data in the spectral range from 400–2500 nm, which is useful to derive biochemical and structural plant properties. In parallel, the FLUO module acquires data in the red and near infrared range (670–780 nm), with a distinctly higher spectral sampling interval and finer spectral resolution. The technical specifications of HyPlant FLUO allow for the retrieval of sun-induced chlorophyll fluorescence (SIF), a small signal emitted by plants, which is directly linked to their photosynthetic efficiency. The combined use of both HyPlant modules opens up …
The high overtone and combination levels of SF6 revisited at Doppler-limited resolution: A global effective rovibrational model for highly excited vi…
2017
Abstract Sulfur hexafluoride is an important prototypal molecule for modeling highly excited vibrational energy flow and multi quanta absorption processes in hexafluoride molecules of technological importance. It is also a strong greenhouse gas of anthropogenic origin. This heavy species, however, features many hot bands at room temperature (at which only 30% of the molecules lie in the ground vibrational state), especially those originating from the lowest, v 6 =1 vibrational state. Using a cryogenic long path cell with variable optical path length and temperatures regulated between 120 and 163 K, coupled to Synchrotron Radiation and a high resolution interferometer, Doppler-limited spectr…
The GAPS Programme with HARPS-N at TNG: . Atmospheric Rossiter-McLaughlin effect and improved parameters of KELT-9b
2019
In the framework of the GAPS project, we observed the planet-hosting star KELT-9 (A-type star, VsinI$\sim$110 km/s) with the HARPS-N spectrograph at the TNG. In this work we analyse the spectra and the extracted radial velocities (RVs), to constrain the physical parameters of the system and to detect the planetary atmosphere of KELT-9b. We extracted from the high-resolution optical spectra the mean stellar line profiles with an analysis based on the Least Square Deconvolution technique. Then, we computed the stellar RVs with a method optimized for fast rotators, by fitting the mean stellar line profile with a purely rotational profile instead of using a Gaussian function. The new spectra an…
Eco-Friendly Estimation of Heavy Metal Contents in Grapevine Foliage Using In-Field Hyperspectral Data and Multivariate Analysis
2019
Heavy metal monitoring in food-producing ecosystems can play an important role in human health safety. Since they are able to interfere with plants’ physiochemical characteristics, which influence the optical properties of leaves, they can be measured by in-field spectroscopy. In this study, the predictive power of spectroscopic data is examined. Five treatments of heavy metal stress (Cu, Zn, Pb, Cr, and Cd) were applied to grapevine seedlings and hyperspectral data (350−2500 nm), and heavy metal contents were collected based on in-field and laboratory experiments. The partial least squares (PLS) method was used as a feature selection technique, and multiple linear regressions (…
Atmospheric and Instrumental Effects on the Fluorescence Remote Sensing Retrieval
2018
Accurately disentangling the tiny Solar–Induced Chlorophyll Fluorescence (SIF) from canopy reflected solar irradiance by using passive remote sensing techniques is always challenging. Regardless the scale at which SIF is measured, i.e., proximal sensing, airborne or satellite level; instrumental and atmospheric effects must be accounted for and compensated as part of the SIF retrieval strategy. Regarding the instrumental effects, the use of very high spectral resolution spectrometers makes mandatory an accurate characterization of the Instrument Spectral Response Function (ISRF); and – in the case of imager spectrometers – an accurate characterization of the full instrument response in the …
High‐resolution stimulated Raman spectroscopy and analysis of line positions and assignments for the ν 2 and ν 3 bands of 13 C 2 H 4
2016
High-resolution stimulated Raman spectra of13C2H4 in the regions of the ν2 and ν3 Raman active modes have been recorded at two temperatures (145 and 296 K) based on the quasi continuous-wave (cw) stimulated Raman spectrometer at Instituto de Estructura de la Materia IEM-CSIC in Madrid. A tensorial formalism adapted to X2Y4 planar asymmetric tops with D2h symmetry (developed in Dijon) and a program suite called D2hTDS (now part of the XTDS/SPVIEW spectroscopic software) were proposed to analyze and calculate the high-resolution spectra. A total of 103 and 51 lines corresponding to ν2 and ν3 Raman active modes have been assigned and fitted in wavenumber with a global root mean square deviatio…