Search results for "spectrometer"
showing 10 items of 751 documents
Study of Mode Competition in the Third Harmonic Gyrotron with Inclusion of the Electron Velocity Spread and the Beam Width
2018
Influence of the electron velocity spread and the beam width on the mode competition and efficiency is investigated in the 1.185- THz third harmonic gyrotron to be used in dynamical nuclear polarization - nuclear magnetic resonance (DNP-NMR) spectrometer.
Characterization of a Be(p,xn) Neutron Source for Fission Yields Measurements
2013
We report on measurements performed at The Svedberg Laboratory (TSL) to characterize a proton-neutron converter for independent fission yield studies at the IGISOL-JYFLTRAP facility (Jyv\"askyl\"a, Finland). A 30 MeV proton beam impinged on a 5 mm water-cooled Beryllium target. Two independent experimental techniques have been used to measure the neutron spectrum: a Time of Flight (TOF) system used to estimate the high-energy contribution, and a Bonner Sphere Spectrometer able to provide precise results from thermal energies up to 20 MeV. An overlap between the energy regions covered by the two systems will permit a cross-check of the results from the different techniques. In this paper, th…
First results from electrical qualification measurements on DEPFET pixel detector
2010
We report on the first results from a new setup for electrical qualification measurements of DEPFET pixel detector matrices. In order to measure the transistor properties of all pixels, the DEPFET device is placed into a benchtest setup and electrically contacted via a probecard. Using a switch matrix, each pixel of the detector array can be addressed individually for characterization. These measurements facilitate to pre-select the best DEPFET matrices as detector device prior to the mounting of the matrix and allow to investigate topics like the homogeneity of transistor parameters on device, wafer and batch level in order to learn about the stability and reproducibility of the production…
Spin polarisation and dichroism in ARUPS from thin rare earth films
2001
Abstract In the present study, spin polarisation and dichroism were investigated in angular resolved VUV photoemission ARUPS from magnetised as well as paramagnetic rare earth surfaces. Thin Gd(0001) films were prepared epitaxially on W(110). The photoelectrons were excited by polarised synchrotron radiation from the BESSY I synchrotron radiation source. A SPLEED detector attached to an electron spectrometer mounted on a single axis goniometer was used for angular resolved spin analysis. The main part of this work focused on the characteristic surface state of Gd(0001) which shows a splitting, as previously observed by linear magnetic dichroism and spin polarised photoemission. The spin ana…
Mass spectrometry of atomic ions produced by in-trap decay of short-lived nuclides
2005
The triple-trap mass spectrometer ISOLTRAP at ISOLDE/CERN has demonstrated the feasibility of mass spectrometry of in-trap-decay product ions. This novel technique gives access to radionuclides, which are not produced directly at ISOL-type radioactive ion beam facilities. As a proof of principle, the in-trap decay of $^{37}K^+$ has been investigated in a Penning trap filled with helium buffer gas. The half-life of the mother nuclide was confirmed and the recoiling $^{37}Ar^+$ daughter ion was contained within the trap. The ions of either the mother or the daughter nuclide were transferred to a precision Penning trap, where their mass was determined.
Position-sensitive ion detection in precision Penning trap mass spectrometry
2009
A commercial, position-sensitive ion detector was used for the first time for the time-of-flight ion-cyclotron resonance detection technique in Penning trap mass spectrometry. In this work, the characteristics of the detector and its implementation in a Penning trap mass spectrometer will be presented. In addition, simulations and experimental studies concerning the observation of ions ejected from a Penning trap are described. This will allow for a precise monitoring of the state of ion motion in the trap.
The X-ray Integral Field Unit (X-IFU) for Athena
2014
Athena is designed to implement the Hot and Energetic Universe science theme selected by the European Space Agency for the second large mission of its Cosmic Vision program. The Athena science payload consists of a large aperture high angular resolution X-ray optics (2 m2 at 1 keV) and twelve meters away, two interchangeable focal plane instruments: the X-ray Integral Field Unit (X-IFU) and the Wide Field Imager. The X-IFU is a cryogenic X-ray spectrometer, based on a large array of Transition Edge Sensors (TES), oering 2.5 eV spectral resolution, with approximately 5" pixels, over a field of view of 5' in diameter. In this paper, we present the X-IFU detector and readout electronics princi…
The mirror module design for the cryogenic x-ray imaging spectrometer on-board ORIGIN
2011
ORIGIN is a medium size high-energy mission concept submitted to ESA in response to the Cosmic Vision call issued on July 2010. The mission will investigate the evolution of the Universe by performing soft X-ray high resolution spectroscopic measurements of metals formed in different astrophysical environments, from the first population III stars at z > 7 to the present large scale structures. The main instrument on-board ORIGIN will be a large format array of TES X-ray micro-calorimeters covering a FOV of 30' at the focal plane of a grazing incidence optical module with a focal length of 2.5 m and an angular resolution of 30'' HEW at 1 keV. We present the optical module design which is bas…
Improved determination of the β−ν¯e angular correlation coefficient a in free neutron decay with the aSPECT spectrometer
2020
We report on a precise measurement of the electron-antineutrino angular correlation ($a$ coefficient) in free neutron beta-decay from the $a$SPECT experiment. The $a$ coefficient is inferred from the recoil energy spectrum of the protons which are detected in 4$\pi$ by the $a$SPECT spectrometer using magnetic adiabatic collimation with an electrostatic filter. Data are presented from a 100 days run at the Institut Laue Langevin in 2013. The sources of systematic errors are considered and included in the final result. We obtain $a = -0.10430(84)$ which is the most precise measurement of the neutron $a$ coefficient to date. From this, the ratio of axial-vector to vector coupling constants is …
A microcalorimeter spectrometer for the investigation of laboratory plasmas
2002
We describe a cryostat and 2-stage ADR specifically designed for making measurements at the NIST EBIT (Electron Beam Ion Trap) facility. The design is compact and consists of a single helium bath with two vapor-cooled shields. The 2-stage ADR has two separate magnets and two heat switches. The interface between the EBIT and microcalorimeter array will also be described.