Search results for "spectrometer"

showing 10 items of 751 documents

Search for long-lived particles produced in pp collisions at s=13  TeV that decay into displaced hadronic jets in the ATLAS muon spectrometer

2019

A search for the decay of neutral, weakly interacting, long-lived particles using data collected by the ATLAS detector at the LHC is presented. The analysis in this paper uses 36.1 fb(-1) of proton ...

PhysicsLarge Hadron ColliderPhysics::Instrumentation and Detectors010308 nuclear & particles physicsAtlas (topology)Atlas detectorHadronAtlas muon spectrometer01 natural sciencesNuclear physicsMuon spectrometer0103 physical sciencesHiggs bosonHigh Energy Physics::Experiment010306 general physicsPhysical Review D
researchProduct

Towards a "perfect" Penning trap mass spectrometer for unstable isotopes

1992

A Penning trap mass spectrometer has been set up at the on-line isotope separator ISOLDE/CERN for the mass determination of unstable heavy isotopes. The spectrometer should fulfil the following requirements: capture of external ions in high efficiency, high resolving power and accuracy, general applicability to all elements and isotopes available at the on-line facility.

PhysicsLarge Hadron ColliderSpectrometerIsotopePhysics::Instrumentation and DetectorsSeparator (oil production)Condensed Matter PhysicsMass spectrometryPenning trapAtomic and Molecular Physics and OpticsIonNuclear physicsPhysics::Accelerator PhysicsPhysics::Atomic PhysicsAtomic physicsNuclear ExperimentMathematical PhysicsPhysica Scripta
researchProduct

Tests and developments of the PANDA Endcap Disc DIRC

2016

The PANDA experiment at the future Facility for Antiproton and Ion Research (FAIR) requires excellent particle identification. Two different DIRC detectors will utilize internally reflected Cherenkov light of charged particles to enable the separation of pions and kaons up to momenta of 4 GeV/c. The Endcap Disc DIRC will be placed in the forward endcap of PANDA's central spectrometer covering polar angles between 5° and 22°. Its final design is based on MCP-PMTs for the photon detection and an optical system made of fused silica. A new prototype has been investigated during a test beam at CERN in May 2015 and first results will be presented. In addition a new synthetic fused silica material…

PhysicsLarge Hadron ColliderSpectrometerPhysics::Instrumentation and Detectors010308 nuclear & particles physicsDetectorRadiation01 natural sciencesCharged particleParticle identificationNuclear physics0103 physical sciencesFacility for Antiproton and Ion ResearchHigh Energy Physics::ExperimentNuclear Experiment010306 general physicsInstrumentationMathematical PhysicsCherenkov radiationJournal of Instrumentation
researchProduct

Coulomb Excitation of (142) Xe

2017

5 pags., 2 figs. -- Open Access funded by Creative Commons Atribution Licence 4.0. -- Presented at the XXXV Mazurian Lakes Conference on Physics, Piaski, Poland, September 3–9, 2017.

PhysicsLarge Hadron ColliderSpectrometerta114010308 nuclear & particles physicsDetectorNuclear TheoryGeneral Physics and AstronomyksenonCoulomb excitation[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]01 natural sciencesxenonNuclear physicsnuclear physics0103 physical sciencesQuadrupolePhysics::Accelerator PhysicsNuclear Physics - ExperimentMAGIC (telescope)ydinfysiikkaNuclear ExperimentBeam (structure)
researchProduct

Retrieval of sun-induced fluorescence using advanced spectral fitting methods

2015

Abstract The FLuorescence EXplorer (FLEX) satellite mission, candidate of ESA's 8th Earth Explorer program, is explicitly optimized for detecting the sun-induced fluorescence emitted by plants. It will allow consistent measurements around the O2-B (687 nm) and O2-A (760 nm) bands, related to the red and far-red fluorescence emission peaks respectively, the photochemical reflectance index, and the structural-chemical state variables of the canopy. The sun-induced fluorescence signal, overlapped to the surface reflected radiance, can be accurately retrieved by employing the powerful spectral fitting technique. In this framework, a set of fluorescence retrieval algorithms optimized for FLEX ar…

PhysicsMETIS-314125Spectrometerbusiness.industryRetrieval algorithmSpectral fitting methodSoil ScienceGeologyFull fluorescence spectrumPhotochemical Reflectance IndexFluorescenceSpectral linen/a OA procedureFLEX missionOpticsSun-induced fluorescenceRadianceRadiative transferSatelliteComputers in Earth SciencesbusinessAbsorption (electromagnetic radiation)Remote sensing
researchProduct

Gamow-Teller strengths in proton-rich exotic nuclei deduced in the combined analysis of mirror transitions

2005

Isospin symmetry is expected for the T-z=+/- 1 -> 0 isobaric analogous transitions in isobars with mass number A, where T-z is the z component of isospin T. Assuming this symmetry, strengths of analogous Gamow-Teller (GT) transitions within A=50 isobars were determined from a high energy-resolution T-z=+1 -> 0, Cr-50(He-3,t)Mn-50 study at 0 degrees in combination with the decay Q value and lifetime from the T-z=-1 -> 0, Fe-50 ->Mn-50 beta decay. This method can be applied to other pf-shell nuclei and can be used to study GT strengths of astrophysical interest.

PhysicsMass numberProtonQ valueRCNPNuclear TheoryGeneral Physics and AstronomySYMMETRY-STRUCTUREBeta decayNuclear physicsHelium-3IsospinDouble beta decayBEAM LINEIsobarAtomic physicsBETA-DECAYWEAKNuclear ExperimentSPECTROMETER GRAND RAIDENPhysical Review Letters
researchProduct

Fine structure in the beta-delayed proton decay of 33Ar

1996

9 pages, 2 figures, 2 tables.-- PACS nrs.: 21.60.Cs; 23.40.−s; 27.30.+t; 29.30.Ep.

PhysicsMeasured beta-delayed protons Ep IpNuclear and High Energy PhysicsDeduced relative spectroscopic amplitudesAr-33 (from 1 GeV p on Nb-foil target selective mass separation)Proton decaySHELL modelShell nucleiShell-model calculationGas-Si telescope spectrometerShell modelEmissionBeta-delayed proton decayAmplitudeAtomic orbitalExcited stateBeta (plasma physics)Nuclear Physics - ExperimentAtomic physicsNuclear Physics A
researchProduct

Test Measurements of Modernized Version of Two-Detector Doppler Spectrometer

1999

The quality of the annihilation quanta energy measurements (Doppler effect) has greatly increased when experimenters have begun to introduce Doppler apparatus modifications. In the basic version, the experimental set-up consisted of high energy resolution Ge(Li) detector, amplifier and multichannel analyser. A simple construction and short time of data acquisition were the main advantages of that version of the apparatus. Competitive, angular correlation of annihilation radiation (ACAR) method was better from the resolution point of view and not worse when considering the range of momentum distribution, but the ACAR method required high activity positron sources and data acquisition time wa…

PhysicsMomentumsymbols.namesakePositronPhotonAnnihilationSpectrometerAnnihilation radiationDetectorsymbolsGeneral Physics and AstronomyDoppler effectComputational physicsActa Physica Polonica A
researchProduct

Spectroscopy of the neutron-deficient isobars 163 Re and 163 W using tagging techniques

2008

Bozok University;Erciyes University;et al.;Istanbul University;Nigde University;The Turkish Atomic Energy Authority (TAEK)

PhysicsNuclear Reactions 60 Ni+ 106 Cd at 270 MeV beam energy enriched targetsSpectrometerProtonYrastNuclear TheorySegmented Si and Ge detectorsNeutron spectroscopyNuclear physicsMeasured E ?IsobarNeutronGasfilled recoil separatorNuclear ExperimentGround stateRadioactive decay
researchProduct

A digital approach for real time high-rate high-resolution radiation measurements

2014

Abstract Modern spectrometers are currently developed by using digital pulse processing (DPP) systems, showing several advantages over traditional analog electronics. The aim of this work is to present digital strategies, in a time domain, for the development of real time high-rate high-resolution spectrometers. We propose a digital method, based on the single delay line (SDL) shaping technique, able to perform multi-parameter analysis with high performance even at high photon counting rates. A robust pulse shape and height analysis (PSHA), applied on single isolated time windows of the detector output waveforms, is presented. The potentialities of the proposed strategy are highlighted thro…

PhysicsNuclear and High Energy PhysicsAnalogue electronicsSpectrometerDetectorSettore FIS/01 - Fisica SperimentalePhoton countingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Semiconductor detectorPulse (physics)Digital pulse processing Pulse height analysis Pulse shape analysis Real time processing Dead time correction Energy resolved photon countingElectronic engineeringWaveformTime domainInstrumentation
researchProduct