Search results for "spectrometer"

showing 10 items of 751 documents

A ten-fold divided total absorption Ge(Li) gamma-ray detector

1976

Abstract We have constructed a split-crystal total absorption Ge(Li) gamma-ray spectrometer and special logic electronics for rejecting Compton continuum in spectra. A 10 cm3 planar detector was divided into ten electrically separated detectors by grinding nine parallel slots on the n-surface of the detector. In operation both the n- and p-contacts are isolated from the ground. Using capacitive sharing, most of the released electrical charge is taken from the p-contact into an ordinary pulse amplifier line and analyzed. A small fraction of the charge collected at the n-strips is observed with voltage-sensitive FET-preamplifiers. The following logic electronics provides a gate pulse for the …

PhysicsSpectrum analyzerSpectrometerPhysics::Instrumentation and Detectorsbusiness.industryAmplifierDetectorCompton scatteringGeneral MedicineElectric chargeSpectral lineNuclear physicsOpticsPhase detector characteristicbusinessNuclear Instruments and Methods
researchProduct

Strongly coupled bands in the neutron-deficient nucleus167Re

2003

Excited states in the neutron-deficient nucleus Re-167 have been observed in a recoil-tagging experiment performed with the Jurosphere gamma-ray spectrometer in conjunction with the RITU gas-filled ...

PhysicsStrongly coupledNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and DetectorsAstrophysics::High Energy Astrophysical PhenomenaConjunction (astronomy)Nuclear TheoryNuclear physicsmedicine.anatomical_structureExcited statemedicineNeutronAtomic physicsNuclear ExperimentNucleusPhysical Review C
researchProduct

A solenoid retarding spectrometer with high resolution and transmission for keV electrons

1992

Abstract We have built an electrostatic electron spectrometer combining both high resolution and large luminosity. The instrument consists essentially of two superconducting solenoids separated by a system of ring electrodes of 4 m in length. Source and detector are placed in the high-field regions of the superconducting solenoids, whereas the repellent analyzing electrostatic potential of the ring electrodes peaks at the minimum of the magnetic field in between these solenoids. The magnetic guiding field provides (i) the acceptance of the full foreward solid angle of 2π, (ii) the transformation of the transverse cyclotron motion into longitudinal motion parallel to the magnetic field. The …

PhysicsSuperconductivityNuclear and High Energy PhysicsElectron spectrometerField (physics)SpectrometerCyclotronSolenoidElectronlaw.inventionMagnetic fieldlawAtomic physicsInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Backtracing particle rays through magnetic spectrometers: avoiding systematic errors in the reconstruction of target coordinates

1993

Abstract The procedures used to model [J. Friedrich, Nucl. Instr. and Meth. A 293 (1990) 575] or to determine [N. Voegler et al., Nucl. Instr. and Meth. A 249 (1986) 337, H. Blok et al., ibid., vol. A 262 (1987) 291, and E.A.J.M. Offermann et al., ibid., vol. A 262 (1987) 298] the mapping properties of a magnetic spectrometer are based on a minimization of the variance of target coordinates . We show that backtracing with matrix elements, determined in this way, may contain systematic errors. As alternative, we propose to minimize the variance of the detector coordinates . This procedure avoids these systematic errors.

PhysicsSystematic errorNuclear and High Energy PhysicsMatrix (mathematics)OpticsSpectrometerbusiness.industryDetectorParticlebusinessInstrumentationComputational physicsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Double pi(0) photoproduction off the proton at threshold

2003

The reaction $\gamma p \to \pi^0 \pi^0 p$ has been measured using the TAPS BaF$_2$ calorimeter at the tagged photon facility of the Mainz Microtron accelerator. Chiral perturbation theory (ChPT) predicts that close to threshold this channel is significantly enhanced compared to double pion final states with charged pions. In contrast to other reaction channels, the lower order tree terms are strongly suppressed in 2$\pi^0$ photoproduction. The consequence is the dominance of pion loops in the 2$\pi^0$ channel close to threshold - a result that opens new prospects for the test of ChPT and in particular its inherent loop terms. The present measurement is the first which is sensitive enough fo…

PhysicsTAPSNuclear and High Energy PhysicsParticle physicsChiral perturbation theoryMesonProtonNuclear TheoryHigh Energy Physics::LatticeNEUTRAL-PION-PHOTOPRODUCTIONHadronNuclear TheoryElementary particleCHIRAL PERTURBATION-THEORYNuclear physicsPionTAGGED PHOTON SPECTROMETERNucleonNuclear ExperimentMicrotronNuclear Experiment
researchProduct

Secondary electron flight times and tracks in the carbon foil time pick-up detector

2014

Carbon foil time pick-up detectors used in the time-of-flight measurements of MeV energy ions have been studied in connection to time-of-flight-energy spectrometer used for heavy ion elastic recoil detection analysis. In experimental coincident TOF-E data characteristic halos are observed around light element isobars, and the origin of these halos were studied. The experimental data indicated that these halos originate from single electron events occurring before the electron multiplication in the microchannel plate. By means of electron trajectory simulations, this halo effect is explained to originate from single electron, emitted from the carbon foil, hitting the non-active area of the m…

PhysicsToF-ERDANuclear and High Energy Physicstiming gateta114business.industryPhysics::Instrumentation and DetectorsDetectorElectrontime-of-flightSecondary electronsElastic recoil detectionTime of flightOpticsCoincidentMicrochannel plate detectorspectrometerAtomic physicsbusinesscarbon foil time pick-up detectorInstrumentationFOIL methodNuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
researchProduct

The use of the integral-bias summing coincidence spectrometer in directional correlation measurements

1968

Abstract The performance of the integral-bias summing coincidence spectrometer (the sum-peak spetrometer) in measurements of directional correlations of gamma rays has been tested. As compared with the conventional method, the sum-peak spectrometer is easier to use and seems to yield results which agree with those obtained with the ordinary method. Because of the complex shapes of response functions of gamma rays above about 3 MeV, the new method is best suited to the study of cascading transitions below this energy, where the two methods appear to complement each other. The analysis of the sum-peak spectra in the present work is based on a simple graphical method which seems to yield satis…

PhysicsWork (thermodynamics)Spectrometer010308 nuclear & particles physicsGamma rayGeneral Medicine01 natural sciencesCoincidenceSpectral lineNuclear physicsYield (chemistry)0103 physical sciences010306 general physicsEnergy (signal processing)Complement (set theory)Nuclear Instruments and Methods
researchProduct

An Active X-Ray Spectrometer for the SELENE-2 Rover

2014

The Active X-ray Spectrometer (AXS) for the Japanese SELENE-2 rover has been proposed for elemental analysis on the lunar surface to measure the major elements: Mg, Al, Si, Ca, Ti, and Fe; the minor elements, Na, K, P, S, Cl, Cr, and Mn and the trace element Ni, all depending on their concentrations at a landing site. The elemental data of the AXS allow us to not only classification but also quantification of surface rocks on the Moon. The AXS is a compact low-weight instrument for elemental analysis based on the principle of X-ray fluorescence spectrometry using an X-ray spectrometer and two (four) pyroelectric crystals as X-Ray Generators (XRG). This paper introduces the current status of…

PhysicsX-ray spectroscopySpectrometerElemental analysisAnalytical chemistrySurface roughnessTrace elementFluorescence spectrometryFluxPyroelectricityRemote sensingTRANSACTIONS OF THE JAPAN SOCIETY FOR AERONAUTICAL AND SPACE SCIENCES, AEROSPACE TECHNOLOGY JAPAN
researchProduct

High Energy, High Resolution X-Ray Spectroscopy: Microcalorimeters For Nuclear Line Astrophysics

2005

We introduce focusing optics and microcalorimeter spectroscopy to nuclear line emission astrophysics with a balloon payload concept called, B‐MINE. It is designed to probe the deepest regions of a supernova explosion by detecting 44Ti emission at 68 keV with spatial and spectral resolutions that are sufficient to determine the velocity distribution of the 44Ti emitting region. B‐MINE has a thin plastic foil telescope multilayered to maximize the reflectivity in a 20 keV band centered at 68 keV and a microcalorimeter array optimized for the same energy band. This combination provides a reduced background, an energy resolution of 50 eV and a 3σ sensitivity in 106 s of 6 × 10−8 ph cm−2 s−1 at …

PhysicsX-ray spectroscopySpectrometerPhysics::Instrumentation and Detectorsbusiness.industryAstrophysics::High Energy Astrophysical PhenomenaResolution (electron density)Astrophysicslaw.inventionTelescopeSupernovaOpticslawEmission spectrumSpectroscopybusinessX- and gamma-ray telescopes and instrumentation Photometric polarimetric and spectroscopic instrumentationLine (formation)
researchProduct

Characterization of Al-Schottky CdTe detectors

2011

In the last decades, great efforts are being devoted to the development of CdTe detectors for high resolution X-ray and gamma ray spectroscopy. Recently, new rectifying contacts based on aluminum (Al) are very appealing in the development of CdTe detectors with low leakage currents and anode pixellization. In this work, we report on preliminary results of electrical and spectroscopic investigations on Schottky CdTe diode detectors (4.1 × 4.1 × 0.75 and 4.1 × 4.1 × 2 mm3) with Au/Ti/Al/CdTe/Pt electrode configuration. The detectors are characterized by very low leakage currents even at room temperature (26 pA at 25 °C under a bias voltage of −100 V for the 2 mm thick detector). Polarization …

PhysicsX-ray spectroscopySpectrometerbusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorSchottky diodeBiasingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)AnodeCdTe detectorFull width at half maximumX-ray and gamma ray spectroscopyOpticsOptoelectronicsGamma spectroscopybusiness2011 IEEE Nuclear Science Symposium Conference Record
researchProduct