Search results for "spektroskopia"
showing 10 items of 196 documents
Total absorption γ -ray spectroscopy of niobium isomers
2019
15 pags. 17 figs., 5 tabs.
Penning-trap mass measurements on 92, 94-98, 100Mo with JYFLTRAP
2012
Penning-trap measurements on stable 92, 94-98, 100Mo isotopes have been performed with relative accuracy of \ensuremath1⋅10−8\ensuremath1⋅10−8 with the JYFLTRAP Penning-trap mass spectrometer by using 85Rb as a reference. The Mo isotopes have been found to be about 3keV more bound than given in the Atomic Mass Evaluation 2003 (AME03). The results confirm that the discrepancy between the ISOLTRAP and JYFLTRAP data for 101-105Cd isotopes was due to an erroneous value in the AME03 for 96Mo used as a reference at JYFLTRAP. The measured frequency ratios of Mo isotopes have been used to update mass-excess values of 30 neutron-deficient nuclides measured at JYFLTRAP. peerReviewed
Real-time Fluorescence Measurement of Enterovirus Uncoating
2019
Viruses need to open, i.e., uncoat, in order to release their genomes for efficient replication and translation. Especially for non-enveloped viruses, such as enteroviruses, the cues leading to uncoating are less well known. The status of the virus has previously been observed mainly by transmission electron microscopy using negative staining, cryo electron microscopy, X-ray crystallography or gradient separation (reviewed in Tuthill et al., 2010, Myllynen et al., 2016, Ruokolainen et al., 2019). However, monitoring of uncoating has been limited by the lack of methods detecting dynamic changes of the virions. Here, we present a real-time fluorescence based protocol, which detects the viral …
Spectroscopic Tools Applied to Flerovium Decay Chains
2020
Abstract An upgraded TASISpec setup, with the addition of a veto DSSD and the new Compex detector-germanium array, has been employed with the gas-filled recoil separator TASCA at the GSI Helmholtzzentrum für Schwerionenforschung Darmstadt, to study flerovium (element 114) decay chains. The detector upgrades along with development of new analytical techniques have improved the sensitivity of the TASISpec setup for measuring α-photon coincidences. These improvements have been assessed with test reactions. The reaction 48Ca+206,207Pb was used for verification of experimental parameters such as transmission to implantation DSSD and target-segment to α-decay correlations. The reaction 48Ca+ nat …
Simultaneous non-invasive gas analysis in artificial photosynthesis reactions using rotational Raman spectroscopy
2022
Optimising reactions in artificial photosynthesis research requires screening of many reaction and operation parameters, which is often resource-intense and time-consuming. In this paper, we demonstrate the use of a rotational Raman-based spectrometer for non-invasive quantification of several gases (H2, O2, N2, CO, CO2) with short analysis times (15 s), enabling high throughput screening. Furthermore, with this device, reaction progress can be monitored in situ, by real-time simultaneous quantification of multiple gases. We have applied this instrument and developed a method to study the O2 dependency of a prototypic light-driven hydrogen evolution reaction, showcasing the value of this ap…
The NUMEN project @ LNS: Status and perspectives
2017
The NUMEN project aims at accessing experimentally driven information on Nuclear Matrix Elements (NME) involved in the half-life of the neutrinoless double beta decay (0νββ), by high-accuracy measurements of Heavy Ion (HI) induced Double Charge Exchange (DCE) reaction cross sections. In particular, the (18O,18Ne) and (20Ne,20O) reactions are used as tools for β+β+ and β−β− decays, respectively. In the experiments, performed at INFN - Laboratory Nazionali del Sud (LNS) in Catania, the beams are accelerated by the Superconducting Cyclotron (CS) and the reaction ejectiles are detected the MAGNEX magnetic spectrometer. The measured cross sections are challengingly low (a few nb), being the tota…
First demonstration of Doppler-free 2-photon in-source laser spectroscopy at the ISOLDE-RILIS
2020
Abstract Collinear Doppler-free 2-photon resonance ionization has been applied inside a hot cavity laser ion source environment at CERN-ISOLDE. An injection-seeded Ti:sapphire ring laser was used to generate light pulses with a Fourier-limited linewidth for high-resolution spectroscopy. Using a molybdenum foil as a reflective surface positioned at the end of the target transfer line, rubidium was successfully ionized inside the hot cavity. The results are presented alongside previously obtained data from measurements performed at the RISIKO mass separator at Mainz University, where collinear and perpendicular ionization geometries were tested inside an RFQ ion guide. This work is a pre-curs…
Combined electrical transport and Raman measurements of individual single-walled carbon nanotubes
2009
Gamma-ray spectroscopy of191,193Bi
2001
Very neutron-deficient Bi-191,Bi-193 nuclei have been studied at the Department of Physics, University of Jyvaskyla, Finland (JYFL) employing the Jurosphere II Ge-detector array coupled to the gas-filled recoil separator RITU and different tagging techniques. For the first time in heavy odd-mass nuclei, a collective band (oblate) is identified above the 2p-1h (1/2(+)) proton intruder state in Bi-191. In both Bi-191,Bi-193, a band based on isomeric 13/2(+) state has been observed and oblate deformation for this state has been deduced. ispartof: Acta Physica Polonica B vol:32 issue:3 pages:1019-1023 ispartof: location:POLAND, ZAKOPANE status: published
Kultapinnan S(CH2)xN3-adsorbaattien laskennallinen värähdysdynamiikka ja 2DIR-spektroskopia molekyylidynamiikkamenetelmin
2018
Tehtiin MD-simulaatiot kultapinnan siltapaikkoihin kahdella eri peitolla (1/3 ja 1/4) yksikerrokseksi asetetuille pitkä- ja lyhytketjuisille S(CH2)xN3-adsorbaateille (x = 2, 11). Kukin systeemi simuloitiin sekä tyhjiössä että vesiympäristössä. Simulaatioista määritettiin atsidiryhmien FFCF:t ja CLS:t odotusaikavälille t2 ∈ [0, 200] ps. Näihin sovitettiin multieksponentiaaliset funktiot ja havaittiin FFCF:n hitaiden komponenttien vastaavan CLS-komponentteja. Lisäksi tarkasteltiin mallia, joka esittää CLS:n ja FFCF:n välille suoraviivaisen yhteyden ja mahdollistaa Lorentzin ja Gaussin leveyksien määrittämisen. Malli todettiin hyvin toimivaksi simulaatioista saatujen tulosten tapauksessa. MD s…