Search results for "sperimentale"

showing 10 items of 938 documents

Proprietà e applicazioni a microonde del MgB2

2008

Superconductivity MgB2 microwave resonant cavitySettore FIS/01 - Fisica Sperimentale
researchProduct

Effect of boron doping in the microwave surface resistance of neutron irradiated melt-textured Y1.6Ba2.3Cu3.3O7−x samples

2012

We report on the microwave surface resistance of melt-textured Y_1.6Ba_2.3Cu_3.3O_7-x samples, doped with different amount of B_2O_3 and, subsequently, irradiated by thermal neutrons at the fluence of 1.476 \times 10^17 cm^-2. The microwave surface resistance has been measured as a function of temperature and DC magnetic field. The experimental results are quantitatively discussed in the framework of the Coffey and Clem theory, properly adapted to take into account the d-wave nature of cuprate superconductors. By fitting the experimental data at zero DC field, we have highlighted the effects of the induced defects in the general properties of the samples, including the intergranular region.…

SuperconductivityB2O3 additionMaterials scienceCondensed matter physicsFluxonCondensed Matter - SuperconductivitySettore FIS/01 - Fisica SperimentaleDopingFOS: Physical sciencesEnergy Engineering and Power TechnologyThermal-neutron irradiationCondensed Matter PhysicsFluenceNeutron temperatureElectronic Optical and Magnetic MaterialsMagnetic fieldSuperconductivity (cond-mat.supr-con)Depinning frequency; Microwave surface resistance; Thermal-neutron irradiationCondensed Matter::SuperconductivityMicrowave surface resistanceCuprateDepinning frequencyElectrical and Electronic EngineeringMicrowavePhysica C: Superconductivity
researchProduct

Microwave response of a cylindrical cavity made of bulk MgB2 superconductor

2008

We report on the microwave properties of a resonant cylindrical cavity made of bulk MgB2 superconductor, produced by the reactive liquid Mg infiltration process. The frequency response of the cavity has been measured in the range 5-13GHz. Among the various modes, the TE011, resonating at 9.79GHz, exhibits the highest quality factor. For this mode, we have determined the temperature dependence of the quality factor, obtaining values of the order of 10^5 in the temperature range 4.2-30K. The values of the surface resistance deduced from the measurements of the quality factor agree quite well with those independently measured in a small sample of MgB2 extracted from the same specimen from whic…

SuperconductivityFrequency responseMaterials scienceCondensed matter physicsMgB2Condensed Matter - SuperconductivitySettore FIS/01 - Fisica SperimentaleFOS: Physical sciencesEnergy Engineering and Power TechnologyAtmospheric temperature rangeCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsSuperconducting microwave cavitySuperconductivity (cond-mat.supr-con)Surface conductivityQuality (physics)Surface resistanceElectrical and Electronic EngineeringSheet resistanceMicrowaveMicrowave cavity
researchProduct

Near-Tc second-harmonic emission in high-density bulk MgB2 at microwave frequency

2006

We discuss the microwave second-harmonic generation in high-density bulk MgB2, prepared by the reactive liquid Mg infiltration technology. The intensity of the harmonic signal has been investigated as a function of temperature and amplitudes of the DC and microwave magnetic fields. The results are discussed in the framework of a phenomenological theory, based on the two-fluid model, which assumes that both the microwave and static magnetic fields, penetrating in the surface layers of the sample, weakly perturb the partial concentrations of the normal and superconducting fluids. We show that, in order to account for the experimental results, it is essential to suppose that in MgB2 the densit…

SuperconductivityMaterials scienceCondensed matter physicsCondensed Matter - SuperconductivitySettore FIS/01 - Fisica SperimentaleFOS: Physical sciencesHigh densityMicrowave frequencyCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsMagnetic fieldSuperconductivity (cond-mat.supr-con)AmplitudeCondensed Matter::SuperconductivityNear-TcMicrowave
researchProduct

Superconducting Microwave Cavity Made of Bulk MgB2

2006

We report the successful manufacture and characterization of a microwave resonant cylindrical cavity made of bulk MgB2 superconductor (Tc = 38.5 K), which has been produced by the Reactive Liquid Mg Infiltration technique. The quality factor of the cavity for the TE011 mode, resonating at 9.79 GHz, has been measured as a function of the temperature. At T = 4.2 K, the unloaded quality factor is 2.2x10^5; it remains of the order of 10^5 up to T ~ 30 K. We discuss the potential performance improvements of microwave cavities built from bulk MgB2 materials produced by reactive liquid Mg infiltration.

SuperconductivityMaterials scienceCondensed matter physicsCondensed Matter - SuperconductivitySettore FIS/01 - Fisica SperimentaleMetals and AlloysFOS: Physical sciencesCondensed Matter PhysicsInfiltration (HVAC)Superconductivity (cond-mat.supr-con)INFILTRATIONMaterials ChemistryCeramics and CompositesMAGNESIUM DIBORIDEElectrical and Electronic EngineeringMicrowaveMicrowave cavity
researchProduct

Anomalous magnetic hysteresis in the microwave surface resistance of MgB2 superconductor

2007

We report experimental results of the field-induced variations of the microwave surface resistance in samples of MgB2, produced by different methods. By sweeping the DC magnetic field at increasing and decreasing values, we have detected a magnetic hysteresis that can be ascribed to the different magnetic induction, due to the critical state of the fluxon lattice. The hysteresis observed in the bulk samples has an unusual shape, which cannot be justified in the framework of the critical-state models.

SuperconductivitySuperconductivityHistoryMicrowave surface resistanceMaterials scienceCondensed matter physicsFluxonMgB2Condensed Matter - SuperconductivitySettore FIS/01 - Fisica SperimentaleFOS: Physical sciencesMagnetic hysteresismicrowave surface impedanceComputer Science ApplicationsEducationElectromagnetic inductionMagnetic fieldSuperconductivity (cond-mat.supr-con)Lattice (order)Bulk samplesCondensed Matter::Superconductivity
researchProduct

Effects of Weak Links in the Nonlinear Microwave Response of MgB2 Superconductor

2006

We report experimental results of second-harmonic (SH) response at microwave frequency in several ceramic MgB2 samples, prepared by different methods. The SH signal has been investigated as a function of the temperature and DC magnetic field. The investigation has been carried out at low magnetic fields, where nonlinear processes arising from motion of Abrikosov fluxons are ineffective. We show that the low-temperature SH emission is ascribable to processes involving weak links. Comparison among the peculiarities of the SH signal radiated by the different samples shows that the presence of weak links strongly depends on the sample preparation method, as well as the purity and morphology of …

Superconductivitymicrowave responseCondensed Matter - Materials ScienceMaterials scienceCondensed matter physicsCondensed Matter - SuperconductivitySettore FIS/01 - Fisica SperimentaleMicrowave responseMaterials Science (cond-mat.mtrl-sci)FOS: Physical sciencesMicrowave frequencyCondensed Matter Physicsweak links.SignalElectronic Optical and Magnetic MaterialsMagnetic fieldharmonic generationSuperconductivity (cond-mat.supr-con)Nonlinear systemmagnesium diboridevisual_artCondensed Matter::Superconductivityvisual_art.visual_art_mediumSample preparationCeramic
researchProduct

Commissioning of the ATLAS Muon Spectrometer with cosmic rays

2010

The ATLAS detector at the Large Hadron Collider has collected several hundred million cosmic ray events during 2008 and 2009. These data were used to commission the Muon Spectrometer and to study the performance of the trigger and tracking chambers, their alignment, the detector control system, the data acquisition and the analysis programs. We present the performance in the relevant parameters that determine the quality of the muon measurement. We discuss the single element efficiency, resolution and noise rates, the calibration method of the detector response and of the alignment system, the track reconstruction efficiency and the momentum measurement. The results show that the detector i…

SystemAstrofísicaDriftPhysics - Instrumentation and DetectorsMuon SpectrometerPhysics and Astronomy (miscellaneous)Physics::Instrumentation and DetectorsTracking (particle physics)01 natural sciences7. Clean energyHigh Energy Physics - ExperimentDrift TubeMDTHigh Energy Physics - Experiment (hep-ex)Data acquisitionATLAS muon spectrometer[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Detectors and Experimental TechniquesNuclear ExperimentPhysicsLarge Hadron Collidercosmic ray eventsDetectorSettore FIS/01 - Fisica SperimentaleBeamInstrumentation and Detectors (physics.ins-det)ATLASmedicine.anatomical_structureTrack ReconstructionPhysical SciencesFísica nuclearLHCmuon measurementFOS: Physical sciencesCosmic rayddc:500.2530Nuclear physicsAtlas (anatomy)0103 physical sciencesCalibrationmedicineFysikddc:530High Energy Physics[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsEngineering (miscellaneous)Ciencias ExactasMuonChambersMuon TrackCosmologiaATLAS detector010308 nuclear & particles physicsFísicaTrack SegmentPhysics::Accelerator Physicsproton-proton collisionsHigh Energy Physics::Experiment
researchProduct

Readiness of the ATLAS Tile Calorimeter for LHC collisions

2010

67 páginas.-- El PDF es la versión pre-print (arXiv:1007.5423v2).-- The ATLAS Collaboration.-- et al.

SystemPhysics - Instrumentation and DetectorsPhysics and Astronomy (miscellaneous)Physics::Instrumentation and DetectorsPerformance7. Clean energy01 natural sciences030218 nuclear medicine & medical imagingSettore FIS/04 - Fisica Nucleare e SubnucleareHigh Energy Physics - ExperimentHigh Energy Physics - Experiment (hep-ex)0302 clinical medicine[PHYS.HEXP]Physics [physics]/High Energy Physics - Experiment [hep-ex]Detectors and Experimental TechniquesDetectors de radiaciócosmic rayPhysicsLarge Hadron ColliderDetectorSettore FIS/01 - Fisica SperimentaleAstrophysics::Instrumentation and Methods for AstrophysicsInstrumentation and Detectors (physics.ins-det)ATLASmedicine.anatomical_structureScintillatorsPhysical Sciencesmagnetic-fields; scintillators; electronics; performance; systemLHCCol·lisionadors d'hadronsPhotomultiplierFOS: Physical sciencesCosmic rayddc:500.2Noise (electronics)530LHC collisions; AtlasNuclear physics03 medical and health sciencesAtlas (anatomy)0103 physical sciencesCalibrationmedicinetile hadronic calorimeterFysikddc:530High Energy Physics[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]010306 general physicsEngineering (miscellaneous)Ciencias ExactasCalorimeter (particle physics)010308 nuclear & particles physicsFísicaMagnetic-FieldsHigh Energy Physics::ExperimentElectronics
researchProduct

ALANINE/EPR DOSIMETRY APPLIED TO THE VALIDATION OF A TOTAL BODY IRRADIATION (TBI) PROTOCOL AND TREATMENT PLANNING DOSE CALCULATION USING A HUMANOID P…

2015

L’irraggiamento a corpo intero (Total Body Irradiation - TBI) è una tecnica di radioterapia oncologica di largo impiego nella clinica ematoncologica nell’ambito del trattamento di pazienti avviati al trapianto di midollo osseo o al trapianto di cellule staminali periferiche. La TBI da una parte permette di sopprimere il sistema immunitario del ricevente per prevenire il rigetto del midollo del donatore ed eliminare le cellule neoplastiche residue dai trattamenti chemioterapici. In genere, la modalità di somministrazione della TBI prevede irraggiamenti in 3 giorni consecutivi con un bi-frazionamento giornaliero (2 Gy, 2 volte al giorno con intervallo minimo di 6 ore tra le sedute, per 3 gior…

TBI Alanine ESR EPR Gamma photonsSettore FIS/01 - Fisica SperimentaleSettore MED/36 - Diagnostica Per Immagini E RadioterapiaSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct