Search results for "standard deviation"

showing 10 items of 282 documents

Immobilization of reagents by polymeric materials. Determination of metamizol

1992

Abstract A method for immobilization of inorganic reagents, based on the dispersion of the reagent into an unsaturated polyester solution is applied to immobilization of lead dioxide. The obtained solid is of application in a flow-injection manifold for indirect atomic absorption determination of metamizol in pharmaceutical formulations. The procedure gives a linear calibration graph up to 6 ppm of metamizol with a relative standard deviation of 1.6% (3.0 mg/l) and a sample throughput of 72 hr−1.

ChromatographyCalibration curveChemistryRelative standard deviationUnsaturated polyesterLead dioxideAnalytical Chemistrylaw.inventionchemistry.chemical_compoundlawReagentAtomic absorption spectroscopyDispersion (chemistry)Nuclear chemistryTalanta
researchProduct

Determination of trichothecenes in chicken liver using gas chromatography coupled with triple-quadrupole mass spectrometry

2018

Abstract Chicken meat and edible offal are included in a wide number of preparations in the worldwide cuisine. Among the offal, the liver is one of the most consumed in some countries like Egypt since it is rich in proteins and is an economical source of many essential nutrients for humans. Mycotoxins, secondary toxic metabolites produced by fungi, have the potential to enter human food chain not only with cereal consumption but also through edible tissues from animals fed with mycotoxin-contaminated feed. Accordingly, a rapid method for the determination of eight trichothecenes in chicken liver was developed based on a quick, easy, cheap, effective, rugged and safe (QuEChERS) extraction an…

ChromatographyChemistryExtraction (chemistry)Relative standard deviation04 agricultural and veterinary sciencesQuechersTandem mass spectrometry040401 food sciencechemistry.chemical_compound0404 agricultural biotechnologyChicken LiverTriple quadrupole mass spectrometryGas chromatographyMycotoxinFood ScienceLWT
researchProduct

New approaches based on modified Gaussian models for the prediction of chromatographic peaks

2012

Abstract The description of skewed chromatographic peaks has been discussed extensively and many functions have been proposed. Among these, the Polynomially Modified Gaussian (PMG) models interpret the deviations from ideality as a change in the standard deviation with time. This approach has shown a high accuracy in the fitting to tailing and fronting peaks. However, it has the drawback of the uncontrolled growth of the predicted signal outside the elution region, which departs from the experimental baseline. To solve this problem, the Parabolic-Lorentzian Modified Gaussian (PLMG) model was developed. This combines a parabola that describes the variance change in the peak region, and a Lor…

ChromatographyDegree (graph theory)Chemistrymedia_common.quotation_subjectGaussianParabolaCauchy distributionVariance (accounting)BiochemistrySignalAsymmetryStandard deviationAnalytical Chemistrysymbols.namesakesymbolsEnvironmental ChemistrySpectroscopymedia_commonAnalytica Chimica Acta
researchProduct

Prediction of peak shape as a function of retention in reversed-phase liquid chromatography

2004

Optimisation of the resolution of multicomponent samples in HPLC is usually carried out by changing the elution conditions and considering the variation in retention of the analytes, to which a standard peak shape is assigned. However, the change in peak shape with the composition of the mobile phase can ruin the optimisation process, yielding unexpected overlaps in the experimental chromatograms for the predicted optimum, especially for complex mixtures. The possibility of modelling peak shape, in addition to peak position, is therefore attractive. A simple modified-Gaussian model with a parabolic variance, which is a function of conventional experimental parameters: retention time (tR), p…

ChromatographyElutionChemistryOrganic ChemistryResolution (electron density)Analytical chemistryGeneral MedicineReversed-phase chromatographyFunction (mathematics)Models TheoreticalBiochemistryHigh-performance liquid chromatographyStandard deviationAnalytical ChemistryApproximation errorPhase (matter)Chromatography LiquidJournal of Chromatography A
researchProduct

Target analysis of primary aromatic amines combined with a comprehensive screening of migrating substances in kitchen utensils by liquid chromatograp…

2015

An analytical strategy including both the quantitative target analysis of 8 regulated primary aromatic amines (PAAs), as well as a comprehensive post-run target screening of 77 migrating substances, was developed for nylon utensils, using liquid chromatography-orbitrap-high resolution mass spectrometry (LC-HRMS) operating in full scan mode. The accurate mass data were acquired with a resolving power of 50,000 FWHM (scan speed, 2 Hz), and by alternating two acquisition events, ESI+ with and without fragmentation. The target method was validated after statistical optimization of the main ionization and fragmentation parameters. The quantitative method presented appropriate performance to be u…

ChromatographyPrimary (chemistry)Food contactChemistryRelative standard deviationAnalytical chemistryTarget analysisFood ContaminationOrbitrapCooking and Eating UtensilsAnalytical Chemistrylaw.inventionMassNylonsKitchen utensilslawTandem Mass SpectrometryAnalytical strategyHumansAminesOrganic ChemicalsChromatography LiquidTalanta
researchProduct

FIA-Chemiluminescence Determination of Acridine Yellow

2003

Abstract The direct determination of yellow acridine is performed by a FIA assembly on the basis of the oxidation of the acridine. The acridine solution is injected into a pure water stream. This solution merges with the oxidant solution (KMnO4 in sulfuric acid medium) and the resulting chemiluminescence allows the method to be applied over the range 0.01–100 mg L−1 of acridine with a correlation coefficient of 0.9997. The relative standard deviation (%) is 1.6 and the sample throughput 60 h−1. The influence of foreign substances is also tested. The new method is applied to the determination of yellow acridine in waste waters.

ChromatographyStereochemistryBiochemistry (medical)Clinical BiochemistryRelative standard deviationSulfuric acidWater streamBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganatechemistryAcridine yellowlawAcridineElectrochemistryQuantitative analysis (chemistry)SpectroscopyChemiluminescenceAnalytical Letters
researchProduct

Comparison of spectrophotometric and HPLC methods for determining sialic acid in infant formulas

2011

Abstract Two methods for determining sialic acid in infant formulas – spectrophotometry and HPLC with fluorescence detection – have been optimised and validated, the first one allows to determine total sialic acid while the second allows to differentiate the two main forms of sialic acid (N-acetylneuraminic acid (Neu5Ac) and N-glycolylneuraminic acid (Neu5Gc)). A common sample preparation procedure (hydrolysis and purification) for both methods has been proposed. The linearity (from 6 to 150 μg of total sialic acid in the assay for spectrophotometry, and from 12.5 to 250 ng and 1 to 5 ng of Neu5Ac and Neu5Gc, respectively, for HPLC) is adequate. The detection and quantification limits (0.29…

Chromatographymedicine.diagnostic_testRelative standard deviationGeneral MedicineHigh-performance liquid chromatographyFluorescenceAnalytical ChemistrySialic acidHydrolysischemistry.chemical_compoundInfant formulachemistrySpectrophotometrymedicineSample preparationFood ScienceFood Chemistry
researchProduct

Analysis of ventricular fibrillation signals using feature selection methods

2012

Feature selection methods in machine learning models are a powerful tool to knowledge extraction. In this work they are used to analyse the intrinsic modifications of cardiac response during ventricular fibrillation due to physical exercise. The data used are two sets of registers from isolated rabbit hearts: control (G1: without physical training), and trained (G2). Four parameters were extracted (dominant frequency, normalized energy, regularity index and number of occurrences). From them, 18 features were extracted. This work analyses the relevance of each feature to classify the records in G1 and G2 using Logistic Regression, Multilayer Perceptron and Extreme Learning Machine. Three fea…

Computer sciencebusiness.industryFeature extractionFeature selectionPattern recognitionRegression analysiscomputer.software_genreStandard deviationKnowledge extractionMultilayer perceptronData miningArtificial intelligencebusinessClassifier (UML)computerExtreme learning machine2012 3rd International Workshop on Cognitive Information Processing (CIP)
researchProduct

Observed and Simulated Variability of Droplet Spectral Dispersion in Convective Clouds Over the Amazon

2021

In this study, the variability of the spectral dispersion of droplet size distributions (DSDs) in convective clouds is investigated. Analyses are based on aircraft measurements of growing cumuli near the Amazon basin, and on numerical simulations of an idealized ice‐free cumulus. In cleaner clouds, the relative dispersion ϵ, defined as the ratio of the standard deviation to the mean value of the droplet diameter, is negatively correlated with the ratio of the cloud water content (qc) to the adiabatic liquid water content (qa), while no strong correlation between ϵ and qc/qa is seen in polluted clouds. Bin microphysics numerical simulations suggest that these contrasting behaviors are associ…

ConvectionAtmospheric ScienceAmazon rainforestaerosolcloudsSpectral dispersionMICROFÍSICA DE NUVENSAtmospheric sciencesdroplet spectumStandard deviationGeophysicsddc:551.5Space and Planetary ScienceLiquid water contentEarth and Planetary Sciences (miscellaneous)Environmental sciencedispersionAdiabatic processDroplet sizeWater contentPhysics::Atmospheric and Oceanic Physics
researchProduct

Experiments with an adaptive Bayesian restoration method

1989

Abstract This paper describes a Bayesian restoration method applied to two-dimensional measured images, whose detector response function is not completely known. The response function is assumed Gaussian with standard deviation depending on the estimate of the local density of the image. The convex hull of the K -nearest neighbours ( K NN) of each ‘on’ pixel is used to compute the local density. The method has been tested on ‘sparse’ images, with and without noise background.

Convex hullGaussianImage processingStandard deviationsymbols.namesakeArtificial IntelligenceBayesian restorationElectrical and Electronic EngineeringImage restorationK-nearest-neighbours algorithmMathematics1707PixelSettore INF/01 - Informaticabusiness.industryPattern recognitionsparse imageFunction (mathematics)Signal ProcessingsymbolsComputer Vision and Pattern RecognitionArtificial intelligenceDeconvolutionbusinessconvex hullSoftware
researchProduct