Search results for "stent"
showing 10 items of 1166 documents
Iliac-femoral stent-graft infection after hybrid procedure redo: Case report
2021
Introduction Stent-graft infection in peripheral arteries is rare and potentially dangerous. The use of hybrid procedures, in complicated patients previously treated, involves an increase of infective risk especially in no collaborative patients. Presentation of case We report a case of rare stent-graft infection in a patient treated for a Rutherford IV Multiple Peripheral Arterial Disease (MPAD) involving the right iliac-femoral axis with stenosis on deep femoral artery due to a previously stenting procedure for Superficial Femoral artery (SFA) stenosis. The first simultaneous hybrid intervention consisted of an endovascular iliac stent-graft placement and a surgical common femoral patch a…
Retrograde recanalization of an in-stent ostial chronically occluded right coronary artery
2010
We describe a case of a chronic proximal in-stent CTO extending up to the ostium of a right coronary artery where successful achievement of guidewire passage through the CTO was performed with a retrograde approach. Guidewire trapping into the right guiding catheter was performed thereafter and procedure was completed by retrograde balloon crossing and antegrade stenting. © 2009 Elsevier Ireland Ltd.
„Stent-in-Stent”
1993
Comparison of antiplatelet effects of aspirin, ticlopidine, or their combination after stent implantation.
1998
Background —This study was performed to analyze the influence of either aspirin, ticlopidine, or their combination on platelet activation and aggregation parameters after stent implantation. Methods and Results —Sixty-one patients with successful implantation of a single Palmaz-Schatz stent in a native coronary artery were randomly assigned to either group A (aspirin 300 mg/d+ticlopidine 2×250 mg/d), group B (ticlopidine 2×250 mg/d), or group C (aspirin 300 mg/d). Platelet activation was evaluated on days 1, 7, and 14 by flow cytometry measurement of expression of CD62p (p-selectin) and the binding of fibrinogen to the platelet surface glycoprotein IIb/IIIa receptor. Platelet aggregation w…
Systemic pulsatile pressure in type II endoleaks after stent grafting of experimental abdominal aortic aneurysms.
2003
Purpose: To investigate pressure and maximum rate of rise of systolic pressure (peak dP/dt) in completely excluded aneurysms and endoleaks to determine the hemodynamic impact of endoleaks. Methods: In mongrel dogs (n = 36) experimental aneurysms were created by insertion of a patch (portion of rectus abdominis muscle sheath) into the infrarenal aorta. In group I (n = 18), all aortic branches of the aneurysm were ligated and all aneurysms were completely excluded by stent grafts. Group II (n = 18) consisted of aneurysms with patent aortic side branches that represented sources of endoleaks. One week (n = 12), six weeks (n = 12), and six months (n = 12) after stent grafting, hemodynamic measu…
Three-Year Results of Hydrus Microstent with Phacoemulsification
2019
Abstract We report the 3-year IOP efficacy of the implantation of the Schlemm’s canal Hydrus® Microstent (Ivantis®) combined with phacoemulsification versus phacoemulsification alone
Comparison of Percutaneous Coronary Intervention (With Drug-Eluting Stents) Versus Coronary Artery Bypass Grafting in Women With Severe Narrowing of …
2014
Women typically present with coronary artery disease later than men with more unfavorable clinical and anatomic characteristics. It is unknown whether differences exist in women undergoing treatment for unprotected left main coronary artery (ULMCA) disease. Our aim was to evaluate long-term clinical outcomes in women treated with percutaneous coronary intervention (PCI) with drug-eluting stents versus coronary artery bypass grafting (CABG). All consecutive women from the Drug-Eluting stent for LefT main coronary Artery disease registry with ULMCA disease were analyzed. A propensity matching was performed to adjust for baseline differences. In total, 817 women were included: 489 (59.8%) unde…
Coronary stent implantation in acute vessel closure 48 hours after an unsatisfactory coronary angioplasty
1990
We report the implantation of a balloon-expandable stent in a patient with acute vessel closure in the state of evolving myocardial infarction following 48 hr after unsatisfactory coronary angioplasty. The stent was implanted after successful recanalization of an occluded left anterior descending artery, with repeated unsatisfactory results of balloon angioplasty. Adjunct thrombolytic therapy was contraindicated. No residual stenosis was documented in immediate control angiograms, or after 24 hr, 3 weeks, and 4 months.
Simultaneous cardiocerebral embolization in patients with atrial fibrillation
2020
Implant-specific follow-up imaging of treated intracranial aneurysms: TOF-MRA vs. metal artifact reduced intravenous flat panel computed tomography a…
2017
Aim To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. Methods The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n= 20; clipping: n= 15; coiling + stenting: n= 9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-ima…