Search results for "stent"

showing 10 items of 1166 documents

Combining Sirolimus-eluting Stents and External Irradiation in Cholesterol-fed Rabbits Increased Incomplete Stent Apposition and Decreased Re-endothe…

2009

Restenosis after the implantation of a drug-eluting stent or after vascular irradiation therapy shares similar physiopathological mechanisms. No experimental data are currently available on vascular wall behavior after external irradiation on arteries stented with sirolimus-eluting stents (SES). Ten New Zealand white rabbits received a 0.5% cholesterol-enriched chow for 1 month. Bilateral iliac artery stent implantation was then performed with an SES (Cypher; Cordis Corp). The animals were randomized into either an irradiated group (I, 2 Gy external x-ray irradiation, n = 5) or a control group (C, n = 5). The cholesterol-enriched chow was continued for 1 additional month after stent implant…

Malemedicine.medical_specialtyTime FactorsEndotheliummedicine.medical_treatmentUrologyCholesterol Dietarychemistry.chemical_compoundRestenosismedicineAnimalsSirolimusPharmacologyCholesterolbusiness.industryX-RaysStentDose-Response Relationship RadiationDrug-Eluting StentsIncomplete stent appositionequipment and suppliesmedicine.diseaseImmunohistochemistryPathophysiologySurgeryStenosisCholesterolmedicine.anatomical_structurechemistrySirolimusEndothelium VascularRabbitsTunica IntimaTunica MediaCardiology and Cardiovascular MedicinebusinessImmunosuppressive Agentsmedicine.drugJournal of Cardiovascular Pharmacology
researchProduct

Complete versus incomplete revascularization in patients with multivessel disease undergoing percutaneous coronary intervention with drug-eluting ste…

2008

Objectives: To investigate the long-term prognostic implications of complete versus incomplete revascularization in multivessel coronary artery disease (MVD) patients undergoing percutaneous coronary intervention (PCI) with drug-eluting stent (DES). Background: Coronary artery bypass grafting (CABG) in patients with MVD provides better outcomes when complete revascularization is achieved. There is a paucity of data on the outcomes of complete versus incomplete revascularization of MVD patients undergoing PCI, and currently there is no data available with DES. Methods: Patients with MVD undergoing PCI with DES (sirolimus- or paclitaxel-eluting stent) were included. Comparisons of long-term o…

Malemedicine.medical_specialtyTime FactorsPaclitaxelmedicine.medical_treatmentPopulationCoronary Artery DiseaseKaplan-Meier EstimateRevascularizationRisk AssessmentCoronary artery diseaseInternal medicinemedicineHumansRadiology Nuclear Medicine and imagingMyocardial infarctionRegistriesAngioplasty Balloon CoronaryeducationAgedProportional Hazards ModelsRetrospective StudiesSirolimuseducation.field_of_studyMultivessel diseasebusiness.industryStentPercutaneous coronary interventionCardiovascular AgentsDrug-Eluting StentsGeneral MedicineMiddle Agedmedicine.diseaseSurgeryRevascularization strategy.Treatment OutcomeDrug-eluting stentCardiovascular DiseasesConventional PCICardiologyFemaleDrug-eluting stentCardiology and Cardiovascular MedicinebusinessCatheterization and cardiovascular interventions : official journal of the Society for Cardiac AngiographyInterventions
researchProduct

The DETOUR procedure: no more need for conventional bypass surgery?

2018

Background Long segment occlusive disease in the superficial femoral artery remains a treatment challenge despite advances in open surgical and endovascular approaches. We report initial clinical results of an entirely new procedure to perform percutaneous femoro-popliteal bypass using the DETOUR System. First-in-human patients were performed in New Zealand from December 2013 to June 2014. After modifications to the technique and devices had significantly refined the procedure, the Detour I Trial commenced. Methods Review of initial results in the first five patients treated at a single site enrolled in IRB-approved, prospective clinical study using the DETOUR System. All patients signed in…

Malemedicine.medical_specialtyTime FactorsPercutaneousComputed Tomography AngiographyDeep veinmedicine.medical_treatmentFemoral veinConstriction PathologicFemoral artery030204 cardiovascular system & hematology030218 nuclear medicine & medical imagingBlood Vessel Prosthesis ImplantationPeripheral Arterial Disease03 medical and health sciences0302 clinical medicineRecurrenceBlood vessel prosthesismedicine.arterymedicineHumansProspective StudiesVascular PatencyAgedAged 80 and overbusiness.industryEndovascular ProceduresStentPhlebographyGeneral MedicineMiddle AgedLatviaPopliteal arteryBlood Vessel ProsthesisSurgeryFemoral ArteryTreatment Outcomemedicine.anatomical_structureBypass surgeryFemaleStentsSurgeryCardiology and Cardiovascular MedicinebusinessThe Journal of Cardiovascular Surgery
researchProduct

9-Month Clinical and Angiographic Outcomes of the COBRA Polyzene-F NanoCoated Coronary Stent System

2016

Abstract Objectives The aim of this study was to assess the safety and effectiveness of the COBRA Polyzene-F NanoCoated Coronary Stent System (CeloNova Biosciences, San Antonio, Texas) for the treatment of de novo coronary artery lesions. Background Polyzene-F–coated coronary stents have shown reduced thrombogenicity and inflammation in preclinical studies. Methods Patients with de novo coronary artery lesions meeting eligibility criteria were enrolled in a nonrandomized, prospective clinical trial. The primary endpoint was target vessel failure (TVF) (defined as a composite of cardiac death, myocardial infarction, or clinically driven target vessel revascularization) at 9 months. A pre-spe…

Malemedicine.medical_specialtyTime FactorsPolymersmedicine.medical_treatmentCoronary Artery Disease030204 cardiovascular system & hematologyCoronary AngiographyProsthesis DesignCoronary RestenosisCoronary artery disease03 medical and health sciencesOrganophosphorus Compounds0302 clinical medicineCoated Materials BiocompatibleCoronary thrombosisRestenosisPredictive Value of TestsRisk FactorsInternal medicineAngioplastyCoronary stentmedicineClinical endpointHumansProspective Studies030212 general & internal medicineMyocardial infarctionAngioplasty Balloon CoronaryAgedbusiness.industryCoronary ThrombosisStentMiddle Agedmedicine.diseaseCoronary VesselsSurgeryTreatment OutcomeCardiologyNanoparticlesFemaleStentsCardiology and Cardiovascular MedicinebusinessJACC: Cardiovascular Interventions
researchProduct

Bioresorbable polymer-coated thin strut sirolimus-eluting stent vs durable polymer-coated everolimus-eluting stent in daily clinical practice: Propen…

2018

Objectives We sought to determine the 1-year clinical follow-up in patients treated with the thin strut (71 μm) bioabsorbable polymer-coated sirolimus-eluting stent (BP-SES) vs durable coating everolimus eluting stent (DP-EES) in daily clinical routine. Background Presence of durable polymers may be associated with late/very late stent thrombosis occurrence and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. Methods Interventional Cardiology Network Registry is a prospective, multicenter, observational registry of 21,400 consecutive patients treated with PCI since 2010. We analyzed 4,670 patients treated …

Malemedicine.medical_specialtyTime FactorsPolymersmedicine.medical_treatmentCoronary Artery Disease030204 cardiovascular system & hematologyProsthesis DesignRisk Assessment03 medical and health sciencesPercutaneous Coronary Intervention0302 clinical medicineRisk FactorsAbsorbable ImplantsmedicineHumansRadiology Nuclear Medicine and imagingEverolimusRegistries030212 general & internal medicineMyocardial infarctionAngioplasty Balloon CoronaryPropensity ScoreAgedRetrospective StudiesSirolimusInterventional cardiologybusiness.industryStentPercutaneous coronary interventionCardiovascular AgentsDrug-Eluting StentsGeneral MedicineMiddle Agedmedicine.diseaseSurgeryTreatment OutcomeBioresorbable polymerSirolimusConventional PCIPropensity score matchingFemaleObservational studyPolandCardiology and Cardiovascular Medicinebusinessmedicine.drugCatheterization and Cardiovascular Interventions
researchProduct

Early outcomes with a single-sided access endovascular stent

2018

Abstract Objective The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. Methods Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events …

Malemedicine.medical_specialtyTime FactorsTime Factormedicine.medical_treatment030204 cardiovascular system & hematologyProsthesis DesignAortographySettore MED/22 - Chirurgia Vascolare03 medical and health sciencesAortic aneurysmBlood Vessel Prosthesis ImplantationPostoperative Complications0302 clinical medicineAneurysmBlood vessel prosthesismedicineStentHumansAged; Aortic Aneurysm Abdominal; Aortography; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Europe; Female; Humans; Male; Middle Aged; Postoperative Complications; Prospective Studies; Prosthesis Design; Time Factors; Tomography X-Ray Computed; Treatment Outcome; Blood Vessel Prosthesis; StentsProspective Studies030212 general & internal medicineStrokeAgedEndovascular Procedurebusiness.industryEndovascular ProceduresStentPerioperativeMiddle Agedmedicine.diseaseBlood Vessel ProsthesisSurgeryEuropeProspective StudieBlood Vessel ProsthesiTreatment OutcomeStentsFemaleSurgeryPostoperative ComplicationParaplegiabusinessTomography X-Ray ComputedCardiology and Cardiovascular MedicineAbdominal surgeryAortic Aneurysm AbdominalHuman
researchProduct

Second asymptomatic carotid surgery trial (ACST-2): a randomised comparison of carotid artery stenting versus carotid endarterectomy.

2021

Summary Background Among asymptomatic patients with severe carotid artery stenosis but no recent stroke or transient cerebral ischaemia, either carotid artery stenting (CAS) or carotid endarterectomy (CEA) can restore patency and reduce long-term stroke risks. However, from recent national registry data, each option causes about 1% procedural risk of disabling stroke or death. Comparison of their long-term protective effects requires large-scale randomised evidence. Methods ACST-2 is an international multicentre randomised trial of CAS versus CEA among asymptomatic patients with severe stenosis thought to require intervention, interpreted with all other relevant trials. Patients were eligib…

Malemedicine.medical_specialtyTime FactorsTime Factormedicine.medical_treatmentCarotid StenosiMEDLINECarotid endarterectomyRate ratioRisk AssessmentAsymptomaticlaw.inventionRandomized controlled triallawRisk Factorscarotid artery stenting (CAS); carotid endarterectomy (CEA)StentmedicineHumansCarotid StenosisStrokeEndarterectomyAgedEndarterectomy Carotidbusiness.industrycarotid arteryRisk FactorArticlesGeneral Medicinetrialmedicine.diseaseSettore MED/22 - CHIRURGIA VASCOLARESurgeryStrokeStenosisTreatment Outcomecarotid artery stenting (CAS)Settore MED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLAREFemaleStentsHuman medicinemedicine.symptomcarotid endarterectomy (CEA)businessHumanLancet (London, England)
researchProduct

Optical Coherence Tomography Versus Intravascular Ultrasound to Evaluate Coronary Artery Disease and Percutaneous Coronary Intervention

2013

ObjectivesWe compared intravascular ultrasound (IVUS) and 2 different generations of optical coherence tomography (OCT)—time-domain OCT (TD-OCT) and frequency-domain OCT (FD-OCT)—for the assessment of coronary disease and percutaneous coronary intervention (PCI) using stents.BackgroundOCT is a promising light-based intravascular imaging modality with higher resolution than IVUS. However, the paucity of data on OCT image quantification has limited its application in clinical practice.MethodsA total of 227 matched OCT and IVUS pull backs were studied. One hundred FD-OCT and IVUS pull backs in nonstented (n = 56) and stented (n = 44) vessels were compared. Additionally, 127 matched TD-OCT and …

Malemedicine.medical_specialtyTime Factorsgenetic structuresmedicine.medical_treatmentTreatment outcomeSeverity of Illness Indexintravascular ultrasoundCoronary RestenosisCoronary artery diseaseOptical coherence tomographyPredictive Value of TestsNeointimaIntravascular ultrasoundmedicineHumanscardiovascular diseasesUltrasonography InterventionalAgedCell ProliferationAnalysis of VarianceHyperplasiaoptical coherence tomographymedicine.diagnostic_testbusiness.industrypercutaneous coronary interventionCoronary StenosisPercutaneous coronary interventionMiddle Agedequipment and suppliesmedicine.diseaseCoronary Vesselseye diseasesTreatment Outcomesurgical procedures operativeLinear ModelsFemaleStentssense organsTomographyRadiologyUltrasonographybusinessCardiology and Cardiovascular MedicineTomography Optical CoherenceJACC: Cardiovascular Interventions
researchProduct

Initial Clinical Experience Using the Low-Profile Altura Endograft System With Double D-Shaped Proximal Stents for Endovascular Aneurysm Repair.

2018

Purpose: To report the initial clinical results of endovascular aneurysm repair (EVAR) using the low-profile (14-F) Altura Endograft System, which features a double “D-shaped” stent design with suprarenal fixation and modular iliac components that are deployed from distal to proximal. Methods: From 2011 to 2015, 90 patients (mean age 72.8±8.3 years; 79 men) with abdominal aortic aneurysm (AAA; mean diameter 53.8±5.7 mm) were treated at 10 clinical sites in 2 prospective, controlled clinical studies using the Altura endograft. Outcomes evaluated included mortality, major adverse events (MAEs: all-cause death, stroke, paraplegia, myocardial infarction, respiratory failure, bowel ischemia, an…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatment030204 cardiovascular system & hematologyProsthesis DesignEndovascular aneurysm repairRisk Assessment03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicinePostoperative ComplicationsRisk FactorsmedicineHumansRadiology Nuclear Medicine and imaging030212 general & internal medicineMyocardial infarctionAdverse effectStrokeAgedAged 80 and overbusiness.industryPatient SelectionEndovascular ProceduresMiddle Agedmedicine.diseaseThrombosisAbdominal aortic aneurysmSurgeryBlood Vessel ProsthesisProsthesis FailureTreatment OutcomeRespiratory failureSurgeryFemaleStentsCardiology and Cardiovascular MedicineParaplegiabusinessAortic Aneurysm AbdominalJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

CT Angiography at 24 Months Demonstrates Durability of EVAR With the Use of Chimney Grafts for Pararenal Aortic Pathologies

2013

PURPOSE: To present the 24-month radiological follow-up data for patients with pararenal aortic pathologies treated with chimney and periscope grafts during endovascular repair. METHODS: Between January 2008 and December 2011, 124 high-risk patients with complex pararenal aortic pathologies were treated using the chimney technique at 2 European vascular and cardiovascular centers with advanced experience of the described technique. In particular, 50 patients were treated at Site 1 and 74 at Site 2. Forty (32.2%) patients (32 men; mean age 79.2±4.9 years) completed computed tomographic angiography follow-up at 24 months postoperatively. RESULTS: The overall technical success was 100%, and th…

Malemedicine.medical_specialtyTime Factorsmedicine.medical_treatmentAortic Diseases610 Medicine & healthEndovascular aneurysm repair2705 Cardiology and Cardiovascular MedicineAortic aneurysmAneurysmmedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingAorta AbdominalEmbolizationSuperior mesenteric arteryAgedendovascular aneurysm repair chimney graft periscope graft pararenal aortic pathologies aortic aneurysm para-anastomotic aneurysm ruptured aneurysm stent-graft balloon-expandable stent-graft computed tomographic angiography endoleak renal arteries superior mesenteric artery sac shrinkage sac expansionmedicine.diagnostic_test10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular ProceduresAngiographyPerioperativemedicine.diseaseBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgerySurgeryCuffAngiographyFemaleStentsSurgeryRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesJournal of Endovascular Therapy
researchProduct