Search results for "strength"

showing 10 items of 2415 documents

Premolars restored with posts of different materials: fatigue analysis

2011

Previous works studied the effect of the material and the dimensions of the post on the biomechanical performance (fracture strength and stress distribution) of restored teeth, under static loads. The aim of this work was to study the effect of the post material (glass fibre and stainless steel) on restored teeth, which have the final crown, under dynamic conditions. The use of a biomechanical model, including a fatigue analysis from FEA, is presented as a powerful method to study the effect of the material of the intraradicular post. The inclusion of the fatigue analysis allows for a more realistic study that takes into account the dynamic nature of masticatory forces. At the same time, th…

Dental Stress AnalysisMaterials sciencemedicine.medical_treatmentGlass fiberInfluence of post materialMaterials testingCrown (dentistry)Bite ForceDental MaterialsTooth FracturesFlexural strengthMaterials TestingmedicineHumansImplant denturesBicuspidComposite materialGeneral DentistryFEAFatigueTooth NonvitalCrownsImplants dentalsRestored teethStress distributionStainless SteelFinite element methodDental Prosthesis DesignDental Stress AnalysisCeramics and CompositesBiomechanical modelGlassDental materials--FatiguePrefabricated intraradicular postsMaterials dentals--FatigaDental AlloysPost and Core Technique
researchProduct

Luting of ceramic crowns with a self-adhesive cement: Effect of contamination on marginal adaptation and fracture strength

2012

Objectives: This study evaluated the percentages of continuous margins (%CM) and fracture strength (FS) of crowns made out from blocs of leucite-reinforced ceramic (IPS Empress CAD) and luted with a representative self-adhesive cement (RelyX Unicem) under four contaminating agents: saliva, water, blood, a haemostatic solution containing aluminium chloride (pH= 0.8) and a control group with no contamination. Study Design: %CM at both tooth-cement (TC) and cement-crown (CC) interfaces were determined before and after a fatigue test consisting of 600’000 chewing loads and 1’500 temperature cycles changing from 5º C to 50º C. Load to fracture was recorded on fatigued specimens. Kruskal-Wallis t…

Dental Stress AnalysisSalivaAluminium chlorideDental CementsDentistryOdontologíaIn Vitro TechniquesDental porcelainFlexural strengthDental cementBiomaterials and Bioengineering in DentistryDentinmedicineHumansGeneral DentistryCementCrownsChemistrybusiness.industryContamination:CIENCIAS MÉDICAS [UNESCO]Dental PorcelainCiencias de la saludddc:617.6Resin Cementsmedicine.anatomical_structureOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgerybusinessmedicine.drugMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Fracture resistance after implantoplasty in three implant-abutment connection designs

2020

Background To assess the effect of implantoplasty and implant-abutment design on the fracture resistance and macroscopic morphology of narrow-diameter (3.5 mm) dental implants. Material and Methods Screw-shaped titanium dental implants (n = 48) were studied in vitro. Three groups (n = 16) were established, based on implant-abutment connection type: external hexagon, internal hexagon and conical. Eight implants from each group were subjected to an implantoplasty procedure; the remaining 8 implants served as controls. Implant wall thickness was recorded. All samples were subjected to a static strength test. Results The mean wall thickness reductions varied between 106.46 and 153.75 µm. The me…

Dental Stress AnalysisTitanium implantMaterials scienceCirurgia dentalchemistry.chemical_elementDental Abutments03 medical and health sciences0302 clinical medicineFlexural strengthDental AbutmentsMaterials TestingGeneral DentistryEndosseous dental implantsDental ImplantsTitaniumOrthodonticsCrownsResearchConnection (principal bundle)030206 dentistry:CIENCIAS MÉDICAS [UNESCO]OtorhinolaryngologychemistryDental surgeryUNESCO::CIENCIAS MÉDICASFracture (geology)SurgeryImplants dentals intraossisImplantImplantologyImplant abutmentTitanium
researchProduct

Influence of material and diameter of pre-fabricated posts on maxillary central incisors restored with crown.

2009

Summary  Numerous research works have studied the effect of post-design parameters on the mechanical behaviour of restored teeth without reaching any clear conclusions. Previous works by the authors ascertained the effect of material and post-dimensions for non-crowned restored teeth. The aim of this work was to study the effect of post-material and diameter for crowned teeth. First, an experimental fracture strength test was performed on eighteen extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (nine with glass fibre posts and nine with stainless steel posts). Several post-diameters were used. The final crown restoration was carried ou…

Dental Stress Analysisinfluence of post-materialMaterials sciencemedicine.medical_treatmentGlass fiberFinite Element AnalysisDentistryCrown (dentistry)Dental Materialsstomatognathic systemFlexural strengthstress distributionMaterials TestingmedicineMaxillaHumansMaxillary central incisorDental Restoration PermanentGeneral Dentistryinfluence of post-diameterbusiness.industrybiomechanical performanceStress distributionIncisorstomatognathic diseasesDental Prosthesis DesignFracture (geology)pre-fabricated intra-radicular postsinfluence of crownFinite element techniqueGlassbusinessPost and Core TechniqueJournal of oral rehabilitation
researchProduct

Marketing Communications of Latvian Social Enterprises from a Consumer Perspective

2020

The purpose of this study is twofold - to contribute to the further understanding of social enterprises’ marketing by providing a consumers’ perspective on the content that social enterprises generate in order for them be to be able to better understand their strengths and weaknesses and to establish a reference point with regards the current situation to be able to compare and measure improvement in with regards social enterprise marketing in the future and, if needed, provide fact-based evidence to assist social enterprises in their call for support from public authorities. Among tasks of research are 1) analysis of recent scientific publications associate with social enterprises, their c…

Descriptive statisticsmedia_common.quotation_subjectQuantitative researchSocial entrepreneurshipSubsidyBusinessMarketingMarketing researchWelfareStrengths and weaknessesDrawbackmedia_commonEuropean Integration Studies
researchProduct

Mapping and holistic design of natural hydraulic lime mortars

2020

Supplementary data to this article can be found online at https://doi.org/10.1016/j.cemconres.2020.106167.

Design0211 other engineering and technologies02 engineering and technologyengineering.materialCompatibilityFlexural strengthEngenharia e Tecnologia::Engenharia CivilConsistency (statistics)021105 building & constructionGeneral Materials ScienceGeotechnical engineeringMathematicsScience & TechnologyAggregate (composite)Artificial neural networksMonument protectionHydraulic limeExperimental dataBuilding and Construction021001 nanoscience & nanotechnologyCompressive strengthCompatibility (mechanics):Engenharia Civil [Engenharia e Tecnologia]engineeringNatural hydraulic limeMortar0210 nano-technologyMortar characteristicsCement and Concrete Research
researchProduct

Ionic liquid-based single-drop microextraction followed by liquid chromatography-ultraviolet spectrophotometry detection to determine typical UV filt…

2009

Abstract A user-friendly and inexpensive ionic liquid-based single-drop microextraction (IL-SDME) procedure has been developed to preconcentrate trace amounts of six typical UV filters extensively used in cosmetic products (i.e., 2-hydroxy-4-methoxybenzophenone, isoamyl 4-methoxycinnamate, 3-(4′-methylbenzylidene)camphor, 2-ethylhexyl 2-cyano-3,3-diphenylacrylate, 2-ethylhexyl 4-dimethylaminobenzoate and 2-ethylhexyl 4-methoxycinnamate) from surface water samples prior to analysis by liquid chromatography-ultraviolet spectrophotometry detection (LC-UV). A two-stage multivariate optimization approach was developed by means of a Plackett–Burman design for screening and selecting the significa…

Detection limitAnalyteChromatographyCentral composite designmedicine.diagnostic_testAnalytical chemistryRepeatabilityAnalytical Chemistrychemistry.chemical_compoundchemistryIonic strengthSpectrophotometryIonic liquidmedicineSample preparationTalanta
researchProduct

Determination of UV filters in both soluble and particulate fractions of seawaters by dispersive liquid–liquid microextraction followed by gas chroma…

2014

An analytical method to determine the total content (i.e., not only in the soluble fraction but also in the particulate one) of eight commonly used UV filters in seawater samples is presented for the first time. Dispersive liquid-liquid microextraction (DLLME) is used as microextraction technique to pre-concentrate the target analytes before their determination by gas chromatography-mass spectrometry (GC-MS). In order to release the UV filters from the suspended particles an ultrasound treatment is performed before DLLME. The ultrasound treatment time was studied in order to achieve a quantitative lixiviation of the target analytes. The type and volume of both disperser and extraction solve…

Detection limitAnalyteChromatographyLiquid Phase MicroextractionUltraviolet RaysChemistryOsmolar ConcentrationExtraction (chemistry)Analytical chemistryRepeatabilityHydrogen-Ion ConcentrationMass spectrometryBiochemistryGas Chromatography-Mass SpectrometryAnalytical ChemistrySolventIonic strengthSolventsEnvironmental ChemistrySeawaterGas chromatography–mass spectrometrySpectroscopyAnalytica Chimica Acta
researchProduct

Sensitive determination of free benzophenone-3 in human urine samples based on an ionic liquid as extractant phase in single-drop microextraction pri…

2007

Abstract Benzophenone-3 (BZ3), one of the compounds most commonly used as UV filter in cosmetic products, can be absorbed through the skin into the human body, since it can be found at trace levels in urine from users of cosmetic products that contain BZ3. Moreover, different undesirable effects have been attributed to this compound. Thus, sensitive analytical methods to monitor urinary excretion of this compound should be developed. This paper presents a selective and sensitive methodology for BZ3 determination at ultratrace levels in human urine samples. The methodology is based on a novel microextraction technique, known as single-drop microextraction (SDME). An ionic liquid (IL) has bee…

Detection limitChromatographyCentral composite designOrganic ChemistryAnalytical chemistryTemperatureIonic LiquidsGeneral MedicineBiochemistryHigh-performance liquid chromatographyChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundBenzophenoneschemistryIonic strengthLiquid–liquid extractionStandard additionIonic liquidHumansSample preparationChromatography LiquidJournal of chromatography. A
researchProduct

DETECTION LIMITS FOR NATURAL CIRCULAR-DICHROISM OF CHIRAL COMPLEXES IN THE X-RAY RANGE

1993

Whereas both Magnetic Circular Dichroism and Faraday Rotation studies have been successfully carried out at the K-, L- and M-absorption edges of metal atoms in ferromagnetic systems, Natural optical activity of chiral complexes has not yet been detected quite unambiguously in the X-ray range. We review a number of theoretical arguments which confirm that the optical asymmetry factor gσ should be very small in the X-ray range for unoriented powdered samples, especially at the K-absorption edges. This stimulating challenge prompted us to start an intensive programme of measurements aimed at detecting natural circular dichroism in both the soft and “firm” X-ray ranges. Although some of our ex…

Detection limitCircular dichroismRange (particle radiation)Magnetic circular dichroismChemistrymedia_common.quotation_subjectXAFSSOFT-X-RAY SPECTROSCOPYGeneral EngineeringAnalytical chemistryX-rayGeneral Physics and AstronomyOPTICAL-ACTIVITYAsymmetryMolecular physicssymbols.namesakeROTATORY STRENGTHFerromagnetismNATURAL CDFaraday effectsymbolsABSORPTIONOPTICAL ASYMMETRYTRANSITION-METAL COMPLEXESmedia_commonJapanese journal of applied physics part 1-Regular papers short notes & review papers
researchProduct