Search results for "structures"
showing 10 items of 4815 documents
Opto-mechanical artificial eye with accommodative ability.
2015
The purpose of this study was to describe the design and characterization of a new opto-mechanical artificial eye (OMAE) with accommodative ability. The OMAE design is based on a second-pass configuration where a small source of light is used at the artificial retina plane. A lens whose focal length can be changed electronically was used to add the accommodation capability. The changes in the OMAE's aberrations with the lens focal length, which effectively changes the accommodative state of the OMAE, were measured with a commercial aberrometer. Changes in power and aberrations with room temperature were also measured. The OMAE's higher-order aberrations (HOAs) were similar to the ones of th…
Modulation transfer function in refractive-diffractive multifocal intraocular lenses in vitro
2007
Purpose: The optical quality of two types of multifocal, hybrid refractive-diffractive, intraocular lenses (IOL) is analyzed in vitro. Following the EN-ISO international standard, the IOLs’ modulation transfer functions (MTF) are determined for both distance and near vision. The behaviour of these curves when the pupil size varies is studied. Methods: The IOLs analyzed were: AcrySoft ResTor SN60D3 (Alcon) and Tecnis ZM900 (AMO). The MTF was calculated from the cross line-spread function recorded with the OPAL Vector System (Image Science Ltd. Oxford) by using fast Fourier transform techniques. The artificial eye model used simulates in vivo conditions of the anterior chamber including an ar…
Contrast sensitivity perimetry tests along the cardinal directions in color space: Correlation with the properties of the neural mechanisms mediating…
2014
It is well-known the advantages of measuring chromatic and achromatic contrast sensitivity for detecting pathologies. But these measurements are rarely used in clinical practice, due the complexity of the measurements and the examinator specialization. In fact, there is not a complete characterization of the response of the visual pathways to achromatic and chromatic spatio-temporal frequency stimuli. We have designed a new experimental device that facilitates these measurements and allow us to characterize the visual response in healthy patients. In this paper, we evaluated the responses of the visual pathways in healthy patients.
The Internuclear Ophthalmoplegias
1993
Internuclear ophthalmoplegia (INO), which is caused by an ipsilateral medial longitudinal fasciculus (MLF) lesion, is characterized by adduction paresis of lateral gaze, usually with spared convergence [1–4]. In the opposite eye, abduction nystagmus and hypermetric abduction saccades are the main clinical and electro-oculographic abnormalities [1, 5, 6]. The origin of both is still debated. Abduction nystagmus has been explained by (a) an additional horizontal gaze paresis [7]; (b) vergence mechanisms aimed at alignment of the visual axes [8]; (c) interruption of descending excitatory projections from oculomotor nucleus internuclear neurons to contralateral abducens nucleus motoneurons [9];…
Multispectral analysis and cone signal modelling of pseudoisochromatic test plates
2013
The aim of the study is to determine the consistency of the desired colour reproduction of the stimuli using calibrated printing technology available to anyone (EpsonStylus Pro 7800 printer was). 24 colour vision assessment plates created in the University of Latvia were analysed right after their fabrication on august 2012 and after intense use for 7 months (colour vision screening on 700 people). Multispectral imagery results indicate that the alignment of the samples after seven months of use has maintained on the CIExy confusion lines of deutan deficiency type, but the shift towards achromatic area in the diagram indicate decrease in the total colour difference (ΔE*ab) of test backgroun…
The role of neuroinflammation in the pathogenesis of glaucoma neurodegeneration
2020
The chapter is a review enclosed in the volume "Glaucoma: A pancitopatia of the retina and beyond." No cure exists for glaucoma. Knowledge on the molecular and cellular alterations underlying glaucoma neurodegeneration (GL-ND) includes innovative and path-breaking research on neuroinflammation and neuroprotection. A series of events involving immune response (IR), oxidative stress and gene expression are occurring during the glaucoma course. Uveitic glaucoma (UG) is a prevalent acute/chronic complication, in the setting of chronic anterior chamber inflammation. Managing the disease requires a team approach to guarantee better results for eyes and vision. Advances in biomedicine/biotechnolog…
2015
The combination of local orientation collinearity and spatial frequency contrast in contour integration was studied in two experiments using a 2AFC contour detection and discrimination task. Target contours were defined by local orientation collinearity, spatial frequency contrast between contour and background elements, or both cues. Experiments differed in the source of spatial frequency contrast by manipulating the spatial frequency of either contour or background elements. Cue summation gains, defined as the performance benefit of double cue conditions over single cue conditions, were evaluated and tested against the predictions derived from probability summation and linear summation. S…
<title>Modified crossed-cylinder aberroscope</title>
2001
We report a technique to estimate eye aberrations, based mainly on the subjective crossed-cylinder method. In order to obtain accurate coordinates of cross sections of the aberration distorted grid image on the retinal plane, needed in subjective methods, fusion of two images is used. The image seen by the eye under investigation is fused by the patient with a similar grid generated and reshaped in the appropriate way on the computer screen. The computer simulated image is viewed either by the second eye (in order to avoid eye rivalry and suppression processes, that are typical for such conditions, stimuli for both eyes are discontinuous and are displayed sequentially with a frequency of 50…
Automatic Conjunctival Provocation Test Using Hough Transform of Extended Canny Edge Maps
2013
Computer-aided diagnosis is developed for assessment of allergic rhinitis/rhinoconjunctivitis measuring the relative redness of sclera under application of allergen solution. The patient’s eye images are taken from commercial digital camera. The iris is robustly localized using a gradient-based Hough circle transform. From the center of the pupil, the region of interest within the sclera is extracted using geometric anatomybased a-priori information. The red color pixels are extracted thresholding in the hue, saturation and value color space. Then, redness is measured by taking mean of saturation projected into zero hue. Evaluation is performed with 92 images taken from 13 subjects, 8 respo…
Anatomy of the visual system
2004
This brief systemic overview presents the anatomic details of the orbit with respect to imaging modalities CT and MR. The structures of the four orbital compartments, intrakonal and extrakonal space, globe and optic nerve are demonstrated in detail on different CT and MR views (axial, coronal, in soft tissue and bone window, T1-weighted, T2-weighted) with corresponding diagrams. The intracranial visual pathway is explained in detail with emphasis to the striate cortex and extrastriate visual association cortex, presented with diagrams and high-resolution MR.