Search results for "techno"
showing 10 items of 31274 documents
pKa at Quartz/Electrolyte Interfaces.
2016
Acidity of silanol sites at the crystalline quartz/aqueous electrolyte (NaCl, NaI, KCl) interfaces are calculated from ab initio molecular dynamics simulations. pKa’s are found to follow a combination of the cationic and anionic Hofmeister series in the order pKa(neat solution) < pKa(NaCl) < pKa(NaI) < pKa(KCl), in agreement with experimental measurements. Rationalization of this ranking is achieved in terms of the microscopic local solvation of the protonated silanols and their conjugated bases, the silanolates SiO–. The change in the pKa is the result of both water destructuring by alkali halides, as well as of the specific cation/SiO– interaction, depending on the electrolyte. M…
Inelastic neutron scattering study of proton dynamics in Ca(OH)2 at 20 K
1995
Abstract Inelastic neutron scattering (INS) spectra of Ca(OH) 2 at 20 K are presented from 30 to 4000 cm −1 for a powder sample, from 30 to 12000 cm −1 for an oriented single-crystal. INS band splitting due to the lattice density-of-states is observed. Polarization effects reveal the orientation of atomic displacements for each mode and a new band assignment scheme is proposed. For the single-crystal, the v OH mode and overtones are observed. This oscillator shows only moderate anharmonicity. Spectrum simulation reveals that INS spectral intensities are not consistent with simple normal coordinates and harmonic force-fields for Ca(OH) 2 entities. A new dynamical model is proposed, including…
Neutron imaging and tomography: Applications in food science
2018
International audience; Neutron imaging and tomography allow observing the structure of large objects (from few to hundred centimeters) at a resolution around 100 μm. This non-destructive method is based on the detection of the transmission of a neutron beam through an object in 2D (imaging) or 3D after rotating the sample (tomography). The components of the object attenuate the neutron beam differently, depending on their composition, and produce accurate pictures of objects which give information about their structure. Neutron imaging has been used for quality control purposes in industries (aircraft, motor engineering...), but also find application from materials sciences (fuel cells, li…
Comparaison expérimentale de techniques de caractérisation en intensité et phase d'impulsions optiques ultracourtes
2006
Nous comparons experimentalement les resultats de la caracterisation en intensite et en phase d'impulsions optiques ultracourtes obtenus par differentes techniques employant un montage auto/inter-correlateur en intensite et un analyseur de spectre. Nous employons pour ces tests une impulsion en limite de Fourier, une impulsion affectee par l'auto-modulation de phase et une impulsion similariton.
A Study of Milk Particles Size Variation with pH Change using Dynamic Light Scattering
2019
A very simple experimental setup for a Dynamic Light Scattering measurement was used to measure the average size of the milk proteins in aqueous suspensions at 20 °C. The PH of the suspensions was adjusted using Calcium lactate, in its most common form of pentahydrate C6H10CaO6•5H2O. The mean size variation of the suspended particles in time has been monitored and reveals a fast increase over a time interval of less than ten of seconds.
Polarization-driven spin precession of mesospheric sodium atoms: publisher's note.
2018
This publisher's note corrects an error in the author listing of Opt. Lett.43, 5825 (2018)OPLEDP0146-959210.1364/OL.43.005825.
Estimation des incertitudes de mesure sur bras polyarticulé portable par méthode de Monte Carlo
2013
International audience; Les bras polyarticulés portables ont progressivement évolué et sont de plus en plus utilisés dans l’industrie. Cependant, à l’heure actuelle, la traçabilité de ces dispositifs est difficile à effectuer et les incertitudes de mesures relatives à l’utilisation de ces appareils ne sont pas quantifiées. Le travail mené consiste à déterminer les incertitudes de mesures associées à la quantification, par un bras polyarticulé portable, des caractéristiques géométriques et dimensionnelles d’une pièce mécanique. Les travaux visant à élaborer un modèle d’incertitude de mesure, sont basés sur la méthode de Monte Carlo du supplément 1 du Guide pour l'expression de l'incertitude …
Effective characterization of the phase and intensity profiles of asymmetrically distorted light pulses in optical fiber systems
2009
International audience; We address the problem of characterization of light pulses that propagate in long-haul high-bit-rate optical communication systems under strongly perturbed conditions. We show that the conventional technique for characterization of the phase and intensity profile of such pulses becomes qualitatively inconsistent when the pulse's profile is asymmetrically distorted with respect to its center of mass. We resolve these inconsistencies by partially reformulating the conventional technique by means of appropriate pulse parameters, which we call upgraded parameters, that allow a fair characterization of the intensity and phase of all types of light pulses, including those …
Supercontinuum generation in titanium dioxide waveguides
2019
International audience; Optical supercontinua are a fundamental topic that has stimulated a tremendous practical interest since the early works of Alfano et al. in the 70’s in bulk components. Photonic crystal fibers have then brought some remarkable potentialities in tailoring the dispersive properties of a waveguide while maintaining a high level of confinement over significant propagation distances. The next breakthrough is to further reduce the footprint of the nonlinear component and to achieve the generation of optical supercontinuum on a photonic chip. To reach this aim, several platforms have been successfully investigated such as silicon, silicon germanium, silicon nitride, chalcog…
Active components for integrated plasmonic circuits
2009
International audience; We present a comprehensive study of highly efficient and compact passive and active components for integrated plasmonic circuit based on dielectric-loaded surface plasmon polariton waveguides.