Search results for "telemonitoring"

showing 6 items of 6 documents

Hands-feet wireless devices: Test-retest reliability and discriminant validity of motor measures in Parkinson's disease telemonitoring

2022

Background Telemonitoring, a branch of telemedicine, involves the use of technological tools to remotely detect clinical data and evaluate patients. Telemonitoring of patients with Parkinson's disease (PD) should be performed using reliable and discriminant motor measures. Furthermore, the method of data collection and transmission, and the type of subjects suitable for telemonitoring must be well defined. Objective To analyze differences in patients with PD and healthy controls (HC) with the wearable inertial device SensHands-SensFeet (SH-SF), adopting a standardized acquisition mode, to verify if motor measures provided by SH-SF have a high discriminating capacity and high intraclass corr…

motor function assessmentFootParkinson's diseasesubclinical motor abnormalitieswearable sensorsReproducibility of ResultstelemonitoringParkinson DiseaseGeneral MedicineWearable Electronic DevicesNeurologyHumansbiomechanical parametersSettore MED/26 - NeurologiaNeurology (clinical)telemedicineGait
researchProduct

Pathways for urology patients during the COVID-19 pandemic

2020

The public health emergency caused by the Coronavirus Disease 2019 (COVID-19) pandemic has resulted in a significant reallocation of health resources with a consequent reorganization of the clinical activities also in several urological centers. A panel of Italian urologists has agreed on a set of recommendations on pathways of pre-, intra- and post-operative care for urological patients undergoing urgent procedures or non-deferrable oncological interventions during the COVID-19 pandemic. Simplification of the diagnostic and staging pathway has to be prioritized in order to reduce hospital visits and consequently the risk of contagion. In absence of strict uniform regulations that impose th…

Clinical practice guidelineTelemonitoringPandemicClinical pathwayUrologyCoronaviruCOVID-19
researchProduct

Vascular Health Assessment of The Hypertensive Patients (VASOTENS) Registry: Study Protocol of an International, Web-Based Telemonitoring Registry fo…

2016

Background: Hypertension guidelines recommend ambulatory blood pressure (ABP), central aortic pressure (CAP), and pulse wave velocity (PWV) as parameters for estimating blood pressure (BP) control and vascular impairment. Recent advances in technology have enabled devices to combine non-invasive estimation of these parameters over the 24-hour ABP monitoring. However, currently there is limited evidence on the usefulness of such an approach for routine hypertension management. Objective: We recently launched an investigator-initiated, international, multicenter, observational, prospective study, the Vascular health Assessment Of The Hypertensive patients (VASOTENS) Registry, aimed at (1) eva…

medicine.medical_specialtyTelemedicineAmbulatory blood pressureSettore MED/09 - Medicina Internacentral aortic pressurehypertensionpulse wave velocity030204 cardiovascular system & hematologyaugmentation index03 medical and health sciences0302 clinical medicinearterial stiffneProtocolMedicine030212 general & internal medicineProspective cohort studyPulse wave velocitySettore MED/14 - Nefrologiablood pressure telemonitoringbusiness.industryblood pressure telemonitoring; arterial stiffness; pulse wave velocity; augmentation index; central aortic pressure; hypertensionGeneral Medicinemedicine.diseaseSurgeryBlood pressurearterial stiffnessEmergency medicinearterial stiffness; augmentation index; blood pressure telemonitoring; central aortic pressure; hypertension; pulse wave velocityAortic pressureArterial stiffnessObservational studybusinessJMIR Research Protocols
researchProduct

Telemonitoring in chronic pain management using smartphone apps: a randomized controlled trial comparing usual assessment against app-based monitorin…

2020

Background. The usefulness of mHealth in helping to target face-to-face interventions for chronic pain more effectively remains unclear. In the present study, we aim to test whether the Pain Monitor mobile phone application (app) is well accepted by clinicians, and can help improve existent medical treatments for patients with chronic musculoskeletal pain. Regarding this last goal, we compared three treatment conditions, namely usual treatment, usual treatment with an app without alarms and usual treatment with an app with alarms. All treatments lasted one month. The three treatments were compared for all outcomes, i.e., pain severity and interference, fatigue, depressed mood, anxiety and a…

medicine.medical_specialtyHealth Toxicology and Mutagenesismedia_common.quotation_subjectPsychological interventionlcsh:MedicineAngerArticlelaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled triallawmental disordersmedicineHumansPain Management030212 general & internal medicinemHealthSalut mentalmedia_commonClinical eventsbusiness.industrylcsh:RPublic Health Environmental and Occupational HealthChronic painecological momentary assessmenttelemonitoringmedicine.diseaseMobile Applicationssmartphone appClinical AlarmsSmartphone apprandomized controlled trialPhysical therapyAnxietySmartphonemedicine.symptomChronic Painbusinesschronic pain030217 neurology & neurosurgery
researchProduct

Ambulatory blood pressure and arterial stiffness web-based telemonitoring in patients at cardiovascular risk. First results of the VASOTENS (Vascular…

2019

The VASOTENS Registry is an international telehealth-based repository of 24-hour ambulatory blood pressure monitorings (ABPM) obtained through an oscillometric upper-arm BP monitor allowing combined estimation of some vascular biomarkers. The present paper reports the results obtained in 1200 participants according to different categories of CV risk. Individual readings were averaged for each recording and 24-hour mean of brachial and aortic systolic (SBP) and diastolic blood pressure (DBP), pulse wave velocity (PWV), and augmentation index (AIx) obtained. Peripheral and central BP, PWV and AIx values were increased in older participants (SBP only) and in case of hypertension (SBP and DBP).…

Malecentral aortic pressureNon-Randomized Controlled Trials as TopicEndocrinology Diabetes and Metabolism030204 cardiovascular system & hematologyaugmentation index0302 clinical medicinearterial stiffness; augmentation index; blood pressure; blood pressure telemonitoring; central aortic pressure; hypertension; pulse wave velocity; vascular biomarkersDiastoleRisk Factorsarterial stiffneProspective StudiesRegistries030212 general & internal medicinePulse wave velocityAortaMetabolic Syndromeblood pressureBlood Pressure Monitoring AmbulatoryMiddle AgedTelemedicinearterial stiffnessCardiovascular DiseasesAmbulatorycardiovascular systemCardiologyFemaleCardiology and Cardiovascular MedicineInternet-Based Interventioncirculatory and respiratory physiologyAdultmedicine.medical_specialtyAmbulatory blood pressurehypertensionSystolepulse wave velocityPulse Wave AnalysisVascular health03 medical and health sciencesVascular StiffnessOscillometryInternal medicineInternal MedicinemedicineHumansArterial PressureIn patientcardiovascular diseasesAgedblood pressure telemonitoringbusiness.industryvascular biomarkersmedicine.diseasevascular biomarkerCross-Sectional StudiesBlood pressureCase-Control StudiesArterial stiffnessMetabolic syndromebusiness
researchProduct

Variable association of 24-h peripheral and central hemodynamics and stiffness with hypertension-mediated organ damage: the VASOTENS Registry.

2020

Objective In this analysis of the telehealth-based Vascular health ASsessment Of The hypertENSive patients Registry, we checked how 24-h central and peripheral hemodynamics compare with hypertension-mediated organ damage (HMOD). Methods In 646 hypertensive patients (mean age 52 ± 16 years, 54% males, 65% treated) we obtained ambulatory brachial and central SBP and pulse pressure (PP), SBP, and PP variability, pulse wave velocity and augmentation index with a validated cuff-based technology. HMOD was defined by an increased left ventricular mass index (cardiac damage, evaluated in 482 patients), an increased intima-media thickness (vascular damage, n = 368), or a decreased estimated glomerul…

AdultMalemedicine.medical_specialtySettore MED/09 - Medicina InternaPhysiologyarterial stiffness augmentation index blood pressure blood pressure telemonitoring central arterial pressure hypertension pulse wave velocity vascular biomarkersRenal functionHemodynamicsBlood Pressure030204 cardiovascular system & hematologyPulse Wave AnalysisKidneyCarotid Intima-Media Thickness03 medical and health sciences0302 clinical medicineInternal medicineInternal MedicinemedicineHumans030212 general & internal medicineRegistriesPulse wave velocityAgedSettore MED/14 - Nefrologiabusiness.industryHemodynamicsBlood Pressure DeterminationOdds ratioBlood Pressure Monitoring AmbulatoryMiddle Agedmedicine.diseasePulse pressureBlood pressureAmbulatoryHypertensionCardiologyArterial stiffnessFemaleCardiology and Cardiovascular MedicinebusinessGlomerular Filtration RateJournal of hypertension
researchProduct