Search results for "tensile test"

showing 4 items of 54 documents

Understanding the Effects of Crosslinking and Reinforcement Agents on the Performance and Durability of Biopolymer Films for Cultural Heritage Protec…

2021

In the last two decades, the naturally occurring polysaccharides, such as chitosan and pectin, have gained great attention having potential applications in different sectors, from biomedical to new generation packaging. Currently, the chitosan and pectic have been proposed as suitable materials also for the formulation of films and coatings for cultural heritage protection, as well as packaging films. Therefore, the formulation of biopolymer films, considering only naturally occurring polymers and additives, is a current challenging trend. This work reports on the formulation of chitosan (CS), pectin (PC), and chitosan:pectin (CS:PC) films, also containing natural crosslinking and reinforce…

food.ingredientMaterials sciencePectinMechanical behaviorsPharmaceutical Science02 engineering and technologyengineering.material010402 general chemistry01 natural sciencesHalloysiteArticleDurabilityAnalytical ChemistryChitosanContact angleCitric acidchemistry.chemical_compoundQD241-441foodDrug DiscoveryPhysical and Theoretical ChemistryTensile testingchemistry.chemical_classificationChitosanOptical propertiesHalloysite nanotubesOrganic ChemistryPolymer021001 nanoscience & nanotechnologyPectin0104 chemical scienceschemistryChemical engineeringChemistry (miscellaneous)engineeringMolecular MedicineWettingBiopolymer0210 nano-technologyMolecules
researchProduct

Effects of hydrogen-charging on the properties of S235JR steel

2017

The paper presents the test results of the S235JR steel susceptibility to damage under the influence of hydrogen. The test of mechanical properties was performed on the basis of a static stretch test of non-hydrogenated samples and after cathodic polarization. Electrochemical measurements for the assessment of corrosion resistance of non-hydrogenated and hydrogenated steels were carried out using open circuit potential measurement and registering of potentiodynamic polarization curves in a three-electrode measuring system. Hydrogenation was carried out for between 3 and 24 hours in a solution of 0.1 N sulfuric acid (VI) with the addition of 2 mg/dm 3 of arsenic oxide (III) at an electric cu…

lcsh:GE1-350Materials scienceHydrogenScanning electron microscopeMetallurgychemistry.chemical_elementSulfuric acid02 engineering and technologyElectrochemistry020501 mining & metallurgyCorrosionchemistry.chemical_compound020303 mechanical engineering & transports0205 materials engineering0203 mechanical engineeringchemistryArsenic oxideComposite materialSaturation (chemistry)lcsh:Environmental sciencesTensile testingE3S Web of Conferences
researchProduct

Influence of sutures configuration on the strength of tendon-patch joints for rotator cuff tears treatment

2019

Abstract Purpose Massive rotator cuff tears are common in the aging population. The incidence of failed rotator cuff repairs is still quite high, especially in the treatment of full-thickness tears or revision repairs. In this context, natural and synthetic meshes can be used as augmentation scaffolds or as devices to close the gap between a retracted tendon and the bone. The purpose of this work is to evaluate the ultimate tensile strength of different tendon-patch joints in order to consider their use in the treatment of massive cuff tears. Materials and methods Porcine tendons and a synthetic low-density polypropylene mesh have been used. A preliminary study on the tensile strength of te…

musculoskeletal diseasesSwineRotator cuff tearBiocompatible MaterialsContext (language use)Synthetic patchRotator Cuff InjuriesTensile strengthTendonsRotator Cuff03 medical and health sciences0302 clinical medicineExperimental testUltimate tensile strengthAnimalsMedicineRotator cuffRange of Motion ArticularSettore ING-IND/15 - Disegno E Metodi Dell'Ingegneria IndustrialeReverse engineeringJoint (geology)General Environmental ScienceTensile testing030222 orthopedicsSuturesExperimental test; Reverse engineering; Rotator cuff tear; Synthetic patch; Tensile strengthbusiness.industrySuture Techniques030208 emergency & critical care medicinePlastic Surgery Proceduresmusculoskeletal systemTendonmedicine.anatomical_structureModels AnimalCuffGeneral Earth and Planetary SciencesbusinessRange of motionBiomedical engineeringInjury
researchProduct

Fibre fragment distribution in a single-fibre composite tension test

2001

Abstract Single fibre fragmentation tests are performed for brittle fibres with Weibull strength distribution and different surface treatments. The fragmentation process is modelled and closed-form expressions for break spacing distribution are obtained. The model accounts for the effect of finite fibre length on the initial fragmentation as well as for break interaction on the advanced fragmentation stage. It is assumed that the exclusion zone due to fibre–matrix interface failure and stress recovery in the fibre is linearly dependent on the applied load. This assumption is validated experimentally. The derived theoretical average fragment length dependence on applied load is used to deter…

single fibre compositeanalytical modellingMaterials scienceMechanical EngineeringGlass fiberComposite numberThermosetting polymerEpoxySingle fibreIndustrial and Manufacturing EngineeringfibresBrittlenessMechanics of Materialsfragmentationvisual_artCeramics and Compositesvisual_art.visual_art_mediumComposite materialTensile testingWeibull distributionComposites Part B: Engineering
researchProduct