Search results for "testi"
showing 10 items of 4607 documents
Cutting efficiency of heat-treated nickel-titanium single-file systems at different incidence angles.
2020
Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s. Cutting efficiency was determined by measuring the block weight loss with an analytical balance and measuring the length of the block surface cut using a digital calliper. Data were statistically analysed (two-way ANOVA, Bonferroni t-test) with the significance level set at P < 0.05. There was no difference for REC among the tested angles. REB had no statistical differenc…
Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization
2010
Aim: The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. Study Design: A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted human mandibular first molars. The procedure was repeated to prepare 2 to 8 canals. The following irrigation solutions were used: group 1, RaCe files with 2.5% NaOCl; group 2, RaCe files with normal saline; group 3, Mtwo files with 2.5% NaOCl; and group 4, Mtwo files with normal saline in the manner desc…
Influence of bruxism on survival of porcelain laminate veneers
2013
Objectives: This study aims to determine whether bruxism and the use of occlusal splints affect the survival of porcelain laminate veneers in patients treated with this technique. Material and Methods: Restorations were made in 70 patients, including 30 patients with some type of parafunc - tional habit. A total of 323 veneers were placed, 170 in patients with bruxism activity, and the remaining 153 in patients without it. A clinical examination determined the presence or absence of ceramic failure (cracks, frac - tures and debonding) of the restorations; these incidents were analyzed for association with bruxism and the use of splints. Results: Analysis of the ceramic failures showed that …
Determination of polymerization shrinkage stress by means of a photoelastic investigation
2002
This study examined the polymerization stress of different established composite resins (Tetric Ceram, Vivadent; EsthetX, Surefil, Dentsply/DeTrey; Clearfil AP-X, Clearfil Photo Posterior, Kuraray; Prodigy Condensable, sds Kerr; Filtek P 60, 3M ESPE; Solitaire 2, Heraeus-Kulzer) by means of a photo-elastic investigation and investigated six new, experimental composite resins, which have been claimed to exhibit less polymerization shrinkage (InTen-S, Vivadent; K 112, K 051, Dentsply/DeTrey; Compox, Pluto, Hermes 3M ESPE).Cylindrical cavities (phi 5 mm) in Araldit B epoxide resin plates (40 x 40 x 3 mm3) were pretreated with the Rocatec system to ensure bonding of the composite resin. Ten com…
Mechanical resistance of zirconium implant abutments: A review of the literature
2010
The increase of aesthetic demands, together with the successful outcome of current implants, has renewed interest in the search for new materials with enough mechanical properties and better aesthetic qualities than the materials customarily used in implanto-prosthetic rehabilitation. Among these materials, zirconium has been used in different types of implants, including prosthetic abutments. The aim of the present review is to analyse current scientific evidence supporting the use of this material for the above mentioned purposes. We carried out the review of the literature published in the last ten years (2000 through 2010) of in vitro trials of dynamic and static loading of zirconium ab…
Influence of prefabricated post material on restored teeth: fracture strength and stress distribution.
2006
This work studied how prefabricated intraradicular post material affects the mechanical performance of restored teeth. The effect of using two different materials (glass fiber and stainless steel) with significantly different elastic moduli was studied.A combined theoretical and experimental method was used: first, an experimental fracture strength test was performed on 60 extracted human maxillary central incisors. The teeth were decoronated, treated endodontically and restored, 30 with glass fiber posts and 30 with stainless steel posts. The data were recorded and the results compared using an ANOVA test. Then, the finite element technique was used to develop a model of the restored tooth…
Comparative fracture behavior of monolithic and veneered zirconia posterior fixed dental prostheses
2017
The purpose of this study was to evaluate and to compare the fracture load and the fracture pattern of monolithic and veneered zirconia posterior fixed dental prostheses (FDPs). Twenty standardized steel dies were prepared to receive posterior 3-unit FDPs. Specimens were randomly divided into 2 groups (n=10): (1) Lava Zirconia, and (2) Lava Plus. All FDPs were cemented using glass ionomer cement and subjected to thermal and mechanical cycling at 5-55ºC with a 30-s dwell time for 120,000 masticatory cycles. All specimens were subjected to a three-point bending test until fracture. Data were statistically analyzed using Student's t test, paired t-test and Weibull statistics (α=0.05). No diffe…
Effect of Thermomechanical and Static Loading on the Load to Fracture of Metal‐Ceramic, Monolithic and Veneered Zirconia Posterior Fixed Partial Dent…
2018
PURPOSE To evaluate the influence of static (not preloaded) and thermomechanical loading on the load to fracture of metal-ceramic, monolithic and veneered zirconia computer-aided design/computer-aided manufacturing (CAD/CAM) posterior fixed partial dentures (FPDs). MATERIALS AND METHODS One hundred standardized specimens with 2 abutments screwed onto a platform were prepared from stainless steel to receive a posterior 3-unit FPD with an intermediate pontic. Specimens were randomly divided into 5 groups (n = 20): Metal-ceramic (control group), Lava Zirconia system, Vita In-Ceram YZ, IPS e.max ZirCAD, and Lava Plus. Half of the specimens of each group (n = 10) underwent no preloading, and the…
Disinclusion of unerupted teeth by mean of self-ligating brackets: Effect of blood contamination on shear bond strength
2012
Objectives: The aim of this study was to assess the effect of blood contamination on the shear bond strength and failure site of three different orthodontic self-ligating brackets. Study Design: 240 bovine permanent mandibular incisors were randomly divided into 12 groups of 20 specimens each. Orthodontic self-ligating brackets were tested under four different enamel surface conditions: a) dry, b) blood contamination before priming, c) blood contamination after priming, d) blood contamination before and after priming. Brackets were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statis…
Influence of prefabricated post dimensions on restored maxillary central incisors
2007
summary The aim of this study was to test the following hypothesis: biomechanical performance (fracture strength and stress distribution) of restored teeth is less sensitive to post diameter and post length when using glass fibre posts than when using stainless steel posts. First, an experimental fracture strength test was performed on 80 extracted human maxillary central incisors. Teeth were decoronated, treated endodontically and restored (40 with glass fibre posts and 40 with stainless steel posts), and the length and diameter of the posts varied uniformly. Failure loads were recorded and results were compared using an ancova analysis. Secondly, the finite element technique was used to …