Search results for "thesis"

showing 10 items of 4193 documents

Radiologische Veränderungen nach Implantation zweier unterschiedlicher zementfreier Hüftschaftsysteme

1997

PURPOSE: Of the study was to evaluate radiological alterations of the femoral bone after implantation of two different prostheses. METHODS: 81 patients with 87 hips underwent total hip arthroplasty by using the Zweymuller-stem fixating in the medullary canal, and 175 patients with 182 ABG-stems with a proximally fixating, anatomical design were followed up clinically and radiologically. RESULTS: Adaptive bone remodelling in Zweymuller-stems showed in some patients thickening of the cortex of the femur and proximal bone-stock loss; reactive lines were seen in the proximal areas surrounding the prosthesis. Radiographs of patients with ABG-stems showed these lines in the distal, smooth part of…

medicine.medical_specialtyMedullary cavitybusiness.industrymedicine.medical_treatmentStress shieldingProsthesisSurgeryBone remodelingmedicine.anatomical_structureOrthopedic surgeryMedicineUpper limbRadiology Nuclear Medicine and imagingFemurImplantbusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Effect of oral glutathione on hepatic glutathione levels in rats and mice

1989

Administration of oral glutathione (GSH) increases hepatic GSH levels in fasted rats, in mice treated with GSH depletors such as diethyl maleate and in mice treated with high doses of paracetamol. An increase in hepatic GSH levels after administration of oral GSH does not occur in animals treated with buthionine sulphoximine, an inhibitor of GSH synthesis. Administration of oral GSH leads to an increase in the concentration of l-cysteine, a precursor of GSH, in portal blood plasma. Oral administration of l-methionine produced a significant decrease of hepatic ATP in fasted rats, but not in fed rats. Administration ofN−acetylcysteine or GSH did not affect the hepatic ATP levels. The results …

medicine.medical_specialtyNecrosisRatónMedicine (miscellaneous)Micechemistry.chemical_compoundAdenosine TriphosphateMethionineBiosynthesisOral administrationInternal medicineHepatic glutathionemedicineAnimalsCysteineAcetaminophenchemistry.chemical_classificationNutrition and DieteticsChemistryMaleatesRats Inbred StrainsFastingGlutathioneGlutathioneAcetylcysteineRatsAmino acidEndocrinologyLiverMechanism of actionmedicine.symptomBritish Journal of Nutrition
researchProduct

Neo-nervegenesis in 3D dynamic responsive implant for inguinal hernia repair. Qualitative study.

2020

Abstract Background Prosthetic repair of inguinal hernias is one of the most performed surgical procedures. Nevertheless, high rates of complications affect the surgical treatment. Implant fixation, poor-quality tissue ingrowth and mesh shrinkage seem to be involved in postoperative complications, discomfort and chronic pain following inguinal hernia repair. To address these issues a multilamellar shaped 3D dynamic responsive prosthesis has been developed. This new implant, positioned fixation-free to obliterate the hernia opening, thanks its inherent dynamic compliance during inguinal movements, has demonstrated to induce an enhanced biological response. The ingrowth of newly formed muscle…

medicine.medical_specialtyNeo-nervegenesimedicine.medical_treatmentConnective tissueArtificial LimbsHernia InguinalGroinProsthesisProsthesis Implantation03 medical and health sciences0302 clinical medicinePostoperative ComplicationsProstheseBiopsymedicineHumansHerniaTissue scaffoldsHerniorrhaphyQualitative ResearchGroinmedicine.diagnostic_testbusiness.industryInguinal herniaNerveGeneral MedicineSurgical Meshmedicine.diseaseHernia repairSurgerySettore MED/18 - Chirurgia GeneraleInguinal herniamedicine.anatomical_structure030220 oncology & carcinogenesisPrinting Three-DimensionalTissue regeneration030211 gastroenterology & hepatologySurgeryImplantbusinessInternational journal of surgery (London, England)
researchProduct

Endovascular Treatment of Spontaneous and Isolated Infrarenal Acute Aortic Syndrome with Unibody Aortic Stent-Grafts

2020

Abstract Introduction Spontaneous acute aortic syndrome (IAAS) is rarely localized in the infrarenal aorta. The endovascular approach is preferred over conventional open surgery with fewer complications. However, dedicated endovascular devices for IAAS treatment are unavailable. The aim was to report a large single-center experience using unibody stent-grafts to address IAAS. Methods From April 2016 to March 2019, a retrospective analysis of patients presenting spontaneous and isolated IAAS was performed. Patients addressed with the unibody stent-graft (AFX endovascular AAA system; Endologix Inc., Irvine, CA) were included in the study. Indications to IAAS treatment were persistent symptoms…

medicine.medical_specialtyOriginal Scientific Report030204 cardiovascular system & hematologyProsthesis DesignSettore MED/22 - Chirurgia VascolareInfrarenal acute aortic syndromeunibody stent-graftBlood Vessel Prosthesis Implantation03 medical and health sciencesAortic aneurysm0302 clinical medicineintramural hematoma.Blood vessel prosthesismedicine.arterymedicineHumansaortic dissection penetrating aortic ulcercardiovascular diseasesAorta Abdominal030212 general & internal medicineRetrospective StudiesAcute aortic syndromebusiness.industryEndovascular ProceduresAbdominal aortaVascular surgerymedicine.diseaseBlood Vessel ProsthesisSurgeryStenosissurgical procedures operativeTreatment OutcomeCardiothoracic surgeryendovascularStentsSurgerybusinessAortic Aneurysm AbdominalAbdominal surgeryWorld Journal of Surgery
researchProduct

Ergebnisse zementfreier Endoprothesen bei der nichttraumatischen Hüftkopfnekrose

2001

AIM OF THE STUDY The results from 56 patients with osteonecrosis of the femoral head who underwent 66 uncemented total hip replacements were analyzed and compared with current reports in the literature on cemented endoprosthesis. METHODS In the retrospective study in 30 of those cases the Zweymuller and in 25 cases the HA-coated ABG prosthesis were used. In addition the results of 11 patients with a polyethylene Endler cup in combination with a Zweymuller stem are presented. The mean age at surgery was 48 years, the mean follow-up was 5.9 years. Clinical examination, registration of the Merle d'Aubigne score and a radiological examination were performed. RESULTS The clinical results did not…

medicine.medical_specialtyOsteolysismedicine.diagnostic_testbusiness.industrymedicine.medical_treatmentRadiographyRetrospective cohort studyPhysical examinationAvascular necrosismedicine.diseaseProsthesisSurgeryFemoral headmedicine.anatomical_structureOrthopedic surgerymedicineOrthopedics and Sports MedicineSurgerybusinessZeitschrift für Orthopädie und ihre Grenzgebiete
researchProduct

Acetabulumfrakturen im Alter

2002

Acetabular fractures in elderly patients are rare injuries, but their incidence is increasing. Poor bone quality due to osteoporosis and an increased operative risk due to concomitant disease are factors complicating surgical therapy. Literature does not provide generally accepted treatment protocols. In a 4-year period, 27 patients who were 65 years or older and who had an acute displaced fracture of the acetabulum were admitted to our department. Four minimally displaced and stable fractures were managed conservatively. Internal fixation was performed in 16 cases. According to the Merle d'Aubigne score, in 15 out of 18 surviving patients excellent or good results were found. Treatment str…

medicine.medical_specialtyOsteosynthesisBone diseasebusiness.industrymedicine.medical_treatmentOsteoporosismedicine.diseaseSurgeryFemoral headmedicine.anatomical_structureFracture fixationBone plateEmergency MedicinemedicineInternal fixationOrthopedics and Sports MedicineSurgerybusinessReduction (orthopedic surgery)Der Unfallchirurg
researchProduct

Callus distraction of the femur and tibia. Experience with the Monofixator - indications for reosteosynthesis

1998

In a 4-year period, 18 patients underwent callus distraction of the femur or tibia with the use of a unilateral external fixator. Twelve patients had post-traumatic bone loss resulting from complex lower-limb fractures. The bony defect was located in the tibia in 11 cases and in the femur in one case. All patients had major associated soft-tissue lesions. The length of the bony defect averaged 6.25 cm. Eight fractures were infected at the beginning of treatment. Six other patients underwent callus distraction for reasons of limb shortening. Five femora and one tibia were lengthened. The average increase in length was 6.5 cm. There were no fixator-related complications during distraction. Th…

medicine.medical_specialtyOsteosynthesisbusiness.industrymedicine.medical_treatmentSurgerylaw.inventionIntramedullary rodExternal fixationlawDistractionOrthopedic surgeryEmergency MedicinemedicineDistraction osteogenesisOrthopedics and Sports MedicineSurgeryFemurTibiabusinessDer Unfallchirurg
researchProduct

Ergebnisse nach primärer ungebohrter Tibianagelung von Unterschenkelfrakturen mit schwerem offenem oder geschlossenem Weichteilschaden

1996

Primary stabilization was performed in 72 tibial fractures with sever open (n = 37) or closed (n = 35) soft tissue injury using unreamed interlocking nails. In 60 (83%) cases the fractures healed without additional procedures. There were 2 cases of osteitis, but both these fractures healed after removal of the nail or after reamed nailing. In 9 patients with delayed union reamed nailing (n = 8) or bone grafting (n = 1) led to healing. In 1 patient with hypertrophic pseudarthrosis, union was achieved after substitution of a reamed nail for the anreamed nail. The infection rate was similar to that observed with external fixation. More secondary procedures, such as bone grafting or a change of…

medicine.medical_specialtyOsteosynthesisintegumentary systembusiness.industrymedicine.medical_treatmentDentistryBone graftingmedicine.diseaseSurgerylaw.inventionIntramedullary rodPseudarthrosisFixation (surgical)External fixationlawSoft tissue injuryFracture fixationEmergency MedicinemedicineOrthopedics and Sports MedicineSurgeryskin and connective tissue diseasesbusinessDer Unfallchirurg
researchProduct

Jugular pacing lead extraction with laser sheath: a case report.

2010

Over the past 20 years, the number of patients with pacemakers (PM) or implantable cardioverter defibrillators has risen markedly; consequently, an increasing number of lead-removal procedures have become necessary. A 64-year-old woman presenting with an infected device pocket and positive bacterial cultures ( Staphylococcus aureus ) was admitted to our department for lead removal; in 1991, she underwent VVI PM implantation for atrioventricular II degree Mobitz 1 block, and a unipolar lead was introduced via the left jugular vein. The procedure was performed in our Electrophysiology Lab with a cardiac surgeon on standby, using an excimer laser system emitting the energy at the tip of a flex…

medicine.medical_specialtyPacemaker ArtificialProsthesis-Related Infectionslaw.inventionlawPhysiology (medical)Jugular veinlead extracion laser sheatMedicineHumansLead (electronics)Device RemovalEndocarditisbusiness.industryLasersCardiac Pacing ArtificialMiddle AgedStaphylococcal InfectionsLaserSettore MED/11 - Malattie Dell'Apparato CardiovascolareSurgeryCardiothoracic surgeryFluoroscopyFemaleJugular VeinsCardiology and Cardiovascular MedicinebusinessLead extractionEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
researchProduct

Drug eluting and bare metal stents in people with and without diabetes: Collaborative network meta-analysis

2008

Objective To compare the effectiveness and safety of three types of stents (sirolimus eluting, paclitaxel eluting, and bare metal) in people with and without diabetes mellitus. Design Collaborative network meta-analysis. Data sources Electronic databases (Medline, Embase, the Cochrane Central Register of Controlled Trials), relevant websites, reference lists, conference abstracts, reviews, book chapters, and proceedings of advisory panels for the US Food and Drug Administration. Manufacturers and trialists provided additional data. Review methods Network meta-analysis with a mixed treatment comparison method to combine direct within trial comparisons between stents with indirect evidence fr…

medicine.medical_specialtyPaclitaxelmedicine.medical_treatment030204 cardiovascular system & hematologyCoronary Restenosis03 medical and health scienceschemistry.chemical_compound0302 clinical medicineBlood vessel prosthesisInternal medicinemedicineHumans030212 general & internal medicinecardiovascular diseasesGeneral Environmental ScienceRandomized Controlled Trials as TopicSirolimusbusiness.industryResearchHazard ratioGeneral EngineeringDrug-Eluting StentsGeneral Medicineequipment and supplies3. Good healthSurgeryBlood Vessel ProsthesisProsthesis FailureClinical trialsurgical procedures operativePaclitaxelchemistryDrug-eluting stentMeta-analysisSirolimusGeneral Earth and Planetary SciencesPlatelet aggregation inhibitorStentsbusinessDiabetic AngiopathiesPlatelet Aggregation Inhibitorsmedicine.drug
researchProduct