Search results for "tibia"
showing 10 items of 212 documents
Vertical osteoconductivity and early bone formation of titanium-zirconium and titanium implants in a subperiosteal rabbit animal model.
2013
Objectives The aim of this pilot study was to evaluate the vertical osteoconductive and osteointegrative dynamics around titanium–zirconium (TiZr) implants compared to titanium (Ti) implants. Materials and methods In a split-leg design, 12 TiZr-SLActive and 12 Ti-SLActive implants were inserted 3 mm above bone level in the proximal tibia of 12 rabbits. Full periosteal flaps were repositioned to cover the site. Specimens were obtained after 10, 20 and 30 days (each n = 4 per group). Histomorphometric measurements included percentage of linear bone fill (PLF; %), new marginal vertical bone height (VBH; mm) and vertical bone-to-implant contact (vBIC; %). Statistical analysis was performed with…
Assessment of conduit artery vasomotion using photoplethysmography
2013
Vasomotion is a spontaneous oscillation of vascular tone. The phenomenon has been observed in small arterioles and capillaries as well as in the large conduit arteries. The layer of smooth muscle cells that surrounds a blood vessel can spontaneously and periodically change its tension and thereby the arterial wall stiffness also changes. As the understanding of the phenomenon is still rather obscure, researchers would benefit from a low-cost and reliable investigation technique such as photoplethysmography (PPG). PPG is an optical blood pulsation measurement technique that can offer substantial information about the arterial stiffness. The aims of this pilot study were to evaluate the usefu…
Advanced microscopy analysis of the micro-nanoscale architecture of human menisci
2019
AbstractThe complex inhomogeneous architecture of the human meniscal tissue at the micro and nano scale in the absence of artefacts introduced by sample treatments has not yet been fully revealed. The knowledge of the internal structure organization is essential to understand the mechanical functionality of the meniscus and its relationship with the tissue’s complex structure. In this work, we investigated human meniscal tissue structure using up-to-date non-invasive imaging techniques, based on multiphoton fluorescence and quantitative second harmonic generation microscopy complemented with Environmental Scanning Electron Microscopy measurements. Observations on 50 meniscal samples extract…
Influence of the use of autogenous bone particles to close the access window after maxillary sinus floor augmentation: an experimental study in rabbi…
2020
Abstract Aim To study the influence on the healing of the placement of particulate autogenous bone in the antrostomy and in the subjacent region after maxillary sinus elevation. Material and methods Sixteen New Zealand rabbits were undergone to bilateral maxillary sinus floor augmentation with 4 × 4 mm antrostomy dimension. The sinus mucosa was elevated, and the space obtained was filled with xenograft. In the test site (treated sites), autogenous bone was harvested from the tibia and was placed either in the antrostomy and the subjacent region while the control site was left untreated. Antrostomy was covered bilaterally with collagen membranes. Animals were euthanized after 1 and 8 weeks o…
Pathogenesis of circulatory reactions triggered by nervous reflexes during the implantation of bone cements.
1983
Circulatory and respiratory reactions during the implantation of joint endoprostheses have been observed for years. The components of the bone cements used for anchoring (methyl methacrylate monomer) or the outpour of bone marrow substances from the affected bone marrow cavity are thought to be chiefly responsible for these effects. However, our previous investigations demonstrated unambiguously that reactions of this type can be attributed to direct nervous-reflex mechanisms triggered by the pressure rise in the medullary canal, and that, in addition, bone marrow embolism plays a part in serious circulatory incidents. The investigations on which the present paper is based have confirmed th…
Neurilemoma of the tibial nerve in the popliteal fossa A case report
1993
We report a case of a 61 year old man who had a history of 4 years right leg pain. Clinical and radiological examination and MRI revealed a soft tissue mass in the popliteal fossa. A neurilemoma of the tibial nerve was confirmed after removal of the tumor and histological examination. To our knowledge this is the first case of a neurilemoma located in the tibial nerve reported in the literature.
Endometrial carcinoma with tibial bone metastasis: a case report and literature review.
2018
Endometrial cancer is the most common female genital malignancy and the seventh most common cause of death from cancer in women in Western countries. The median age of occurrence is 63 years, while...
Customizable Patient-Specific Cutting Guide for High Tibial Osteotomy
2019
Abstract The paper is an interdisciplinary medical and engineering approach that aims to optimize the accuracy of the High Tibial Osteotomy surgical intervention. The axial deviations of the human inferior limb are presented in the first part of the paper. Without altering the shape of the bones, these deviations cause the wear of the knee’s articular cartilage by gonarthrosis. One of the most common and effective treatment modalities for eliminating axial deviations is High Tibial Osteotomy. Because the surgical procedure involves 3D spatial bone cutting, the accuracy of the procedure and thus the success of the operation and the recovery of the patient is dependent on the execution of the…
Experimental modular stand used for studies of the High Tibial Osteotomy
2017
The optimization of the surgery strategies for the correction of the axial deviations of the human lower member presents a great importance both for the affected patients and for surgeons. This article seeks to develop a modular stand used mainly for experimental study of the High Tibial Osteotomy (HTO). In the article it is also shown the relation between the axial deviations of the human leg and their corrections using HTO. The modular devices were designed, executed and used in the experimental research.