Search results for "tomate"
showing 10 items of 261 documents
Diagnosing fatigue in gait patterns by support vector machines and self-organizing maps
2009
The aim of the study was to train and test support vector machines (SVM) and self-organizing maps (SOM) to correctly classify gait patterns before, during and after complete leg exhaustion by isokinetic leg exercises. Ground reaction forces were derived for 18 gait cycles on 9 adult participants. Immediately before the trials 7-12, participants were required to completely exhaust their calves with the aid of additional weights (44.4±8.8kg). Data were analyzed using: (a) the time courses directly and (b) only the deviations from each individual's calculated average gait pattern. On an inter-individual level the person recognition of the gait patterns was 100% realizable. Fatigue recognition …
Diagnostic accuracy of a fully automated multiplex celiac disease antibody panel for serum and plasma.
2019
Abstract Background An automated multiplex platform using capillary blood can promote greater throughput and more comprehensive studies in celiac disease (CD). Diagnostic accuracy should be improved using likelihood ratios for the post-test probability of ruling-in disease. Methods The Ig_plex™ Celiac Disease Panel on the sqidlite™ automated platform measured IgA and IgG antibodies to tTG and DGP in n = 224 CD serum or plasma samples. Diagnostic accuracy metrics were applied to the combined multiplex test results for several CD populations and compared to conventional single antibody ELISA tests. Results With multiple positive antibody results, the post-test probability for ruling-in untrea…
Effect of Kernels Used for the Reconstruction of MDCT Datasets on the Semi-Automated Segmentation and Volumetry of Liver Lesions
2014
Purpose: To evaluate the effect of different reconstruction kernels on the semi-automated segmentation of liver lesions in MDCT. Materials and Methods: A total 62 liver lesions were measured by three independent radiologists with the semi-automated segmentation software Oncology-Prototype (Fraunhofer MEVIS, Siemens Healthcare, Germany) using MDCT datasets (3-mm slice thickness, 2-mm increment) reconstructed with standard, soft and detailed kernels (Philips B, A and D). To ensure objective measurements, only lesions with satisfactory initial segmentation were included, and manual correction was not used. The effective diameter and volume were recorded for each lesion. Segmentation in the sof…
Optimal Response to Cardiac Arrest study: Defibrillation waveform effects
2001
Abstract Introduction: Advances in early defibrillation access, key to the “Chain of Survival”, will depend on innovations in defibrillation waveforms, because of their impact on device size and weight. This study compared standard monophasic waveform automatic external defibrillators (AEDs) to an innovative biphasic waveform AED. Material and methods: Impedance-compensated biphasic truncated exponential (ICBTE) and either monophasic truncated exponential (MTE) or monophasic damped sine (MDS) AEDs were prospectively, randomly assigned by date in four emergency medical services. The study design compared ICBTE with MTE and MDS combined. This subset analysis distinguishes between the two clas…
Comparison of DMEK and DSAEK in Eyes With Endothelial Decompensation After Previous Penetrating Keratoplasty.
2021
PURPOSE Posterior lamellar keratoplasty is increasingly applied in patients with endothelial decompensation after penetrating keratoplasty (PK). The aim of this study was to compare the results of Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK) after PK. METHODS In this retrospective study, clinical data of 30 patients who received DMEK (n = 19) or DSAEK (n = 11) for endothelial decompensation after PK were evaluated. All lamellar keratoplasties were performed at the Department of Ophthalmology at University Hospital Mainz, Germany. Primary end point included best-corrected visual acuity, and secondary end points included e…
Diagnosis and Classification of 17 Diseases from 1404 Subjects via Pattern Analysis of Exhaled Molecules.
2016
We report on an artificially intelligent nanoarray based on molecularly modified gold nanoparticles and a random network of single-walled carbon nanotubes for noninvasive diagnosis and classification of a number of diseases from exhaled breath. The performance of this artificially intelligent nanoarray was clinically assessed on breath samples collected from 1404 subjects having one of 17 different disease conditions included in the study or having no evidence of any disease (healthy controls). Blind experiments showed that 86% accuracy could be achieved with the artificially intelligent nanoarray, allowing both detection and discrimination between the different disease conditions examined.…
Recognition of Root Canal Orifices in Video Sequences as a Future Support System During Endodontic Treatment
2009
Abstract Introduction The objective of this study was to show the practical application of computer-aided techniques for detecting root canal orifices through the access cavity using a video camera mounted on a microscope. Methods A minimum distance classification image recognition algorithm was tested in an in vitro study to assess the possibilities of computer-aided recognition of root canal orifices. A Motic DM143 digital stereo microscope (Motic Germany GmbH, Wetzlar, Germany) was used because it includes a video camera that can be connected via USB1.1 to any computer. Results The newly developed software is capable of communicating with a video camera and can automatically detect the r…
Relevance of new recommendations on routine antenatal prevention of rhesus immunization: an appraisal based on a retrospective analysis of all cases …
2008
Abstract Objective To assess the potential impact of new guidelines recommending routine antenatal prophylaxis at 28 weeks of pregnancy on incidence, consequences and cost of rhesus immunization. Study design All rhesus immunizations of 224,500 ongoing pregnancies in two neighbouring administrative areas in France between 2000 and 2006 were enrolled in this retrospective study. To determine the aetiology of immunization and to specify when sensitization occurred, we searched sensitizing events between the last negative and the first positive red-cell antibody test results. Perinatal consequences and costing were also analyzed. Results From 138 rhesus negative women bearing anti-D antibodies…
Blue-yellow deficiencies in young moderate smokers.
2021
Purpose To evaluate whether tobacco affects color vision in young moderate smokers. Methods Chromatic mechanisms of 13 moderate smokers (10–20 cigarettes/day and at least 5 years smoking) and 17 non-smokers in the 18–35 age range were assessed with the Farnsworth-Munsell 100-hue (FM100h) test and short wavelength automated perimetry (SWAP). Results FM100h Total Error Scores (TES) were higher for smokers, and although differences were not significant (p = 0.14), a linear model with principal component analysis was able to explain 95% of the variance in TES and red-green partial error scores, though not in blue-yellow partial error scores (p = 0.07), using the number of years as smokers and t…
A fully automated system for the evaluation of masseter silent periods.
1997
Exteroceptive suppression of masseter muscle activity, 'masseter inhibitory reflex', comprises one or 2 silent periods (SP1 and SP2) interrupting the voluntary activation. The main problem when evaluating exteroceptive suppression is the lack of an objective and precise measure for the onset and end of the silent period which so far has not been overcome by various automated systems. We describe a new fully automated system for determining the onset and end of the masseter silent period. The decision approach is essentially based upon deterministic properties of median filters which are used to partition the local variances of the EMG traces into constant segments and edges between them. Th…