Search results for "tomography"
showing 10 items of 2332 documents
High rate of cardiac thrombus diagnosed by adding cardiac imaging in acute stroke computed tomography protocol
2020
Background Detection of left atrial appendage thrombus (LAAt) in acute stroke patients can be improved by cardiac computed tomography using prospective electrocardiogram-gated volume acquisition, which was added to the acute stroke computed tomography protocol in our institution in 2018. Aims To evaluate the factors and clinical management associated with LAAt in patients with acute ischemic stroke. Methods We retrospectively included 324 consecutive patients with ischemic stroke from November 2018 to October 2019. Clinical data and post-stroke management were compared in LAAt and no-LAAt patients. Results Thirty-five patients (10.8%; 95%CI 7.4–14.2) had LAAt and 289 had no-LAAt. LAAt patie…
Diagnostic of craniofacial asymmetry : literature review
2009
Facial asymmetry is a common feature in many syndromes, and requires surgery as the only valid treatment option. Routine diagnostic methods (frontal RX, panoramic RX and submentovertex RX) have serious limitations mainly due to the transfer from a three dimensional image to a two dimensional plane. The feasibility of such methods is poorly supported due to inherent projection errors (image magnification, cranial rotation) and identification errors (image quality, precision and reproducibility). The use of computer tomographies represents a substantial improvement in the sense of skeletal and soft tissue structures? reproduction precision. The interpretation of this new data source makes evi…
Head–Neck Cancer Delineation
2021
Head–Neck Cancer (HNC) has a relevant impact on the oncology patient population and for this reason, the present review is dedicated to this type of neoplastic disease. In particular, a collection of methods aimed at tumor delineation is presented, because this is a fundamental task to perform efficient radiotherapy. Such a segmentation task is often performed on uni-modal data (usually Positron Emission Tomography (PET)) even though multi-modal images are preferred (PET-Computerized Tomography (CT)/PET-Magnetic Resonance (MR)). Datasets can be private or freely provided by online repositories on the web. The adopted techniques can belong to the well-known image processing/computer-vision a…
Artefacts in CBCT: a review
2011
Artefacts are common in today's cone beam CT (CBCT). They are induced by discrepancies between the mathematical modelling and the actual physical imaging process. Since artefacts may interfere with the diagnostic process performed on CBCT data sets, every user should be aware of their presence. This article aims to discuss the most prominent artefacts identified in the scientific literature and review the existing knowledge on these artefacts. We also briefly review the basic three-dimensional (3D) reconstruction concept applied by today's CBCT scanners, as all artefacts are more or less directly related to it.
Cone beam computed tomography diagnostic imaging of intra-osseous mucoepidermoid carcinoma in the mandible
2017
Intra-osseous mucoepidermoid carcinoma in the mandible is a rarely reported entity, comprising only 2-3% of all mucoepidermoid carcinomas. Unilocular and/or multilocular radiolucency is characteristic of mucoepidermoid carcinoma, but has a radiographic appearance similar to that of odontogenic benign and malignant tumors and thus cannot be accurately diagnosed on plain films. This article describes a case of a 36-year-old man with intra-osseous mucoepidermoid carcinoma in the left mandible. For a detailed analysis, both panoramic radiograph and cone beam computed tomograph were taken. Important clinico-pathological and imaging features, differential diagnosis and review of the literature ar…
Impact of cone-beam computed tomography for the identification and management of an oral portal of entry in patients with infective endocarditis. A D…
2021
Background Infective endocarditis (IE) is a rare and life-threatening disease. Cutaneous portal of entry (POE) is predominant for IE, but an oral POE is the second most frequent source. Thus looking for and treating an oral POE in IE patients is of critical importance in order to reduce the risk of IE relapse or recurrence. The objectives of this study were: 1) To reach a consensus on decision-making following the detection of an oral POE on cone-beam computed tomography (CBCT) while they were not identified using the current recommended approach in IE patients (oral examination and orthopantomogram: OPT). 2) To determine whether this consensus differs when regarding the microbiology of IE.…
Comparison of the diagnostic efficacy of 2D radiography and cone beam computed tomography in persistent apical periodontal disease: A PRISMA-DTA syst…
2021
Objective The objective of this study was to answer the question: Do conventional radiographs (periapical/panoramic) afford better diagnostic outcomes than cone beam computed tomography (CBCT) as a complement for clinical diagnosis of apical lesions with persistent apical periodontitis or disease after root canal treatment? Study Design Five electronic databases were searched and provided information to enable construction of a table to determine primary diagnostic measures and secondary parameters. The evidence was appraised with the Quality Assessment of Diagnostic Accuracy Studies tool and GRADEpro software. Results Twenty-seven articles (9903 diagnostic images) were included. The pooled…
Technical and surgical aspects of the sphenopalatine ganglion (SPG) microstimulator insertion procedure
2015
Cluster headache (CH) is a debilitating, severe form of headache. A novel non-systemic therapy has been developed that produces therapeutic electrical stimulation to the sphenopalatine ganglion (SPG). A transoral surgical technique for inserting the Pulsante SPG Microstimulator into the pterygopalatine fossa (PPF) is presented herein. Technical aspects include detailed descriptions of the preoperative planning using computed tomography or cone beam computed tomography scans for presurgical digital microstimulator insertion into the patient specific anatomy and intraoperative verification of microstimulator placement. Surgical aspects include techniques to insert the microstimulator into the…
Clinical indications for cardiac computed tomography. From the Working Group of the Cardiac Radiology Section of the Italian Society of Medical Radio…
2012
"\"La tomografia computerizzata del cuore (CCT) è diventata uno strumento efficace in differenti contesti clinici. Lo sviluppo della tecnologia ha portato ad una progressiva espansione delle indicazioni con una concomitante riduzione della dose di radiazioni necessaria per l’esecuzione dell’indagine. Ancora oggi sono pochi i documenti delle maggiori società scientifiche internazionali che si esprimono sulle effettive modalità di utilizzo e sulle indicazioni cliniche della CCT; in particolare mancano delle linee guida complete. Questo documento rispecchia la visione del gruppo di lavoro della Sezione di Cardio-Radiologia della Società Italiana di Radiologia Medica in merito alle indicazioni …