Search results for "tomography"

showing 10 items of 2332 documents

Bone’s Structural Diversity in Adult Females Is Established before Puberty

2009

Bone must be rigid for leverage yet light for mobility. We studied how bone modeling and remodeling fashioned differences in bone size, shape, and mass during growth to achieve these properties in adulthood.We measured the structural features of a tibial cross-section using quantitative computed tomography and markers of remodeling in 258 10- to 13-yr-old girls during 2 yr and in 108 of their mothers.Tibia total cross-sectional area and mass correlated between daughters and their mothers (r = 0.34 and 0.44, respectively, both P0.01). The location of a daughter's tibial total cross-sectional area, medullar area, and bone mass in the lower, middle, or upper part of the sample distribution was…

Adultmedicine.medical_specialtyAdolescentEndocrinology Diabetes and Metabolismmedia_common.quotation_subjectClinical BiochemistryStructural diversityBiologyBiochemistryBone and BonesBone modelingFractures BoneEndocrinologyBone DensityInternal medicinemedicineHumansTibiaQuantitative computed tomographyChildmedia_commonBone mineralDaughterBone DevelopmentAnthropometryTibiamedicine.diagnostic_testPubertyBiochemistry (medical)Nutritional statusMiddle AgedEndocrinologyFemaleBone RemodelingBone massThe Journal of Clinical Endocrinology & Metabolism
researchProduct

Echocardiography in diagnosis of aortic dissection.

1989

In a multicentre study the accuracy of echocardiography was measured in 164 consecutive patients with suspected aortic dissection. The diagnosis was subsequently proven (82 patients) on the basis of transthoracic and transoesophageal echocardiography and additional diagnostic procedures, including computed tomography (CT), aortic angiography, and surgery and/or necropsy. The sensitivity and specificity of echocardiography were 99% and 98%, respectively, with positive and negative predictive values of 98% and 99%. For CT sensitivity was 83%, specificity 100%, and positive and negative predictive values 100% and 86%, respectively. For aortography sensitivity and specificity were 88% and 94%, …

Adultmedicine.medical_specialtyAortographyAorta ThoracicAortographyAneurysmPredictive Value of TestsPositive predicative valuemedicine.arterymedicineHumansMulticenter Studies as TopicAortaAgedAortic dissectionAged 80 and overAortamedicine.diagnostic_testbusiness.industryGeneral MedicineMiddle Agedmedicine.diseaseAortic AneurysmAortic DissectionEchocardiographyEvaluation Studies as TopicPredictive value of testsAngiographyAcute DiseaseTomographyRadiologyEmergenciesbusinessTomography X-Ray ComputedLancet (London, England)
researchProduct

Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT

2021

Purpose To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT). Methods We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ± 12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance. Results Mean LV wa…

Adultmedicine.medical_specialtyBiometryAnterior ChamberSignificant negative correlationPositive correlationSwept-source Fourier domainCorrelationLens thicknessOphthalmologyLens CrystallineHumansMedicineOptical coherence tomographybusiness.industrySpur-to-spurReproducibility of ResultsMean ageAxial lengthWhite-to-whiteMiddle AgedClinical routineCrystalline lens riseAxial Length Eyemedicine.anatomical_structureLens (anatomy)Original ArticlebusinessTomography Optical CoherenceOptometryJournal of Optometry
researchProduct

Double Endocrine Neoplasia in a Renal Transplant Recipient: Case Report and Review of the Literature

2011

Abstract Introduction The incidence of cancer compared for age groups is 3–4 times higher in transplant recipients than the general population. The increased risk is related to immunosuppressive therapy as well as the use of increasingly older donors and recipients. Although cardiovascular disease with a functioning transplant is the leading cause of death (47%), cancer mortality is significant especially among older patients. However, the most frequent posttransplantation cancers relate to hemolymphopoietic organs and skin, whereas the occurrence of solid tumors elsewhere is rare. Herein we have described a rare case of synchronous double malignancy of endocrine organs (thyroid-adrenal) in…

Adultmedicine.medical_specialtyBiopsymedicine.medical_treatmentAdrenal neoplasmSettore MED/08 - Anatomia PatologicaNephrectomyEndocrine neoplasia renal transplant recipientAdrenocortical CarcinomamedicineAdjuvant therapyHumansAdrenocortical carcinomaThyroid NeoplasmsMultiple endocrine neoplasiaThyroid cancerNeoplasm StagingTransplantationOxyphil Cellsbusiness.industryCarcinomaGraft SurvivalMultiple Endocrine NeoplasiaThyroidectomyAdrenalectomyMycophenolic Acidmedicine.diseaseKidney TransplantationAdrenal Cortex NeoplasmsCarcinoma PapillaryNephrectomySurgeryTransplantationSettore MED/18 - Chirurgia GeneraleTreatment OutcomeThyroid Cancer PapillaryCyclosporineThyroidectomyKidney Failure ChronicLymph Node ExcisionDrug Therapy CombinationFemaleSteroidsSurgeryTomography X-Ray ComputedbusinessImmunosuppressive AgentsTransplantation Proceedings
researchProduct

Bone metastasis of a breast cancer detected by 3'-deoxy-3'-18F-fluorothymidine PET/CT

2008

International audience

Adultmedicine.medical_specialtyBone NeoplasmsBreast NeoplasmsDocetaxel[SDV.IB.MN]Life Sciences [q-bio]/Bioengineering/Nuclear medicine030204 cardiovascular system & hematology01 natural sciencesBone and Bones[SDV.IB.MN] Life Sciences [q-bio]/Bioengineering/Nuclear medicine[ SDV.IB.MN ] Life Sciences [q-bio]/Bioengineering/Nuclear medicine03 medical and health sciences0302 clinical medicineBreast cancermedicineHumansRadiology Nuclear Medicine and imagingComputingMilieux_MISCELLANEOUSEpirubicinPET-CT010405 organic chemistrybusiness.industryBone metastasisGeneral Medicinemedicine.diseaseDideoxynucleosides3. Good health0104 chemical sciences18f fluorothymidineTreatment OutcomePositron-Emission TomographyFemaleTaxoidsRadiologybusinessTomography X-Ray Computed
researchProduct

The internal calcar septum and its contact with the virtual stem in THR: a computer tomographic evaluation.

2003

The internal calcar septum is a ridge of cortical bone protruding from the inner cortical wall of the proximal femur into the medullary canal. It extends from the lesser trochanter into the femoral neck and narrows the femoral cavity in its dorsal third. This region is essential for THR stability, but the degree of contact between the septum and standard THR implants has never been studied. We obtained CT scans of 50 arthrotic hip joints from patients requiring THR. Virtual stems (50 straight/wedge-shaped and 50 anatomic stems) were placed in CT images of the femora using a PC-based preoperative planning unit. The dimensions of the septum, degree and location of contact between the septum a…

Adultmedicine.medical_specialtyCalcarMedullary cavitybusiness.industryArthroplasty Replacement HipAnatomyRoboticsMiddle Agedmedicine.anatomical_structureLesser TrochanterOrthopedic surgerymedicineImage Processing Computer-AssistedHumansOrthopedics and Sports MedicineSurgeryCortical boneFemurImplantFemurHip ProsthesisbusinessTomography X-Ray ComputedFemoral neckActa orthopaedica Scandinavica
researchProduct

Hepatic Hilar and Sectorial Vascular and Biliary Anatomy in Right Graft Adult Live Liver Donor Transplantation

2008

Abstract Introduction The aim of this study was to analyze vascular and biliary variants at the hilar and sectorial level in right graft adult living donor liver transplantation. Methods From January 2003 to June 2007, 139 consecutive live liver donors underwent three-dimensional computed tomography (3-D CT) reconstructions and virtual 3-D liver partitioning. We evaluated the portal (PV), arterial (HA), and biliary (BD) anatomy. Results The hilar and sectorial biliary/vascular anatomy was predominantly normal (70%–85% and 67%–78%, respectively). BD and HA showed an equal incidence (30%) of hilar anomalies. BD and PV had a nearly identical incidence of sectorial abnormalities (64.7% and 66.2…

Adultmedicine.medical_specialtyCholecystographymedicine.medical_treatmentHilum (biology)Hepatic VeinsLiver transplantationliverHepatic ArteryImage Processing Computer-AssistedLiving DonorsmedicineHumansPorta hepatisTransplantationmedicine.diagnostic_testbusiness.industryGallbladderCholecystographyLiver TransplantationSurgeryTransplantationmedicine.anatomical_structureBiliary tractCirculatory systemSurgeryHepatectomyTomography X-Ray ComputedNuclear medicinebusinessTransplantation Proceedings
researchProduct

OCT for Assessing Artificial Tears Effectiveness in Contact Lens Wearers

2011

PURPOSE: To apply a commercially available high-resolution spectral domain optical coherence tomographer (SOCT) to assess the change in tear volume after application of a new artificial tears formulation specifically developed for contact lens (CL) users. METHODS: Twenty OD from young healthy CL wearers (mean age, 24.7 ± 3.5 years) with refractive errors ranging from -0.75 to -2.50 D (mean, -1.56 ± 0.69 D) were examined. All subjects were fitted with Focus Dailies CL (Ciba Vision), and two drops of Blink Contacts (AMO), lubricating formulation specifically developed for CL wearers, were instilled after baseline measures. Tear meniscus volume (TMV) was measured immediately after and 1 min, 1…

Adultmedicine.medical_specialtyContact Lensesmedicine.medical_treatmentMeniscus (anatomy)Tear volumeYoung AdultRegular distributionOphthalmologyImage Processing Computer-AssistedHumansMedicinebusiness.industryRepeated measures designContact Lenses HydrophilicRefractive ErrorsContact lensOphthalmologyArtificial tearsmedicine.anatomical_structureTear meniscusOftalmologíaDry Eye SyndromesEyelidOphthalmic SolutionsbusinessTomography Optical CoherenceFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Peliosis hepatis: spectrum of imaging findings

2006

OBJECTIVE. It is important to recognize the imaging characteristics of peliosis hepatis because peliotic lesions may mimic several different types of focal hepatic lesions CONCLUSION. We illustrate the spectrum of imaging findings of peliosis hepatis, including sonography, CT, MR, and angiography.

Adultmedicine.medical_specialtyDiagnosis DifferentialX ray computedmedicineHumansRadiology Nuclear Medicine and imagingPeliosis HepatismriUltrasonographyOvarian NeoplasmsIncidental Findingsmedicine.diagnostic_testbusiness.industryLiver DiseasesAngiographyMagnetic resonance imagingGeneral MedicineMiddle Agedmedicine.diseaseMagnetic Resonance ImagingCT imaging Liver Liver disease MRIct imagingLiverct imaging; liver; liver disease; mriAngiographyPeliosis hepatisFemaleRadiologyUltrasonographyCt imagingliver diseasebusinessTomography X-Ray ComputedLiver pathology
researchProduct

SPECT Bone scintigraphy of benign and malignant lesions of the spine

1989

70 patients were examined with planar and SPECT bone scintigraphy. SPECT proved to be superior over planar bone scanning for imaging of traumatic, inflammatory, and malignant bone lesions. SPECT provides three-dimensional information and, therefore, delineates the exact location and extension of lesions. It also has a higher sensitivity than planar bone scintigraphy. The three-dimensional bone scan generates complementary diagnostic information which often facilitates an adequate therapy protocol.

Adultmedicine.medical_specialtyDiagnostic informationHumansMedicineRachisTomography Emission-Computed Single-PhotonSpinal Neoplasmsmedicine.diagnostic_testbusiness.industryGeneral MedicineSpineVertebraBone scanningmedicine.anatomical_structureBone scintigraphyBone lesionPositron emission tomographyFemaleSpinal DiseasesSurgeryNeurology (clinical)NeurosurgeryRadiologybusinessNuclear medicineNeurosurgical Review
researchProduct