Hypofractionated postoperative helical tomotherapy in prostate cancer: a mono-institutional report of toxicity and clinical outcomes
2018
Francesco Cuccia,1,2 Gianluca Mortellaro,2 Vincenzo Serretta,3 Vito Valenti,1,2 Antonella Tripoli,1,2 Marina Gueci,1,2 Nicoletta Luca,1,2 Antonio Lo Casto,4 Giuseppe Ferrera2 1Radiation Oncology School, University of Palermo, Palermo, Italy; 2Radiation Oncology, ARNAS-Civico Hospital, Palermo, Italy; 3Section of Urology, Department of Surgical Oncological and Oral Science, University of Palermo, Palermo, Italy; 4Radiation Oncology School, Section of Radiological Sciences, DIBIMED, Università degli Studi di Palermo, Palermo, Italy Purpose: This is a mono-institutional study of acute and late toxicities and early biochemical control of a retrospective series of 75 prostate…
[11C]choline-PET-guided helical tomotherapy and estramustine in a patient with pelvic-recurrent prostate cancer: local control and toxicity profile a…
2010
[11C]choline positron emission tomograhy can be useful to detect metastatic disease and to localize isolated lymph node relapse after primary treatment in case of prostate-specific antigen failure. In case of lymph node failure in prostate cancer patients, surgery or radiotherapy can be proposed with a curative intent. Some reports have suggested that radiotherapy could have a role in local control of oligometastatic lymph node disease. This is the first reported case of [11C]choline positron emission tomography-guided helical tomotherapy concomitant with estramustine for the treatment of pelvic-recurrent prostate cancer. At 24 months after the end of helical tomotherapy, prostate-specific…
2021
Purpose First, this experimental study aims at comparing out-of-field doses delivered by three radiotherapy techniques (3DCRT, VMAT (two different accelerators), and tomotherapy) for a pediatric renal treatment. Secondly, the accuracy of treatment planning systems (TPS) for out-of-field calculation is evaluated. Methods EBT3 films were positioned in pediatric phantoms (5 and 10 yr old). They were irradiated according to four plans: 3DCRT (Clinac 2100CS, Varian), VMAT (Clinac 2100CS and Halcyon, Varian), and tomotherapy for a same target volume. 3D dose determination was performed with an in-house Matlab tool using linear interpolation of film measurements. 1D and 3D comparisons were made be…
Acute and late toxicity and preliminary outcomes report of moderately hypofractionated helical tomotherapy for localized prostate cancer: a mono-inst…
2019
Aims: To assess toxicity and clinical outcomes of moderately hypofractionated helical tomotherapy (HT) for the curative treatment of localized prostate cancer (PC). Methods: From December 2012 to May 2018, 170 patients were treated with definitive intent for PC. Thirty-four percent were low risk, 30% intermediate risk (IR) and 36% high risk (HR). All patients received 70 Gy in 28 fractions to the prostate; 61.6 Gy were delivered to the seminal vesicles for IR; pelvic lymph nodes irradiation for a total dose of 50.4 Gy was added in the HR subgroup. Toxicity was assessed using CTCAE V4.0, and biochemical failure was defined following Phoenix criteria. Time-to-event data were analyzed using th…
Moderate hypofractionated helical tomotherapy for prostate cancer in a cohort of older patients: a mono-institutional report of toxicity and clinical…
2019
Purpose or objective: To evaluate toxicity and outcomes of moderately hypofractionated helical tomotherapy for the curative treatment of a cohort of patients aged ≥ 75 years with localized prostate cancer (PC). Materials and methods: From January 2013 to February 2017, 95 patients with median age 77 years (range 75–88) were treated for PC. 39% were low risk, 33% intermediate risk (IR), 28% high risk (HR). Median iPSA was 9.42 ng/ml (1.6–107). Androgen deprivation was prescribed according to NCCN recommendations. All patients received 70 Gy in 28 fractions to the prostate; 61.6 Gy were delivered to the seminal vesicles for IR; whole pelvis irradiation with a total dose of 50.4 Gy was added i…
Inflammatory Pseudotumor of Mediastinum Treated with Tomotherapy and Monitored with FDG-PET/CT: Case Report and Literature Review
2010
Mediastinal inflammatory pseudotumor is a rare disease with reactive pseudoneoplastic features and a proven capacity for local invasion. The radiographic appearance of inflammatory pseudotumor is quite non-specific and the definitive diagnosis is based on the histological evaluation of tissue specimens. Resection of the lesion is the treatment of choice. However, nonsurgical treatments such as radiotherapy and steroids have been employed in the setting of incomplete surgical resection, tumor recurrence, and patients being unfit for surgery. The case described here is being reported because of the rare mediastinal location and atypical treatment approach including salvage irradiation and mon…
Moderate hypofractionated helical tomotherapy for localized prostate cancer: preliminary report of an observational prospective study.
2019
Objective: To report preliminary findings of a phase II study exploring the clinical outcomes of moderate hypofractionated radiotherapy performed with helical tomotherapy (HT) using computed tomography–magnetic resonance imaging–based planning for localized prostate cancer. Methods: The phase II prospective study received ethics approval from our institutional ethics committee. A dose of 60 Gy/20 fractions for low–intermediate risk prostate cancer by means of HT was explored. Primary endpoints of the study were acute and late gastrointestinal (GI) and genitourinary (GU) toxicities. Secondary endpoints were quality of life and biochemical-free survival. Results: A total of 35 patients were i…
EPR/alanine dosimetry for verification in Helical Tomotherapy Stereotactic Radiosurgery (HTSRS) treatments
2018
Introduction Intracranial stereotactic radiosurgery (SRS) is a technique to deliver an ablative radiation dose with an extremely sharp dose gradient to small brain tumors. In this study the accuracy of the dose delivered in SRS by a non conventional radiotherapy machine, the TomoTherapy Hi-Art System, was investigated using an "end-to-end" test using alanine pellets and gafchromic films. Methods Dose verifications were made using alanine dosimeters placed in an antropomorphic head phantom (Alderson Rando Phantom) under different treatment conditions in case of both single and multiple brain tumors. 1.25mm slice kVCT scan of the phantom was used to generate SRS plans on the TomoTherapy Plann…
Dose verification with EPR/alanine dosimeters in Helical Tomotherapy Stereotactic Radiosurgery (HT SRS) treatments
2016
Intracranial stereotactic radiosurgery (SRS) is a technique to deliver an ablative radiation dose with an extremely sharp dose gradient to small brain tumors. This tecnique allows to deliver high doses of radiation to the tumor sparing the surrounding healthy tissue. In this study the accuracy of the dose delivered in a SRS session by a non conventional radiotherapy machine, the TomoTherapy Hi-Art System, was investigated using an "end-to-end" test. This is perfome d by means of alanine Electron Paramagnetic Resonance (EPR) pe llets. The response of these dosimeters is compared to that of gafchromic films which are particularly suitable for two-dimensional dose verification providing accura…
Helical Tomotherapy® is a safe and feasible technique for total scalp irradiation
2017
Angiosarcoma of the scalp is a rare aggressive tumor that affects elderly patients. Chemoradiation is the treatment of choice for multicentric and extensive disease. The shape of the scalp represents a dosimetric challenge in terms of achieving a homogeneous concave dose distribution with coverage of the entire target volume and an acceptable organs-at-risk sparing. We report a case of an 81-year-old man with a multifocal angiosarcoma of the scalp treated with Helical TomoTherapy® (Accuray Inc., Sunnyvale, CA, USA) intensity modulated radiotherapy. This technique allows precise and daily verifiable coverage of the target keeping the dose to the organs at risk within the constraints.