Search results for "torque"
showing 10 items of 373 documents
A model for torque losses in variable displacement axial piston motors
2018
This paper includes a comparison of earlier presented models for torque losses in hydraulic motors and several proposed models that all rely on data typically available for a system engineer. The new models and the old ones are compared. The new models are all based on a model developed by Jeong 2007 with an expansion that include variable displacement. All of the new models yield very good accuracy down to approximately 50% of maximum displacement and down to approximately 15% of maximum speed. In these operational ranges the deviation in torque is less than 1%. The main purpose of the new models is to facilitate simulations of hydraulically actuated winches with a balance between accuracy…
Heat Pump Induction Motor Faults Caused by Soft Starter Topology — Case Study
2021
This paper presents a case study of electrical machine faults, emerging in heat pump systems. In Nordic countries, heat pumps have been gaining popularity during the past years and have become one of the leading ways of heating in households and smaller public buildings. Although not a very complicated setup, the devices used are still prone to unexpected failures, especially if wrongly chosen, installed or maintained. The paper presents a study conducted on five real-life cases with very similar outcomes and failure modes. The setup of the systems is explained, faults are listed and presented, causes of the faults including modeling and measurement data are provided. The suggestions are gi…
Dynamics of Torque Teno virus plasma DNAemia in allogeneic stem cell transplant recipients
2017
Abstract Background Torque Teno virus (TTV) plasma DNA load directly correlate with the level of immunosuppresion in different clinical settings. It is uncertain whether this may be the case in allogeneic hematopoietic stem cell transplant recipients (allo-HSCT). Objectives We characterized the dynamics of TTV DNAemia in patients undergoing T-cell replete allo-SCT. Study design Retrospective single-center observational study including 72 allo-HSCT patients. Plasma TTV DNA loads were quantified before initiating the conditioning regimen and at different time-points after transplant by real-time PCR. White blood cells (WBC) and absolute lymphocyte counts (ALC) were measured by flow cytometry.…
Early Post-Transplant Torquetenovirus Viremia Predicts Cytomegalovirus Reactivations In Solid Organ Transplant Recipients.
2018
AbstractMonitoring the human virome has been recently suggested as a promising and novel area of research for identifying new biomarkers which would help physicians in the management of transplant patients. Imbalance of the immune system in transplant recipients has a significant impact on replication of Torquetenovirus (TTV), the most representative and abundant virus of human virome. TTV kinetic was studied by real-time PCR in 280 liver or kidney transplant recipients who underwent different drug regimens to maintain immunosuppression. During one-year post-transplant follow-up, TTV viremia fluctuated irrespective of transplanted organ type but consistent with the immunosuppression regimen…
Detection of Torque Teno Virus (TTV) and TTV-Like Minivirus in patients with presumed infectious endophthalmitis in India
2020
Human anelloviruses (Torque Teno Virus (TTV) and TTV Like Mini Virus (TLMV)) are now being reported at a high prevalence across the world, with a controversial disease-inducing potential. The aim of this study was to investigate the role of these anellovirus in vitreous of patients with presumed infectious endophthalmitis. After informed consent, vitreous fluid from patients with endophthalmitis (n = 103) and non-infectious pathologies (n = 102) were analyzed for the presence of TTV and TLMV DNA by qPCR with the limit of quantification defined as 100 copies per reaction. Among the patients clinically diagnosed with endophthalmitis, 29 of the 40 culture proven samples (72.5%) and 42 out of 6…
Assessment of prevalence and load of torquetenovirus viraemia in a large cohort of healthy blood donors.
2020
OBJECTIVES: Torquetenovirus (TTV) is an emerging marker of functional immune competence with the potential to predict transplant-related adverse events. A large-scale epidemiological study was performed to understand how basal values vary in healthy individuals according to age and gender.; METHODS: We tested plasma from 1017 healthy blood donors aged 18-69years. The presence and load of TTV were determined by a real-time PCR assay. A sub-cohort of 384 donors was tested for anti-cytomegalovirus IgG antibodies, and 100 participants were also tested for TTV viraemia on a paired whole blood sample.; RESULTS: The overall prevalence of TTV was 65% (657/1017) with a mean (±SD) growth of 5±4% ever…
Accuracy combining different brands of implants and abutments
2013
Objective: To evaluate the vertical misfit between different brands of dental implants and prosthetic abutments, with or without mechanical torque, and to study their possible combination. Study design: Five different brands of implant were used in the study: Biofit (Castemaggiore, Italy), Bioner S.A. (Barcelona, Spain), 3i Biomet (Palm Beach, U.S.A.), BTI (Alava, Spain) and Nobel Biocare (Göteborg, Sweden), with standard 4.1 mm heads and external hexagons, and their respective machined prosthetic abutments. The implant-to- abutment fit/misfit was evaluated at four points (vestibular, lingual/palatine, mesial and distal) between implants and abutments of the same brand and different brands,…
Effect of undersized drilling on the stability of immediate tapered implants in the anterior maxillary sector. A randomized clinical trial.
2020
Background To evaluate the effect of undersized drilling on the primary and secondary stability of immediate implants placed in the anterior maxilla. Material and Methods A comparative randomized clinical trial was carried out in 30 healthy adults. Thirty tapered implants, 16 involving conventional drilling and 14 undersized drilling, were placed immediately after anterior maxillary tooth removal. Insertion torque and implant stability assessed by resonance frequency analysis (RFA) were evaluated at three different timepoints: at implant placement and 6 and 12 weeks post-implantation. The results were compared using parametric statistical tests. Results All implants showed adequate stabilit…
Modeling of Human Posturokinetic Movements by a Linear Feedback System: Relations among Feedback Coefficients
2002
This study describes a method of modeling human trunk and whole body backward bending and suggests a possible neural control strategy. The hypothesis was that the control system can be modeled as a linear feedback system, in which the torque acting at a given joint is a function of the state variables (angular positions and angular velocities). The linear system enabled representation of the feedback system by a gain matrix. The matrix was computed from the kinematics recorded by a movement analysis system and from the joint torques calculated by inverse dynamics. To validate the control model, a comparison was made between the angular kinematics yielded by the model and the experimental d…
Kinetics of torque teno virus DNA load in saliva and plasma following allogeneic hematopoietic stem cell transplantation
2018
Plasma torque teno virus (TTV) DNA load directly correlates with the degree of T-cell immune reconstitution early after allogeneic hematopoietic stem cell transplantation (allo-HSCT). Here, the kinetics of oral TTV DNA shedding was examined to assess whether quantitation of TTV DNA load in saliva may either replace or complement that in plasma for predicting lymphocyte (ALC) reconstitution after engraftment. This prospective observational study enrolled 38 nonconsecutive allo-HSCT recipients. Saliva and plasma specimens were collected at baseline (pretransplant) and at around days +30, +50, and +90 after allo-HSCT. TTV DNA was quantitated in both specimen types by real-time PCR. ALCs were m…