Search results for "transformer"
showing 10 items of 96 documents
Measurements on partial discharge in on‐site operating power transformer: a case study
2018
This study presents the case study of a substation in-service power transformer referred to the on-site partial discharge (PD) detection and evaluation methods. An original methodology for simultaneous application of three methods is proposed: electrical, acoustic and ultra-high frequency. Transformer is powered by the power grid and no external generator is required according to the proposed methodology. Furthermore, several possibilities of applying these concurrent measurements and benefits of such solution in terms of result interpretation, interference resistance and on-site measurement applicability are indicated. The proposed methodology allows for a fast, accurate and secure PD diag…
Electromagnetic and Thermal Modelling for Calculating Ageing Rate of Distribution Transformers
2018
Prediction of the lifetime for transformers is very important for maintenance and asset management. Finite element analysis was performed on a 5 MVA distribution transformers with aluminium foil-type windings and voltage rating 6600 V/23000 V. Electromagnetic modelling is implemented on the full three-phase transformer to calculate distributed losses, taking the skin effect into account. To reduce the computational burden, the distributed losses in one phase are used to analyse temperature rise in one phase of the transformer. The temperature rise results were used to determine the ageing rate of the transformer. Further, the influence of ambient temperature and cooling on the temperature r…
3D magnetic and thermal fields for in the transformer with homogenised amorphous C-core under high frequency
2017
A Simple Approach for Determination of Numerical Values of Ferrite Nonlinear Susceptibilities
2020
This article presents a straightforward approach for determination of numerical values of nonlinear susceptibilities of soft magnetic ferrites. It is shown that numerical values of susceptibilities can be calculated from the measured amplitudes of harmonics in the output voltage of ferrite core transformer. For this purpose, useful expressions for the susceptibilities are derived and as example, numerical values of the largest nonlinear susceptibilities those of the third and fifth orders are calculated. Additionally, errors of the measured susceptibilities also are determined. Based on the expressions obtained, the analysis of phase shifts between components of flux density on different fr…
Numerical values of MnZn ferrite nonlinear susceptibilities in a lossless approximation
2017
On the basis of expressions for nonlinear magnetic susceptibilities of soft ferrites obtained earlier the analysis of phase shifts between components of flux density on different frequencies and the magnetic field strength is carried out. Only the largest nonlinear susceptibilities those of third and fifth order are considered. It is shown that in the frequency range where losses are small and can be neglected the susceptibility of third order is negative but that of fifth order is positive. These statements allow explaining the shape of output voltage of toroidal transformer with soft ferrite core induced by strong harmonic field strength in the input. Numerical values of nonlinear suscept…
Experimental results on the economic management of a smart microgrid
2020
The aim of this paper is to assess economic benefits deriving from the adoption of a smart microgrid. To this end, a case study consisting of 250 houses connected to the distribution network through a MV/LV transformer substation has been investigated and implemented in the experimental microgrid built at the Polytechnic University of Bari, Italy. The analysis has been performed by comparing three different energy providers: the utility grid, the utility grid with the inclusion of non-programmable renewables generators, and the inclusion of such residential loads into a smart microgrid. The obtained results demonstrated that with the adoption of a smart microgrid significant costs savings c…
Technical Possibilities of Reducing the Sound Pressure Level Emitted into the Environment by a Power Transformer
2011
The subject presented in this paper refers to measurements and assessment of the corrected sound pressure level values (noise) occurring around a medium-power transformer. The paper presents the values of noise accompanying the operation of the power object before and after its modernization, which consisted in repeated core pressing and replacement of the cooling system. The main aim of the research work was the assessment of the influence of the repair work on the noise level emitted into the environment.
3‐D CALCULATION OF ZERO‐COMPONENT FLUX IN THREE‐PHASE THREE‐COLUMN TRANSFORMER
1994
The paper discusses the problem of space distribution of zero‐component magnetic flux generated in three‐column transformer. For 3‐D magnetic field calculation the method of integral equations was used. The numerical calculations were made for physical model of the transformer and compared with experimental results. The accuracy of the calculations of the magnetic field, achieved in the work, proves that the modelling may be used as a computer aided designing tool.
Power-Line Communication in Medium-Voltage System: Simulation Model and Onfield Experimental Tests
2012
The aim of this paper is to develop a complete model of a power-line communication (PLC) system operating on a medium-voltage (MV) network. The core-shield configuration was chosen for signal transmission in the power cables. In order to validate the developed model experimental, the medium-voltage network of the Favignana island was used to carry out detailed testing. The transmission was performed between two transformer substations in the presence of mains voltage (i.e., 24 kV). ST7540 FSK power-line transceivers, together with capacitive coupling interfaces, were used for the transmission and the reception of the communication signal. The correlation between the experimental measurement…
Fast fringe pattern phase demodulation using FIR Hilbert transformers
2016
This paper suggests the use of FIR Hilbert transformers to extract the phase of fringe patterns. This method is computationally faster than any known spatial method that produces wrapped phase maps. Also, the algorithm does not require any parameters to be adjusted which are dependent upon the specific fringe pattern that is being processed, or upon the particular setup of the optical fringe projection system that is being used. It is therefore particularly suitable for full algorithmic automation. The accuracy and validity of the suggested method has been tested using both computer-generated and real fringe patterns. This novel algorithm has been proposed for its advantages in terms of com…