Search results for "transformers"

showing 7 items of 17 documents

A Comparison of Special Bonding Techniques for Transmission and Distribution Cables under Normal and Fault Conditions

2021

In this article, a review of the existing special bonding techniques for medium voltage and high-voltage cables is presented. Special bonding techniques have the purpose of reducing sheath currents, thereby limiting copper losses and the reduction of the ampacity of cables. The literature review shows various bonding techniques and how these have evolved over the years thanks to new technologies. Simulations of each technique are performed in MATLAB/Simulink, to compare their strengths and drawbacks both under normal conditions and in the presence of a single-line-to-ground fault.

Normal conditionsComputer science020209 energy020208 electrical & electronic engineeringMechanical engineering02 engineering and technologyspecial bonding techniquesFault (power engineering)Industrial and Manufacturing EngineeringCross bondingSettore ING-IND/33 - Sistemi Elettrici Per L'EnergiaTransmission (telecommunications)Control and Systems EngineeringElectromagnetic coilreactance bondingHardware_INTEGRATEDCIRCUITS0202 electrical engineering electronic engineering information engineeringsheath bonding transformersAmpacityElectrical and Electronic EngineeringReduction (mathematics)MATLABcomputerVoltagecomputer.programming_language
researchProduct

Fake News Spreaders Detection: Sometimes Attention Is Not All You Need

2022

Guided by a corpus linguistics approach, in this article we present a comparative evaluation of State-of-the-Art (SotA) models, with a special focus on Transformers, to address the task of Fake News Spreaders (i.e., users that share Fake News) detection. First, we explore the reference multilingual dataset for the considered task, exploiting corpus linguistics techniques, such as chi-square test, keywords and Word Sketch. Second, we perform experiments on several models for Natural Language Processing. Third, we perform a comparative evaluation using the most recent Transformer-based models (RoBERTa, DistilBERT, BERT, XLNet, ELECTRA, Longformer) and other deep and non-deep SotA models (CNN,…

Settore ING-INF/05 - Sistemi Di Elaborazione Delle Informazionitext classificationcorpus linguisticSettore ING-INF/03 - Telecomunicazionifake newTwitterauthor profilingconvolutional neural networkdeep learningNatural Language Processing (NLP)user classificationfake news; misinformation; Natural Language Processing (NLP); transformers; Twitter; convolutional neural networks; text classification; deep learning; machine learning; user classification; author profiling; corpus linguistics; linguistic analysismachine learningtransformermisinformationlinguistic analysisInformation Systems
researchProduct

Can SegFormer be a True Competitor to U-Net for Medical Image Segmentation?

2023

The U-Net model, introduced in 2015, is established as the state-of-the-art architecture for medical image segmentation, along with its variants UNet++, nnU-Net, V-Net, etc. Vision transformers made a breakthrough in the computer vision world in 2021. Since then, many transformer based architectures or hybrid architectures (combining convolutional blocks and transformer blocks) have been proposed for image segmentation, that are challenging the predominance of U-Net. In this paper, we ask the question whether transformers could overtake U-Net for medical image segmentation. We compare SegFormer, one of the most popular transformer architectures for segmentation, to U-Net using three publicl…

[INFO.INFO-AI] Computer Science [cs]/Artificial Intelligence [cs.AI]Medical image segmentation UNet transformersUNettransformersMedical image segmentation
researchProduct

Experimental Evaluation on Narrow Band Power Line Communication in Medium and Low Voltage Smart Grids

2013

The aim of this work is to perform a feasibility study on the power line communication for the development of a new generation of interface devices (IDs) for smart grid and energy storage applications. More in detail, this paper deals with one of the most important issues on this topic, which is the communication system. Among the existing communication technologies, the study is focused on power line communications (PLCs). After an analysis of the state of the art in the field, the main aspects are analyzed, concerning the open issues on the use of PLCs, especially for medium voltage (MV) and low voltage (LV) systems. In this work the use of PLC in MV-LV networks is investigated, by means …

communication systems power system communication power transformers communication equipment testing narrow band power line communication attenuation smart gridsSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Metrological performances of voltage and current instrument transformers in harmonics measurements

2018

In the new electrical system scenario, the increasing presence of non-linear loads and renewable energy sources makes the measurement of harmonics an essential task. The accuracy of harmonic measurement firstly depends on the used instrument transformers for voltage and current sensing. Since the behavior of instrument transformers in non-sinusoidal conditions is not always well defined, this paper presents an experimental study on the metrological performances of current and voltage instrument transformers (CTs and VTs) in the presence of harmonics. Proper tests procedures are defined and measurement setups are developed for both CTs and VTs calibration. The analysis is carried out by usin…

instrument transformers020209 energy02 engineering and technologyInstrument TransformerHarmonic analysispower system meaurementsPhase AngleDistortionharmonics0202 electrical engineering electronic engineering information engineeringCalibrationElectronic engineeringMedicineSafety Risk Reliability and QualityInstrumentationbusiness.industry020208 electrical & electronic engineeringHarmonicPower System MeasurementcalibrationCurrent transformerMetrologyHarmonicsHarmonicbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

Current transformers effects on the measurement of harmonic active power in LV and MV networks

2011

The harmonic active power is used to determine the location of polluting loads, the direction of harmonic power flow and to estimate how consequential a certain current harmonic source is. The highest uncertainties, when measuring harmonic active power, are introduced by the current and voltage transducers. This paper presents experimental results which show the impact of current transformers (CTs) on the accuracy of the harmonic power measurements. An expression for the evaluation of the power error in distorted conditions was developed which can be easily utilized in the case of linear current transducers. It is shown how CTs cannot be considered linear transducers and how the higher the …

instrument transformersEngineeringVoltage and current harmonicsSwitched-mode power supplyAcousticsActive powerTransducersEnergy Engineering and Power TechnologyLinear currentsPower factorHarmonic powerLinear transducersPower errorsPower transformersVoltage transducersHarmonic analysisHarmonic analysisMaximum valuesCurrent transformerElectrical and Electronic EngineeringPower measurementPhase anglesAbsolute valuesHarmonic power flowTotal harmonic distortionbusiness.industryElectric power distributionCurrent harmonicsElectrical engineeringAC powerCurrent transformerMV networksHarmonicsAccuracy classElectric instrument transformersHarmonicPower system harmonicsCurrent transformers (CTs) instrument transformerspower measurement power system harmonics.businessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Compensation of Nonlinearity of Voltage and Current Instrument Transformers

2019

This paper aims at characterizing and improving the metrological performances of current and voltage instrument transformers (CTs and VTs) in harmonic measurements in the power system. A theoretical analysis is carried out to demonstrate that, due to the iron core nonlinearity, CT and VT output signal is distorted even when the input signal is a pure sine wave. Starting from this analysis, a new method for CT and VT characterization and compensation is proposed. In a first step, they are characterized in sinusoidal conditions and the harmonic phasors of the distorted output are measured; in the second step, these phasors are used to compensate the harmonic phasors measured in normal operati…

uncertainty.Materials sciencepower system measurementAcousticsHarmonics020208 electrical & electronic engineeringPhasorHarmonicinstrument transformers (ITs)02 engineering and technologypower qualitySignalCurrent transformerCompensation (engineering)Harmonic analysisSine waveDistortion0202 electrical engineering electronic engineering information engineeringHarmonicElectrical and Electronic EngineeringuncertaintySettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationIEEE Transactions on Instrumentation and Measurement
researchProduct