Search results for "uci"
showing 10 items of 5317 documents
Effect of suturing the femoral portion of a four-strand graft during an ACL reconstruction
2014
Purpose A suture passed along the part of the graft that will be inserted into the femoral tunnel is widely used by surgeons, because it could prevent the graft sliding on the femoral fixation device during pulling from the tibial side. The aim of this study was to evaluate the biomechanical effects of suturing the intratunnel femoral part of the graft during an anterior cruciate ligament (ACL) reconstruction. Methods Bovine digital extensor tendons and tibias were harvested from 20 fresh-frozen mature bovine knees ranging in age from 18 to 24 months. Quadruple-strand bovine tendons were passed through the tibial tunnel and secured distally with a bioabsorbable interference screw. In one ha…
Different mechanism of relaxation induced by aporphine alkaloids in rat uterus.
1993
Abstract We have examined the uterine relaxant action of three aporphine molecules (S-glaucine, S-boldine and R-apomorphine) in two experimental conditions, with and without calcium in the bathing solution, and compared these effects with those obtained with the calcium antagonists verapamil and diltiazem. The present study shows that the alkaloids relax the uterine muscle but with different mechanisms of action. In Ca2+-containing solution all three alkaloids relaxed the uterus previously contracted by KCl or acetylcholine, but in Ca2+-free medium only R-apomorphine was able to relax oxytocin-induced contraction. The calcium antagonists, verapamil and diltiazem, relaxed KCl- or acetylcholi…
Role of virtopsy in the post-mortem diagnosis of drowning.
2014
Purpose: Due to admitted limits of autopsy-based studies in the diagnosis of drowning, virtopsy is considered the new imaging horizon in these post-mortem studies. The aim of our study was to evaluate the role of virtopsy performed through computed tomography (CT) in the forensic diagnosis of drowning. Materials and methods: We retrospectively examined the CT data of four cadavers recovered from sea water and suspected to have died by drowning. Each patient underwent a full-body post-mortem CT scan, and then a traditional autopsy. Conclusion: To date, there are no autopsy findings pathognomonic of drowning. This study proves that virtopsy is a useful tool in the diagnosis of drowning in tha…
Agreement between 2 swept-source OCT biometers and a Scheimpflug partial coherence interferometer
2020
PURPOSE To evaluate the agreement between different parameters obtained with 2 swept-source optical coherence tomography (SS-OCT)-based biometers and 1 Scheimpflug camera with partial coherence interferometry (PCI). SETTING Single center, Oftalvist, Alicante, Spain. DESIGN Prospective case series. METHODS Biometry was performed in 49 eyes using 3 optical biometers: ANTERION SS-OCT, IOLMaster 700 SS-OCT, and Pentacam AXL PCI. Keratometry (K), J0 and J45 vectors, anterior chamber depth (ACD), central corneal thickness (CCT), white-to-white (WTW), lens thickness (LT), and axial length (AL) were measured with each device. Bland-Altman analysis was applied. RESULTS This study comprises 49 eyes o…
Comparison of biometric measurements using partial coherence interferometry and applanation ultrasound
2003
Abstract Purpose To compare and contrast axial length (AL) measurements assessed by ultrasound biometry and optical biometry. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Optical biometry and ultrasound biometry were performed in 360 eyes to measure AL. Results In eyes with a clear-appearing crystalline lens, there was a statistically significant median difference in AL measurements between the 2 methods in eyes with a normal or long length. In eyes with cataract, there was a statistically significant median difference in AL measurements in eyes with a normal or short length. In these cases, optical biometry produced larger readings than ultras…
EFSUMB Guidelines 2011: Comment on Emergent Indications and Visions
2012
The focus of this article is the emergent and potential indications of contrast-enhanced ultrasound (CEUS). Emergent applications of CEUS techniques include extravascular and intracavitary contrast-enhanced ultrasound, quantitative assessment of microvascular circulation for tumor response assessment, and tumor characterization using dynamic contrast-enhanced ultrasound (DCE-US). Potential indications for microbubble agents include novel molecular imaging and drug and gene delivery techniques, which have been successfully tested in animal models. "Comments and Illustrations of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Non-Liver Guidelines 2011" whi…
Ramucirumab in patients with previously treated advanced hepatocellular carcinoma: Impact of liver disease aetiology.
2021
BACKGROUND & AIMS Hepatocellular carcinoma (HCC) is a common complication of chronic liver disease with diverse underlying aetiologies. REACH/REACH-2 were global phase III studies investigating ramucirumab in advanced HCC (aHCC) following sorafenib treatment. We performed an exploratory analysis of outcomes by liver disease aetiology and baseline serum viral load. METHODS Meta-analysis was conducted in patients with aHCC and alpha-fetoprotein (AFP) ≥400 ng/mL (N = 542) from REACH/REACH-2 trials. Individual patient-level data were pooled with results reported by aetiology subgroup (hepatitis B [HBV] or C [HCV] and Other). Pre-treatment serum HBV DNA and HCV RNA were quantified using Roche CO…
Interreader Reliability of LI-RADS Version 2014 Algorithm and Imaging Features for Diagnosis of Hepatocellular Carcinoma: A Large International Multi…
2017
Purpose To determine in a large multicenter multireader setting the interreader reliability of Liver Imaging Reporting and Data System (LI-RADS) version 2014 categories, the major imaging features seen with computed tomography (CT) and magnetic resonance (MR) imaging, and the potential effect of reader demographics on agreement with a preselected nonconsecutive image set. Materials and Methods Institutional review board approval was obtained, and patient consent was waived for this retrospective study. Ten image sets, comprising 38-40 unique studies (equal number of CT and MR imaging studies, uniformly distributed LI-RADS categories), were randomly allocated to readers. Images were acquired…
Routine cardiac troponin assessment after percutaneous coronary intervention
2019
: Although the angiographic and procedural success of percutaneous coronary intervention (PCI) is now very high, some severe complications may still develop, including periprocedural myocardial infarction (MI). An accurate diagnosis of this condition is essential for guiding the clinical management, as these patients may need a tailored management. The current recommendations for diagnosing periprocedural myocardial infarction based on the fourth universal definition appear at first sight straightforward, but the clinical and prognostic significance of routine periprocedural cardiac troponin (cTn) assessment remains uncertain. The current scientific evidence suggests that the likelihood of …
Computer-assisted interpretation of flow cytometry data in hematology.
1996
A computer program has been developed for computer-assisted diagnosis (including subclassification) of flow cytometry data of acute leukaemias and non-Hodgkin lymphomas by means of artificial intelligence. The knowledge base for the system has been formulatedas semantic networks that describe physiological hematopoiesisas well as the pathological situation (eg., aberrant antigen expression) of hematological disorders. The semantic networks reflect the hierarchy of cells and their occurrence in diseases, the normal and pathological antigen expression patterns of cells, cell maturation, and the frequency of cell populations in normal blood and bone marrow. Using these semantic networks, the d…