Search results for "ultrasonography."

showing 10 items of 861 documents

Correlation of Tibial Low-Frequency Ultrasound Velocity with Femoral Radiographic Measurements and BMD in Elderly Women

2009

The ultrasonic axial transmission technique has been proposed as a method for cortical bone characterization. Using a low enough center frequency, Lamb modes can be excited in long bones. Lamb waves propagate throughout the cortical bone layer, which makes them appealing for characterizing bone material and geometrical properties. In the present study, a prototype low-frequency quantitative ultrasonic axial transmission device was used on elderly women (n = 132) to investigate the relationships between upper femur geometry and bone mineral density (BMD) and tibial speed of sound. Ultrasonic velocities (V) were recorded using a two-directional measurement set-up on the midtibia and compared …

musculoskeletal diseasesMaterials scienceAcoustics and UltrasonicsBone densityOsteoporosisBiophysicsRisk AssessmentFractures BoneAbsorptiometry PhotonBone DensitymedicineHumansMass ScreeningRadiology Nuclear Medicine and imagingFemurFemurTibiaOsteoporosis PostmenopausalMass screeningAgedUltrasonographyAged 80 and overBone mineralAnthropometryTibiaRadiological and Ultrasound Technologybusiness.industryUltrasoundAnatomymedicine.diseasemedicine.anatomical_structureFemaleCortical bonebusinessNuclear medicineUltrasound in Medicine & Biology
researchProduct

Long Term Leisure Time Physical Activity Has a Positive Effect on Bone Mass Gain in Girls

2009

The purpose of this 7-year prospective longitudinal study was to examine whether the level and consistency of leisure-time physical activity (LTPA) during adolescence affected the bone mineral content (BMC) and bone mineral density (BMD) attained at early adulthood. The study subjects were 202 Finnish girls who were 10 to 13 years of age at baseline. Bone area (BA), BMC, and BMD of the total body (TB), total femur (TF), and lumbar spine (L2–L4) were assessed by dual-energy X-ray absorptiometry (DXA). Scores of LTPA were obtained by questionnaire. Girls were divided into four groups: consistently low physical activity (GLL), consistently high (GHH), and changed from low to high (GLH) and fro…

musculoskeletal diseasesmedicine.medical_specialtyLongitudinal studyAdolescentEndocrinology Diabetes and MetabolismLeisure timePhysical activityPhysiologyPhysical exerciseMotor ActivityBone and BonesAbsorptiometry PhotonLeisure ActivitiesBone DensitymedicineHumansOrthopedics and Sports MedicineFemurProspective StudiesChildUltrasonographyBone mineralbusiness.industrymusculoskeletal systemCalcaneusPhysical therapyFemaleLumbar spinebusinessBone massJournal of Bone and Mineral Research
researchProduct

Upper Limb Interventions.

2019

Ultrasound has been reported to be a quick, cheap, and effective imaging modality to guide the interventional procedures in the musculoskeletal system. The use of ultrasound results in increased accuracy of needle placement associated with a reduction of complications. In the upper limb, ultrasound-guided procedures are applied to joints and soft tissues around the shoulder, elbow, wrist, and hand. This article reviews the clinical and technical aspects of the most common procedures performed in this anatomic area.

musculoskeletal diseasesmedicine.medical_specialtymedicine.medical_treatmentElbowPsychological interventionWrist030218 nuclear medicine & medical imagingUpper Extremity03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationMedicineHumansRadiology Nuclear Medicine and imagingReduction (orthopedic surgery)Ultrasonography Interventionalmedicine.diagnostic_testbusiness.industryUltrasoundSoft tissueInterventional radiologyGeneral Medicinemedicine.anatomical_structure030220 oncology & carcinogenesisTendinopathyUpper limbbusinessRadiologic clinics of North America
researchProduct

Specific distribution of cross-sectional area in each hamstring muscle of sprint runners and relationship between those and sprint performance

2018

pikajuoksijatmedicine.medical_specialtyreidetlihaksetPhysical Therapy Sports Therapy and Rehabilitationultrasonographypikajuoksubi-articular musclePhysical medicine and rehabilitationhamstringSprintrunningmedicineultraäänitutkimusOrthopedics and Sports Medicineta315HamstringMathematicsJapanese Journal of Physical Fitness and Sports Medicine
researchProduct

Achilles tendon viscoelastic properties and mechanical responses to a single bout of exercise

2014

rasitusvammatviskositeettiultrasonographyliikuntafyysinen kuormitushyperthermiafyysinen kuormittavuuskimmoisuusjänteetstiffnesshysteresisfatigue damageultraäänitutkimuskantajännebiomekaniikkaliikuntavammatväsyminenhypertermiatendon fatigue
researchProduct

Foot and Lower Limb Clinical and Structural Changes in Overuse Injured Recreational Runners Using Floating Heel Shoes: Preliminary Results of a Rando…

2021

Foot-strike and the associated load rate are factors related to overuse injuries in runners. The purpose of this study was to analyse structural and functional changes in runners using floating heel running shoes, compared with runners using conventional footwear. A randomised control trial was conducted. Twenty runners with overuse injuries were followed over a 12-week gait retraining programme using floating heel running shoes or their conventional footwear. Pain was measured with pressure pain thresholds (PPTs), structural changes were measured with ultrasonography, and severity and impact of injury was scored on the Oslo Sports Trauma Research Centre Overuse Injury Questionnaire (OSTRC-…

running footwearmusculoskeletal diseasesmedicine.medical_specialtyHeelgait retrainingOveruse InjuryTP1-1185BiochemistryArticleLower limbAnalytical Chemistryrunning; gait retraining; foot; overuse injury; pain management; running footwearrunningotorhinolaryngologic diseasesHumansMedicineElectrical and Electronic EngineeringSports activityGaitInstrumentationbusiness.industryGait retrainingoveruse injuryChemical technologyTrauma researchAtomic and Molecular Physics and OpticsBiomechanical PhenomenaShoesbody regionsmedicine.anatomical_structureLower Extremitypain managementfootPhysical therapyHeelUltrasonographybusinesshuman activitiesFoot (unit)Sensors; Volume 21; Issue 23; Pages: 7814
researchProduct

Ultrasound bioeffects in rats: quantification of cellular damage in the fetal liver after pulsed Doppler imaging

2011

Objective To determine whether pulsed Doppler examination of the ductus venosus in rat fetuses could damage exposed tissue. Methods On gestational day 18, the livers of a mean of approximately five fetuses per mother (n = 5.14, SD = 1.6), in a cohort of 35 pregnant female rats, were exposed individually to pulsed Doppler and these were considered the 'exposed group'. The remaining fetuses in each pregnant rat (n = 5.16, SD = 2.1) formed the 'control group'. We tested for 600, 300, 60, 20, 15, 10 and 3 s of exposure of the fetal ductus venosus and the damage was evaluated measuring a cell death index of apoptotic activity at 7 h post-exposure (n = 16). In addition, subgroups of mothers were …

safetyPathologymedicine.medical_specialtyTime FactorsApoptosisWistar ratUltrasonography Prenatalductus venousFetusPregnancymedicineAnimalsRadiology Nuclear Medicine and imagingRats WistarVeinFetusPregnancyPulsed dopplerRadiological and Ultrasound Technologybusiness.industryUltrasoundDopplerObstetrics and GynecologyGeneral Medicinemedicine.diseaseRatsmedicine.anatomical_structureLiverReproductive MedicineUltrasonography Doppler PulsedApoptosisGestationFemalebusinessDuctus venosus
researchProduct

A Shape-based Statistical Method to Retrieve 2D TRUS-MR Slice Correspondence for Prostate Biopsy

2012

International audience; This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires the knowledge of the spatial position of the TRUS slice and this is only possible with the use of an electro-magnetic (EM) tracker attached to the TRUS probe. Since, the use of EM tracker is not common in clinical practice and 3D TRUS is not used during biopsy, we propose to per…

shape-contextProstate biopsyComputer science[INFO.INFO-IM] Computer Science [cs]/Medical Imaging030230 surgeryTranslation (geometry)[ INFO.INFO-CV ] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]urologic and male genital diseasesRectal ultrasound030218 nuclear medicine & medical imagingProstate biopsy03 medical and health sciences0302 clinical medicine[INFO.INFO-CV] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]ProstateBiopsymedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingComputer visionnormalized mutual information.normalized mutual informationmedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industry[INFO.INFO-CV]Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Magnetic resonance imagingTissue samplingmedicine.anatomical_structure2D TRUS/3D MR correspondenceArtificial intelligenceUltrasonographybusiness
researchProduct

High-Frequency and Ultra-High Frequency Ultrasound: Musculoskeletal Imaging up to 70 MHz

2020

AbstractMusculoskeletal (MSK) ultrasound has well-established advantages, able to investigate very small structures with high resolution and a quick and real-time dynamic evaluation with the possibility of contralateral comparison. Thus ultrasound has kept its own almost exclusive fields of application in daily clinical practice, and it is considered the first-level imaging technique to assess tendons, bursae, and capsuloligamentous structures of small peripheral joints as well as peripheral nerves. Up to now, however, clinical MSK ultrasound imaging could not go beyond the first 1 to 2 cm under the skin, using high-frequency probes up to 18 to 20 MHz with spatial resolution just below mill…

tendonTransducersHigh resolutionSkin Diseases030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineTendon InjuriesMedicineHumansRadiology Nuclear Medicine and imagingOrthopedics and Sports MedicineMusculoskeletal DiseasescartilageImage resolutionMusculoskeletal System030203 arthritis & rheumatologyMusculoskeletal imagingbusiness.industryUltrasoundPeripheral Nervous System DiseasesultrasonographyClinical Practicecartilage; peripheral nerve; tendon; ultra-high frequency ultrasonography; ultrasonographyUltra high frequencyultra-high frequency ultrasonographyperipheral nerveUltrasound imagingImaging techniquebusinessBiomedical engineering
researchProduct

Ultrasonography of the Liver

2011

ultrasonographyliverSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct