Search results for "validation"
showing 10 items of 620 documents
Influence of the Geriatric Oncology Consultation On the Final Therapeutic Decision In Elderly Subjects With Cancer: Analysis of 191 Patients
2014
International audience; Objectives: evaluate the impact of the Geriatric Oncology consultation on the final therapeutic management of cancer in elderly patients aged 70 and older. Design: retrospective study. Setting: the Pilot coordination unit in Geriatric Oncology of Cote d'Or, Burgundy, France. Participants: From January 2010 to December 2010, 191 patients with cancer aged 70 and older. Measurements: the concordance between the treatments proposed following the tumor Board, those proposed following the Geriatric evaluation (GE) and those actually given to the patients was evaluated using the kappa agreement test. Results: One hundred and ninety-one patients were included. Mean age was 8…
How accurate is the reporting of stroke in hospital discharge data? A pilot validation study using a population-based stroke registry as control.
2012
Population-based stroke registries can provide valid stroke incidence because they ensure exhaustiveness of case ascertainment. However, their results are difficult to extrapolate because they cover a small population. The French Hospital Discharge Database (FHDDB), which routinely collects administrative data, could be a useful tool for providing data on the nationwide burden of stroke. The aim of our pilot study was to assess the validity of stroke diagnosis reported in the FHDDB. All records of patients with a diagnosis of stroke between 2004 and 2008 were retrieved from the FHDDB of Dijon Teaching Hospital. The Dijon Stroke Registry was considered as the gold standard. The sensitivity, …
Structural validity of the Finnish Manchester-Oxford Foot Questionnaire (MOXFQ) using the Rasch model.
2019
Background: The 16-item patient-reported Manchester-Oxford Foot Questionnaire (MOXFQ) with subscales of pain, social interactions, and walking/standing has been claimed for strongest scientific evidence in measuring foot and ankle complaints. This study tests the validity of the Finnish MOXFQ for orthopaedic foot and ankle population using the Rasch analysis. Methods: We translated the MOXFQ into Finnish and used that translation in our study. MOXFQ scores were obtained from 183 patients. Response category distribution, item fit, coverage, targeting, item dependency, ability to measure latent trait (unidimensionality), internal consistency (Cronbach's alpha), and person separation index (PS…
Validity of the Novel Taiwan Lymphoscintigraphy Staging and Correlation of Cheng Lymphedema Grading for Unilateral Extremity Lymphedema
2018
Objective: The aim was to validate the new Taiwan Lymphoscintigraphy Staging, correlate it with Cheng Lymphedema Grading (CLG) and evaluate the treatment outcomes of unilateral extremity lymphedema. Background: No consensus has been reached for diagnosis and staging for patients with lymphedema among medical specialties. Methods: We included 285 patients with unilateral extremity lymphedema using lymphoscintigraphy. Lymphoscintigraphy was correlated to clinical symptoms and signs, and classified into normal lymphatic drainage, partial obstruction, and total obstruction. Inter- and intraobserver reliability of Taiwan Lymphoscintigraphy Staging, correlation between Taiwan Lymphoscintigraphy S…
Reliability and validity of the Finnish version of the prosthesis evaluation questionnaire
2018
Background: Thus far there have been no specific patient-reported outcome instrument in Finnish for health-related quality of life (HRQoL) assessment after major lower extremity amputation and successful prosthesis fitting. Methods: The prosthesis evaluation questionnaire (PEQ) was translated and cross-culturally adapted into Finnish. Participants completed a questionnaire package including the Finnish version of the PEQ and the 15 D HRQoL instrument. Scales (n = 10) were tested for internal consistency, floor-ceiling effect, and reproducibility for which participants completed the PEQ twice within a 2-week interval. Validity was tested by estimating the correlation between the 15 D index a…
Positive and Negative Affect Schedule (PANAS): psychometric properties of the online Spanish version in a clinical sample with emotional disorders
2020
Abstract Background The Positive and Negative Affect Schedule (PANAS) is the most widely and frequently used scale to assess positive and negative affect. The PANAS has been validated in several languages, and it has shown excellent psychometric properties in the general population and some clinical samples, such as forensic samples, substance users, and adult women with fibromyalgia. Nevertheless, the psychometric properties of the scale have not yet been examined in clinical samples with anxiety, depressive, and adjustment disorders. In addition, the proliferation of Internet-based treatments has led to the development of a wide range of assessments conducted online with digital versions …
Validity of five foot and ankle specific electronic patient-reported outcome (ePRO) instruments in patients undergoing elective orthopedic foot or an…
2019
Background: Patient-reported outcomes (PROS) are widely accepted measures for evaluating outcomes of surgical interventions. As patient-reported information is stored in electronic health records, it is essential that there are valid electronic PRO (ePRO) instruments available for clinicians and researchers. The aim of this study was to evaluate the validity of electronic versions of five widely used foot and ankle specific PRO instruments. Methods: Altogether 111 consecutive elective foot/ankle surgery patients were invited face-to-face to participate in this study. Patients completed electronic versions of the Foot and Ankle Ability Measure (FAAM), the Foot and Ankle Outcome Score (FAOS),…
Variability in protein binding of teicoplanin and achievement of therapeutic drug monitoring targets in critically ill patients: Lessons from the DAL…
2014
The aims of this study were to describe the variability in protein binding of teicoplanin in critically ill patients as well as the number of patients achieving therapeutic target concentrations. This report is part of the multinational pharmacokinetic DALI Study. Patients were sampled on a single day, with blood samples taken both at the midpoint and the end of the dosing interval. Total and unbound teicoplanin concentrations were assayed using validated chromatographic methods. The lower therapeutic range of teicoplanin was defined as total trough concentrations from 10 to 20 mg/L and the higher range as 10-30 mg/L. Thirteen critically ill patients were available for analysis. The followi…
Formulation and validation of a reduced order model of 2D materials exhibiting a two-phase microstructure as applied to graphene oxide
2018
Abstract Novel 2D materials, e.g., graphene oxide (GO), are attractive building blocks in the design of advanced materials due to their reactive chemistry, which can enhance interfacial interactions while providing good in-plane mechanical properties. Recent studies have hypothesized that the randomly distributed two-phase microstructure of GO, which arises due to its oxidized chemistry, leads to differences in nano- vs meso‑scale mechanical responses. However, this effect has not been carefully studied using molecular dynamics due to computational limitations. Herein, a continuum mechanics model, formulated based on density functional based tight binding (DFTB) constitutive results for GO …
Elastoplastic Damaging Model for Adhesive Anchor Systems. II: Numerical and Experimental Validation
2011
This paper presents the numerical and experimental validation of the analytical elastoplastic damaging model proposed in the companion paper (Part I). The validation was carried out by describing the pullout failure of epoxy adhesive anchors. Pullout tests were simulated numerically and performed experimentally. Several specimens made of a rebar embedded in a hardened concrete cylinder by means of polyester resin were tested. Conventional strain gauges and acoustic emission (AE) sensors were used to evaluate the structural response of the system and to monitor the onset and progression of structural damage, respectively. The parametric analysis and the moment tensor analysis of the AE data …