Search results for "valve"
showing 10 items of 576 documents
Cancer patients requiring interruption of long-term warfarin because of surgery or chemotherapy induced thrombocytopenia: The use of fixed sub-therap…
2012
No data are available regarding the management of cancer patients requiring interruption of long-term vitamin-K antagonist (VKA) therapy. For this purpose, we tested the efficacy and safety of fixed doses of low-molecular weight heparin (LMWH) in substitution of VKA because of invasive procedures or chemotherapy-induced thrombocytopenia. In cancer patients on VKA, therapy was discontinued 5 ± 1 days before surgery or chemotherapy. Heparin was given at prophylactic dosage in patients at low risk and at fixed subtherapeutic doses (3,800 or 4,000 UI anti-FXa, b.i.d.) in those at high-risk for thrombosis. LMWH was reinitiated 12 hr after surgery and VKA the day after. In patients receiving chem…
100 cases of Mainz pouch: continuing experience and evolution.
1988
The surgical technique for creation of the Mainz pouch uses 10 to 15 cm. of cecum and ascending colon and 2 ileal loops of the same length for construction of a urinary reservoir. Initial applications of the Mainz pouch were for bladder augmentation after subtotal cystectomy and for continent urinary diversion. Current indications have been extended to complete bladder substitution after radical cystoprostatectomy with anastomosis of the pouch to the membranous urethra. For cosmetic reasons the umbilicus is used as a stomal site for continent urinary diversion, and the technique of intussuscepting the continence nipple has been modified accordingly. A total of 100 patients underwent a Mainz…
Cardiac disease in patients with mucopolysaccharidosis: presentation, diagnosis and management
2011
The mucopolysaccharidoses (MPSs) are inherited lysosomal storage disorders caused by the absence of functional enzymes that contribute to the degradation of glycosaminoglycans (GAGs). The progressive systemic deposition of GAGs results in multi-organ system dysfunction that varies with the particular GAG deposited and the specific enzyme mutation(s) present. Cardiac involvement has been reported in all MPS syndromes and is a common and early feature, particularly for those with MPS I, II, and VI. Cardiac valve thickening, dysfunction (more severe for left-sided than for right-sided valves), and hypertrophy are commonly present; conduction abnormalities, coronary artery and other vascular in…
Ileocecal valve reconstruction during continent urinary diversion.
1994
During construction of an ileocecal reservoir, such as the Mainz or Indiana pouch, the ileocecal valve is lost. Subsequently, the intestinal transit time is shortened and malabsorption as well as diarrhea may result. Patients having undergone previous bowel resection as well as children with myelomeningocele who often already have frequent defecations will be heavily affected by the loss of the ileocecal valve. We have functionally reconstructed the ileocecal valve by embedding ileum into the ascending colon via a submucosal tunnel in analogy to the technique used when creating the continence mechanism during the Mainz pouch procedure using the appendix. Experimental results in 15 dogs demo…
Clinical relevance of vegetation localization by transoesophageal echocardiography in infective endocarditis
1992
Infective endocarditis is associated with significant morbidity and mortality, with valvular destruction and congestive heart failure being more common in patients with echocardiographically discernible vegetations. The transoesophageal approach affords consistently high quality images with excellent structural resolution. Two-hundred and eighty-one patients with clinically suspected infective endocarditis were studied, to evaluate the prognostic value of ascertaining the site of vegetations. Among them were 118 patients with vegetations attached to the aortic or mitral valve. These patients were followed for a mean period of 14 months. Mitral valve vegetations were associated with a signif…
Prediction of rapid versus prolonged healing of infective endocarditis by monitoring vegetation size.
1991
The diagnostic value of transesophageal echocardiography in monitoring the clinical course has been evaluated in 83 patients with echocardiographic evidence of infective endocarditis. A total of 103 vegetations attached to the aortic or mitral valves were detected by use of the transesophageal approach. The patients were monitored for a mean of 74 weeks and underwent a minimum of two consecutive transesophageal echocardiographic examinations. Group A included patients with increasing or remaining constant size of vegetation (8.2 +/- 1.5 to 11.2 mm, p less than 0.05) during 4 to 8 weeks of antimicrobial therapy, whereas group B was formed by patients with decreasing vegetation size (8.3 +/- …
Left ventricular diastolic filling alterations in subjects with mitral valve prolapse: A Doppler echocardiographic study
1993
To assess left ventricular diastolic filling in mitral valve prolapse (MVP), we studied 22 patients with idiopathic MVP and 22 healthy controls matched for sex, age, body surface area and heart rate. A two-dimensional, M-mode and Doppler echocardiographic examination was performed to exclude any cardiac abnormalities. The two groups had similar diastolic and systolic left ventricular volumes, left ventricle mass and ejection fraction. Doppler measurements of mitral inflow were: E and A areas (the components of the total flow velocity-time integral in the early passive period of ventricular filling, E; and the late active period of atrial emptying, A), the peak E and A velocities (cm.s-1), a…
Quantification of mitral valve stenosis by three-dimensional transesophageal echocardiography
1996
The aim of this study was the evaluation of the diagnostic potentials of transesophageal 3D- echocardiography in the determination of mitral valve stenosis. 54 patients were investigated by transthoracic and multiplane transesophageal echocardiography. In 41 patients cardiac catheterization was performed. 3D- echocardiographic data acquisition was performed by automatic transducer rotation at 2 degree increments over a span of 180 degrees. The transesophageal probe was linked to an ultrasound unit and to a 3D- workstation capable of ECG- and respiration gated data acquisition, postprocessing and 2D/3D image reconstruction. The mitral valve was visualized in sequential cross-sectional planes…
Wireless Capsule Endoscopy in a Patient with Obscure Occult Bleeding
2002
A case of obscure/occult bleeding in a 39-year old man with a 7-year history of chronic fatigue and iron-deficiency anemia is presented here. Esophagogastroduodenoscopy, push enteroscopy, ileocolonoscopies, and a magnetic resonance imaging small-bowel follow-through did not reveal any abnormalities. Multiple inflammatory lesions with fibrin-covered ulcers and petechial bleeding in the area of the lower jejunum and ileum were diagnosed only with capsule endoscopy. One ulcer located near the ileocecal valve was then biopsied during a repeat ileocolonoscopy, and the histology showed signs of Crohn's enteritis. The further treatment approach was changed, with medical treatment being initiated a…
Detection of spontaneous echocardiographic contrast within the left atrium by transesophageal echocardiography: spontaneous echocardiographic contrast
1986
Transesophageal echocardiography was performed in 314 patients over a period of 24 months using a 3.5 MHz phased-array system fitted to the distal end of a conventional 12 mm endoscope. In 12 patients (2.6%) transesophageal echocardiography could not be performed because of adverse reaction to the gastroscopic procedure. Side effects were a transient A-V block in one patient and asthmatic attack in another. Mitral valve lesions were found in 99 of 314 patients. In 9 of these 99 patients (11%), including 1 patient with mitral valve stenosis and sinus rhythm, 2 with atrial fibrillation, 3 with disc, and 3 with porcine mitral prosthesis, spontaneous echocardiographic contrast was found within …