Search results for "ventilation"
showing 10 items of 476 documents
Assessment of a pilot system for seawater desalination based on vacuum multi-effect membrane distillation with enhanced heat recovery
2018
Abstract This work presents the evaluation of an innovative system based on vacuum multi-effect membrane distillation modules (V-MEMD) for seawater desalination at pilot scale. This four-effect unit introduces a remarkable modification from previous V-MEMD systems, consisting of the use of the seawater feed flow as cooling in the condenser, rather than a separate circuit. Preheating the feed in the condenser improved heat efficiency (maximum gained output ratio obtained for seawater was 3.2). Maximum distillate fluxes reached 8.5 l h−1 m−2 for hot feed temperature 75 °C and feed flow rate 150 l h−1. Increasing both parameters to raise the productivity was hindered by the inability of the co…
Personalized intraoperative positive end-expiratory pressure: a further step in protective ventilation
2017
Tissue Oxygenation in Normal and Edematous Brain Cortex During Arterial Hypocapnia
1984
Since arterial hypocapnia causes a cerebral blood flow decrease, hypocapnic conditions are induced in patients with severe traumatic brain injury by controlled hyperventilation in order to reduce the intracranial pressure (Gordon, 1971). Beneficial effects on the clinical course of patients, however, can be observed only under conditions of moderate hypocapnia. As shown by animal experiments severe arterial hypocapnia results in insufficient oxygen supply conditions in brain tissue (Grote et al., 1981), which subsequently influences the brain metabolism (Granholm et al., 1969, 1971) and counteracts the influence of hypocapnia on cerebral blood flow regulation (Grote et al., 1981). The prese…
Ventilation/perfusion ratios measured by multiple inert gas elimination during experimental cardiopulmonary resuscitation
2014
Background During cardiopulmonary resuscitation (CPR) the ventilation/perfusion distribution (VA/Q) within the lung is difficult to assess. This experimental study examines the capability of multiple inert gas elimination (MIGET) to determine VA/Q under CPR conditions in a pig model. Methods Twenty-one anaesthetised pigs were randomised to three fractions of inspired oxygen (1.0, 0.7 or 0.21). VA/Q by micropore membrane inlet mass spectrometry-derived MIGET was determined at baseline and during CPR following induction of ventricular fibrillation. Haemodynamics, blood gases, ventilation distribution by electrical impedance tomography and return of spontaneous circulation were assessed. Inter…
Parked Electric Vehicle’s Cabin Temperature Management Using Photovoltaic Powered Ventilation
2017
Abstract This paper presents how the electric vehicle roof integrated photovoltaic (PV) powered ventilation can be used for controlling the climate of the car. In this work, a fully-functional Renault Zoe electric car has been used to conduct experiments for PV powered ventilation. These experiments have been part of a wider research project of testing electric vehicles of the Edinburgh Napier University’s Transport Research Institute. The present work illustrates performance evaluation of electric car ventilation, when roof-mounted PV modules were used to operate DC powered fans for ventilation. It was found that the motor-fan selection for removing the warm air from cabin space is of impo…
The effectiveness of various types of ventilation on air quality in multi-family buildings
2017
Przepisy prawne oraz normy obligują do kontroli systemów wentylacji budynków jedynie pod względem prędkości strumienia powietrza, co niestety nie zawsze gwarantuje zalecaną ze względów zdrowotnych jakość powietrza. W pracy podjęto badania skuteczności różnych typów wentylacji wielorodzinnych budynków mieszkalnych, ze szczególnym uwzględnieniem wentylacji naturalnej, stanowiącej najczęściej spotykane rozwiązanie w budynkach mieszkalnych w Polsce. Badano wpływ skuteczności wentylacji na podstawowe parametry charakteryzujące jakość powietrza, tj. stężenie ditlenku węgla, wilgotność względną oraz temperaturą. Badano również możliwość regulacji pracy systemu wentylacji budynków wielorodzinnych w…
Badania skuteczności wentylacji pomieszczeń sypialni w wielorodzinnych budynkach mieszkalnych
2017
Skuteczność systemów wentylacji budynków mieszkalnych kontrolowana jest jedynie poprzez pomiar prędkości strumienia powietrza w kanale wentylacyjnym, co nie gwarantuje odpowiedniej kontroli jakości powietrza. W pracy przedstawiono wyniki badań skuteczności wentylacji naturalnej wielorodzinnych budynków mieszkalnych, stanowiącej najczęściej spotykane rozwiązanie w budynkach mieszkalnych w Polsce. Szczególną uwagę zwrócono na wentylację pomieszczenia sypialni, jako pomieszczenia, w którym spędza się około 1/3 czasu w ciągu dnia. Badano wpływ skuteczności systemu wentylacji na podstawowe parametry charakteryzujące jakość powietrza, tj. stężenie ditlenku węgla, wilgotność względną oraz temperat…
Withholding and withdrawing in real life
2018
IAQ monitoring in heritage buildings
2005
Heritage buildings often operate in free conditions, as they are not equipped with HVAC systems. This calls for the interventions of proper measurements with the aim of monitoring and controlling indoor physical parameters. As matter of fact, the control of indoor conditions in museums is of paramount importance for the proper preservation of artefacts. Moreover, in such buildings another requirement should be achieved, that is the maintenance of the comfort and safety conditions for visitors. In this work the results of a survey carried out on a hall of a historical palace to estimate the people occupancy by making use concentration of CO(2) are reported.