Search results for "ventricle"

showing 10 items of 431 documents

Atrial activity extraction for atrial fibrillation analysis using blind source separation.

2004

This contribution addresses the extraction of atrial activity (AA) from real electrocardiogram (ECG) recordings of atrial fibrillation (AF). We show the appropriateness of independent component analysis (ICA) to tackle this biomedical challenge when regarded as a blind source separation (BSS) problem. ICA is a statistical tool able to reconstruct the unobservable independent sources of bioelectric activity which generate, through instantaneous linear mixing, a measurable set of signals. The three key hypothesis that make ICA applicable in the present scenario are discussed and validated: 1) AA and ventricular activity (VA) are generated by sources of independent bioelectric activity; 2) AA …

Computer scienceSpeech recognitionHeart VentriclesBiomedical EngineeringSignalBlind signal separationSensitivity and SpecificityElectrocardiographyRobustness (computer science)Heart Conduction SystemAtrial FibrillationmedicineHumansDiagnosis Computer-AssistedHeart AtriaPrincipal Component Analysismedicine.diagnostic_testBody Surface Potential MappingContrast (statistics)Reproducibility of ResultsAtrial fibrillationmedicine.diseaseIndependent component analysisKurtosisElectrocardiographyAlgorithmsIEEE transactions on bio-medical engineering
researchProduct

2020

One crucial parameter to evaluate the state of the heart after myocardial infarction (MI) is the viability of the myocardial segment, i.e., if the segment recovers its functionality upon revascularization. MRI performed several minutes after the injection of a contrast agent (delayed enhancement-MRI or DE-MRI) is a method of choice to evaluate the extent of MI, and by extension, to assess viable tissues after an injury. The Emidec dataset is composed of a series of exams with DE-MR images in short axis orientation covering the left ventricle from normal cases or patients with myocardial infarction, with the contouring of the myocardium and diseased areas (if present) from experts in the dom…

Contouringmedicine.medical_specialtyInformation Systems and ManagementShort axisbusiness.industrymedicine.medical_treatmentDelayed enhancementEmergency department030204 cardiovascular system & hematologymedicine.diseaseRevascularization030218 nuclear medicine & medical imagingComputer Science Applications03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureVentriclemedicineSegmentationMyocardial infarctionRadiologybusinessInformation SystemsData
researchProduct

MR-tomographische Funktionsanalyse des linken Ventrikels

1993

The following contribution presents a continuous MRT analysis of the contraction and relaxation processes of healthy left ventricles giving reference values for contraction and relaxation velocities. For the total ventricle we have Vsyst. r. total = 342 +/- 47% LVEDV/sec and Vdiast. r. total = 303 +/- 59% LVEDV/sec. In relation to the end-diastolic (tomographic) volume (EDSV) significantly greater changes in volume per unit of time were measured apically compared to basal (systolic: 411 +/- 89% EDSV/sec apical vs 261 +/- 35% EDSV/sec basal; diastolic: 810 +/- 145% EDSV/sec apical vs 245 +/- 70% EDSV/sec basal). Occurrence of the end-systolic minimal volumes of apical tomographic layers was …

Contraction (grammar)business.industryChemistryDiastoleBlood volumeLeft VentriclesNuclear magnetic resonancemedicine.anatomical_structureVentricleReference valuesCirculatory systemmedicineRadiology Nuclear Medicine and imagingNuclear medicinebusinessEnd-systolic volumeRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Möglichkeiten der 16-Schicht-CT bei der linksventrikulären Funktionsbestimmung: Beurteilung zweier unterschiedlicher Software-Tools zur quantitativen…

2004

PURPOSE To determine global and regional left ventricular (LV) function from retrospectively gated multidetector row computed tomography (CT) by using two different semiautomated analysis tools and to correlate the results with those of magnetic resonance imaging (MRI). MATERIALS AND METHODS Nineteen patients (5 females, 14 males, mean age 69 years) underwent 16-slice spiral-CT (MS-CT) with standard technique without administration of beta-blockers for a decrease in the cardiac rate. Ten series of images were reconstructed at every 10 % of the RR-interval. With commercially available software capable of semiautomated contour detection, end-diastolic and end-systolic LV volumes (EDV and ESV)…

Contrast enhancementShort axisEjection fractionmedicine.diagnostic_testbusiness.industryLimits of agreementMagnetic resonance imagingStroke volumeStandard techniquemedicine.anatomical_structureVentricleMedicineRadiology Nuclear Medicine and imagingbusinessNuclear medicineRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Graph cut-based method for segmenting the left ventricle from MRI or echocardiographic images

2017

International audience; In this paper, we present a fast and interactive graph cut method for 3D segmentation of the endocardial wall of the left ventricle (LV) adapted to work on two of the most widely used modalities: magnetic resonance imaging (MRI) and echocardiography. Our method accounts for the fundamentally different nature of both modalities: 3D echocardiographic images have a low contrast, a poor signal-to-noise ratio and frequent signal drop, while MR images are more detailed but also cluttered and contain highly anisotropic voxels. The main characteristic of our method is to work in a 3D Bezier coordinate system instead of the original Euclidean space. This comes with several ad…

Convex hullHeart VentriclesEnergy MinimizationCoordinate systemEchocardiography Three-DimensionalHealth InformaticsBézier curve02 engineering and technology[SDV.IB.MN]Life Sciences [q-bio]/Bioengineering/Nuclear medicinecomputer.software_genreAutomated Segmentation030218 nuclear medicine & medical imaging[ SDV.IB.MN ] Life Sciences [q-bio]/Bioengineering/Nuclear medicine03 medical and health sciences0302 clinical medicineVoxelCut0202 electrical engineering electronic engineering information engineering[INFO.INFO-IM]Computer Science [cs]/Medical ImagingMagnetic-Resonance ImagesHumansRadiology Nuclear Medicine and imagingComputer vision[ SDV.IB ] Life Sciences [q-bio]/BioengineeringCardiac MriImage gradientMathematicsWhole MyocardiumLeft ventricular 3-D segmentationRadiological and Ultrasound Technology[ INFO.INFO-IM ] Computer Science [cs]/Medical ImagingEuclidean spacebusiness.industryComputer Graphics and Computer-Aided DesignMagnetic Resonance ImagingEchocardiographyConstrained Level-SetGraph (abstract data type)020201 artificial intelligence & image processing[SDV.IB]Life Sciences [q-bio]/BioengineeringComputer Vision and Pattern RecognitionArtificial intelligencebusiness2d-EchocardiographycomputerAlgorithmsGraph cutMRI
researchProduct

Diagnóstico etilógico de la disfunción ventricular izquierda con tomografia computerizada: comparación con coronariografía y cardiorresonancia

2012

[EN] Introduction and objectives To evaluate the capability of multidetector computed tomography to diagnose the coronary etiology of left ventricular dysfunction compared with using invasive coronary angiography and magnetic resonance. Methods Forty consecutive patients with left ventricular dysfunction of uncertain etiology underwent invasive coronary angiography and contrast magnetic resonance. All patients were evaluated with multidetector computed tomography including coronary calcium presence and score, noninvasive coronary angiography, and myocardial tissue assessment. Results The sensitivity and specificity of the presence of coronary calcium to identify left ventricular dysfunction…

Coronary angiographyMaleScoring systemCardiac magnetic resonanceCoronary angiographyESTADISTICA E INVESTIGACION OPERATIVACoronariografíaComputed tomographyReviewCoronary Artery DiseaseCoronary AngiographyDiagnostic accuracyVentricular Dysfunction LeftProspective StudiesAged 80 and overmedicine.diagnostic_testAngiocardiographyCalcinosisGeneral MedicineMiddle AgedMagnetic Resonance ImagingInvasive coronary angiographySensitivity and specificityCardiologycardiovascular systemTomografía computarizada con multidetectoresFemaleRadiologyHumanAdultmedicine.medical_specialtyContrast enhancementClinical articleSensitivity and SpecificityHeart left ventricle failureSingle testMultidetector computed tomographyNecrosisInternal medicineMultidetector computed tomographyMultidetector Computed TomographymedicineHumansClinical evaluationcardiovascular diseasesAgedCardiac patientbusiness.industryIntermethod comparisonMagnetic resonance imagingResonancia magnética cardiacaEtiologyCalciumCardiovascular magnetic resonanceAgatston calcium scoreCardiac magnetic resonancebusinessControlled study
researchProduct

Occlusion of the abdominal aorta during coronary angiography with fractional flow reserve due to migration of the left ventricle thrombus in a patien…

2019

Coronary angiographymedicine.medical_specialtyThrombocytosisbusiness.industrylcsh:RAbdominal aortalcsh:MedicineFractional flow reservemedicine.diseasemedicine.anatomical_structureImage in InterventionVentriclemedicine.arteryInternal medicineOcclusionmedicineCardiologyThrombusCardiology and Cardiovascular MedicinebusinessPostępy w Kardiologii Interwencyjnej
researchProduct

Examination of the fetal brain by transabdominal three-dimensional ultrasound: potential for routine neurosonographic studies

2006

Objective To evaluate the role of transabdominal three-dimensional (3D) ultrasound in the assessment of the fetal brain and its potential for routine neurosonographic studies. Methods We studied prospectively 202 consecutive fetuses between 16 and 24 weeks' gestation. A 3D ultrasound volume of the fetal head was acquired transabdominally. The entire brain anatomy was later analyzed using the multiplanar images by a sonologist who was expert in neonatal cranial sonography. The quality of the conventional planes obtained (coronal, sagittal and axial, at different levels) and the ability of the 3D multiplanar neuroscan to visualize properly the major anatomical structures of the brain were eva…

Corpus callosumFourth ventricleCisterna magnaUltrasonography PrenatalFetal DevelopmentImaging Three-DimensionalPregnancymedicineHumansRadiology Nuclear Medicine and imagingCingulate sulcus3D ultrasoundFetal headBrain DiseasesThird ventricleRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryBrainObstetrics and GynecologyGeneral MedicineAnatomyEchoencephalographymedicine.anatomical_structureReproductive MedicinePregnancy Trimester SecondCerebellar vermisFemalebusinessUltrasound in Obstetrics and Gynecology
researchProduct

Impact of diabetes on left ventricular geometry and diastolic function in hypertensive patients with chronic kidney disease

2010

DIABETES LEFT VENTRICLE CHRONIC KIDNEY DISEASE HYPERTENSION
researchProduct

Extracellular site of action of phenylalkylamines on L-type calcium current in rat ventricular myocytes.

1995

The effects of the phenylalkylamines verapamil, gallopamil, and devapamil on L-type calcium currents (ICa) were studied in ventricular myocytes from rat hearts using the whole-cell patch-clamp technique. In particular, the question was addressed, whether the pharmacological binding sites for these drugs were located at the inner and/or at the outer surface of the cell membrane. Therefore, tertiary verapamil, gallopamil, and devapamil and their corresponding quaternary derivatives were applied either from the outside or the inside of the cell membrane. Extracellular application of verapamil, gallopamil and devapamil (each at 3 microM) reduced ICa to 16.1 +/- 8.6%, 11 +/- 8.9%, and 9.3 +/- 6%…

DevapamilGallopamilPatch-Clamp TechniquesHeart Ventricleschemistry.chemical_elementPharmacologyCalciumRats Sprague-Dawleychemistry.chemical_compoundmedicineExtracellularAnimalsPatch clampGallopamilPharmacologyBinding SitesChemistryCalcium channelCell MembraneGeneral MedicineCalcium Channel BlockersRatsVerapamilcardiovascular systemVerapamilCalcium ChannelsIntracellularmedicine.drugNaunyn-Schmiedeberg's archives of pharmacology
researchProduct