Search results for "video"

showing 10 items of 1348 documents

A Review of Recent Range Image Registration Methods with Accuracy Evaluation

2007

International audience; The three-dimensional reconstruction of real objects is an important topic in computer vision. Most of the acquisition systems are limited to reconstruct a partial view of the object obtaining in blind areas and occlusions, while in most applications a full reconstruction is required. Many authors have proposed techniques to fuse 3D surfaces by determining the motion between the different views. The first problem is related to obtaining a rough registration when such motion is not available. The second one is focused on obtaining a fine registration from an initial approximation. In this paper, a survey of the most common techniques is presented. Furthermore, a sampl…

0209 industrial biotechnologyRegistrationComputer scienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONImage registration02 engineering and technologycomputer.software_genre[ INFO.INFO-CV ] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Motion (physics)020901 industrial engineering & automation0202 electrical engineering electronic engineering information engineeringRange imageComputer vision3D reconstructionComputingMilieux_MISCELLANEOUSbusiness.industry3D reconstruction[INFO.INFO-CV]Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Object (computer science)Sample (graphics)Range (mathematics)Signal ProcessingOutlier020201 artificial intelligence & image processingComputer visionComputer Vision and Pattern RecognitionNoise (video)Data miningArtificial intelligencebusinesscomputer
researchProduct

Tracking Moving Objects With a Catadioptric Sensor Using Particle Filter

2011

International audience; Visual tracking in video sequences is a widely developed topic in computer vision applications. However, the emergence of panoramic vision using catadioptric sensors has created the need for new approaches in order to track an object in this type of images. Indeed the non-linear resolution and the geometric distortions due to the insertion of the mirror, make tracking in catadioptric images a very challenging task. This paper describes particle filter for tracking moving object over time using a catadioptric sensor. In this work different problems due to the specificities of the catadioptric systems such as geometry are considered. The obtained results demonstrate an…

0209 industrial biotechnologybusiness.industryComputer scienceparticle filtersComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION[INFO.INFO-CV]Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]02 engineering and technologycatadioptric cameravisual tracking[ INFO.INFO-CV ] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Catadioptric system020901 industrial engineering & automation[INFO.INFO-CV] Computer Science [cs]/Computer Vision and Pattern Recognition [cs.CV]Robustness (computer science)Video tracking0202 electrical engineering electronic engineering information engineeringClutterCatadioptric sensor020201 artificial intelligence & image processingComputer visionArtificial intelligenceImage sensorParticle filterbusinessImage resolution
researchProduct

Awake video laryngoscopy – A revolution in the management of the anticipated difficult airway?

2016

03 medical and health sciences0302 clinical medicineAnesthesiology and Pain MedicineVideo laryngoscopy030202 anesthesiologybusiness.industryAnesthesiaMedicine030208 emergency & critical care medicineCritical Care and Intensive Care MedicinebusinessDifficult airwayTrends in Anaesthesia and Critical Care
researchProduct

Type of chromosome abnormality affects embryo morphology dynamics.

2016

Objective To study the differences in the cleavage time between types of embryo chromosomal abnormalities and elaborate algorithm to exclude aneuploid embryos according to the likelihood to be euploid. Design Retrospective cohort study. Setting University affiliated private center. Patient(s) Preimplantational genetic screening patients (n = 112) including cases of advanced maternal age, repeated implantation failure, and recurrent miscarriage. A total of 485 embryos were analyzed. Intervention(s) None. Main Outcome Measure(s) All biopsied embryos were cultured in an incubator with time-lapse technology, cleavage timing from insemination to day 3 and all kinetic parameters that have been de…

0301 basic medicineAdultBiopsyAneuploidyEmbryonic DevelopmentChromosome DisordersFertilization in VitroBiologyTime-Lapse ImagingAndrology03 medical and health sciences0302 clinical medicinePredictive Value of TestsPregnancyRisk FactorsRecurrent miscarriagemedicineOdds RatioChromosomes HumanHumansAdvanced maternal ageGenetic TestingPreimplantation DiagnosisRetrospective StudiesGeneticsChromosome AberrationsComparative Genomic Hybridization030219 obstetrics & reproductive medicineMicroscopy VideoObstetrics and GynecologyRetrospective cohort studyEmbryoOdds ratiomedicine.diseaseAneuploidyConfidence intervalKinetics030104 developmental biologyBlastocystLogistic ModelsReproductive Medicineembryonic structuresChromosome abnormalityFemaleFertility and sterility
researchProduct

Combination of metabolism measurement and a time-lapse system provides an embryo selection method based on oxygen uptake and chronology of cytokinesi…

2016

Objective To evaluate correlations between oxygen consumption (OC) measurements before and after embryo cytokinesis, observing OC during embryo cleavages and combining that information with morphokinetics to relate to implantation potential. Design Prospective cohort study. Setting University-affiliated private IVF unit. Patient(s) A total of 1,150 injected oocytes in 86 first oocyte donation cycles with embryo transfer on day 3. Intervention(s) None. Main Outcome Measurement(s) We analyzed the embryo OC and combined this data with the cytokinesis event, exact timing (in hours) of blastomeric cleavages, with the use of an incubator equipped with time-lapse videography, gathering a total of …

0301 basic medicineAdultmedicine.medical_specialtyanimal structuresTime FactorsAdolescentPregnancy RateCell SurvivalTransducersVideo RecordingBiologyTime-Lapse ImagingAndrologyEmbryo Culture Techniques03 medical and health sciencesYoung Adult0302 clinical medicinePredictive Value of TestsPregnancymedicineHumansEmbryo ImplantationProspective StudiesSperm Injections IntracytoplasmicCytokinesis030219 obstetrics & reproductive medicineMiniaturizationEmbryogenesisObstetrics and GynecologyEmbryoMetabolismEquipment DesignEmbryo TransferEmbryo MammalianEmbryo transferSurgeryOxygenPregnancy rate030104 developmental biologyTreatment OutcomeReproductive Medicineembryonic structuresFemaleSelection methodEnergy MetabolismEmbryo qualityCytokinesisFertility and sterility
researchProduct

Brain histamine and behavioral neuroscience

2017

ABSTRACT NON PREVISTO DALLA PUBBLICAZIONE

0301 basic medicineCarboxy-LyasesVideo RecordingEditorial: NeuroscienceBehavioral neuroscienceSettore BIO/09 - Fisiologiabehavioral sequenceHistonesMice03 medical and health scienceschemistry.chemical_compound0302 clinical medicineAnimalsHumansMedicineMotor NeuronsBehaviorBehavior Animalbusiness.industryNeurosciencesBrainhistaminePhenotype030104 developmental biologyOncologychemistryAnesthesiaBehavior; Behavioral sequence; Histamine; Neuroscience; T-pattern; OncologyT-patternbusinessNeuroscience030217 neurology & neurosurgeryHistamineTourette SyndromeNeuroscienceOncotarget
researchProduct

Effect of video capture time on sperm kinematic parameters in breeding boars

2019

Abstract Computer Assisted Semen Analysis (CASA) technology is being a common tool in the seminal analysis for seminal doses production in farm animals. The aim of the present work was to define the optimal capturing time for a correct evaluation of boar sperm motility. Six sexually mature boars from the Topigs Lines, were used as semen donors. ISASv1 CASA-Mot system was used with an image acquisition rate of 50 Hz for two seconds capturing. Obtained video frames were fragmented into four segments corresponding to 0.5, 1.0, 1.5 and 2.0 s. ISASD4C20 counting chambers, warmed at 37 °C were used. Total and progressive motility were not affected by capture time. Capture time had a significant e…

0301 basic medicineGeneral Veterinarymedicine.diagnostic_testurogenital systemVideo capture0402 animal and dairy science04 agricultural and veterinary sciencesKinematicsBiologySemen analysis040201 dairy & animal scienceSpermAndrology03 medical and health sciences030104 developmental biologymedicineImage acquisitionAnimal Science and ZoologySemen DonorsBoar spermLivestock Science
researchProduct

Portable remote photoplethysmography device for monitoring of blood volume changes with high temporal resolution

2016

The compact remote photoplethysmography device for monitoring of blood volume pulsations from human skin were developed. The prototype device comprises electronics board with twelve circullary oriented bright near-infrared LED illuminators, which are precisely controlled, high-speed video camera and battery charging circuit. Device was tested in laboratory and could be used for non-contact monitoring of human blood volume changes in palm.

0301 basic medicineHuman bloodComputer sciencebusiness.industryComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONBattery (vacuum tube)Video cameraBlood volume01 natural scienceslaw.invention010309 optics03 medical and health sciences030104 developmental biologylawPhotoplethysmogram0103 physical sciencesHigh temporal resolutionbusinessComputer hardwareBiomedical engineeringVolume (compression)2016 15th Biennial Baltic Electronics Conference (BEC)
researchProduct

Conformational dynamics of a single protein monitored for 24 hours at video rate

2018

We use plasmon rulers to follow the conformational dynamics of a single protein for up to 24 h at a video rate. The plasmon ruler consists of two gold nanospheres connected by a single protein linker. In our experiment, we follow the dynamics of the molecular chaperone heat shock protein 90 (Hsp90), which is known to show “open” and “closed” conformations. Our measurements confirm the previously known conformational dynamics with transition times in the second to minute time scale and reveals new dynamics on the time scale of minutes to hours. Plasmon rulers thus extend the observation bandwidth 3–4 orders of magnitude with respect to single-molecule fluorescence resonance energy transfer a…

0301 basic medicineLetterProtein ConformationMolecular ConformationFOS: Physical sciencesHsp90Bioengineeringsingle molecule02 engineering and technology7. Clean energyQuantitative Biology - Quantitative Methods03 medical and health sciencesMolecular dynamicsFluorescence Resonance Energy TransferNanotechnologyGeneral Materials ScienceHSP90 Heat-Shock ProteinsPhysics - Biological PhysicsQuantitative Methods (q-bio.QM)PlasmonPhysicsVideo rateMechanical EngineeringProtein dynamics92Biomolecules (q-bio.BM)General ChemistrySurface Plasmon Resonance021001 nanoscience & nanotechnologyCondensed Matter PhysicsGold nanospheres030104 developmental biologyFörster resonance energy transferQuantitative Biology - BiomoleculesBiological Physics (physics.bio-ph)Chemical physicsFOS: Biological sciencesprotein dynamicsPlasmon rulernonergodicityGold0210 nano-technologyLinker
researchProduct

Apnea events in neonatal age: A case report and literature review.

2019

Abstract Background Among the most common autonomic signs visible in preterm neonates, apnea can represent the first sign of several neurologic and non-neurologic disorders, and seizure is a relatively infrequent cause. Herein authors present a case of neonatal autonomic apnea, discussing the polygraphic video-EEG features of this pathological entity and the differential diagnosis with central apnea and autonomic apnea. Case report A female preterm Caucasian infant (29 + 4 weeks' gestational age (GA)), first twin of a twin pregnancy, at birth was intubated and surfactant administration was performed. She was ventilated via invasive ventilation for three days, with subsequent weaning with no…

0301 basic medicineLevetiracetamCentral apneaVideo RecordingDiseasesInfant Premature Diseases0302 clinical medicinenewbornDiagnosisHypoxiaApneaSleep apneaGestational ageElectroencephalographyGeneral MedicineSleep Apnea CentralAnesthesiaNervous System Diseases; Bradycardia; Cyanosis; Diagnosis Differential; Humans; Hypoxia; Infant Newborn; Infant Premature; Infant Premature Diseases; ; Sleep ApneaBreathingAnticonvulsantsFemalemedicine.symptomInfant PrematureBradycardiaSleep ApneaContext (language use)Gestational AgeNODiagnosis Differential03 medical and health sciencesSeizuresHeart ratemedicineBradycardiaDiseases in TwinsHumansPrematureCyanosisbusiness.industryInfant NewbornInfantapneamedicine.disease030104 developmental biologyAutonomic Nervous System DiseasesDifferentialNervous System Diseasesbusinesspreterm030217 neurology & neurosurgeryneurologic disorders
researchProduct