Search results for "vision."
showing 10 items of 4900 documents
Corrective loops involved in fast aiming movements: effect of task and environment
1998
In daily living, we continuously interact with our environment. This environment is rarely stable and living beings show remarkable adaptive capacities. When we reach for an object, it is necessary to localize the position of this object with respect to our own body before programming an adequate arm movement. If the target remains stable, the programmed movement brings the hand near the target. However, what happens when the target suddenly jumps to another position in space? The aim of this work was to investigate how rapid aiming movements are corrected when the target is displaced close to movement onset. Our results reveal that rapid movements can be modified and that the efficiency of…
Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…
2012
AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…
Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses
2011
PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…
Parental modeling, education and children's sports and TV time: The ENERGY-project
2014
Abstract Objective We assessed whether differences in children's sports participation and television time according to parental education were mediated by parental modeling. Moreover, we explored the differences between parental and child reports on parental sports participation and television time as potential mediators. Methods 5729 children and 5183 parents participating in the EuropeaN Energy balance Research to prevent excessive weight Gain among Youth (ENERGY-project) during 2010 in seven European countries provided information on sports participation and television time using validated self-report questionnaires. Multilevel country-specific mediation models analyzed the potential med…
Seeing odors in color: Cross-modal associations in children and adults from two cultural environments
2018
International audience; We investigated the occurrence and underlying processes of odor–color associations in French and American 6- to 10-year-old children (n = 386) and adults (n = 137). Nine odorants were chosen according to their familiarity to either cultural group. Participants matched each odor with a color, gave hedonic and familiarity judgments, and identified each odor. By 6 years of age, children displayed culture-specific odor–color associations, but age differences were noted in the type of associations. Children and adults in both cultural groups shared common associations and formed associations that were unique to their environment, underscoring the importance of exposure le…
Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration
2011
Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…
Can colours be used to segment words when reading?
2015
Rayner, Fischer, and Pollatsek (1998, Vision Research) demonstrated that reading unspaced text in Indo-European languages produces a substantial reading cost in word identification (as deduced from an increased word-frequency effect on target words embedded in the unspaced vs. spaced sentences) and in eye movement guidance (as deduced from landing sites closer to the beginning of the words in unspaced sentences). However, the addition of spaces between words comes with a cost: nearby words may fall outside high-acuity central vision, thus reducing the potential benefits of parafoveal processing. In the present experiment, we introduced a salient visual cue intended to facilitate the process…
Realignment of myocardial first-pass MR perfusion images using an automatic detection of the heart-lung interface
2004
International audience; Abstract: Magnetic resonance first-pass imaging of a bolus of contrast agent is well adapted to distinguish normal and hypoperfused areas of the myocardium. In most cases, the signal intensity-time curves in user defined regions of interest (ROI) are studied. As image acquisition is ECG-gated, the images are acquired at the same moment in the cardiac cycle, and the basic shape of the heart is similar from one view to the next. However, superficial respiratory motion can displace the heart in the short-axis plane. The aim of this study is to correct for the respiratory motion of the heart by performing an automatic realignment of the myocardial ROI based on a method t…
Comparison of contrast-enhanced MR angiography to intraarterial digital subtraction angiography for evaluation of peripheral arterial occlusive disea…
2010
Purpose To evaluate the efficacy and safety of 0.1 mmol/kg gadodiamide administration for contrast-enhanced magnetic resonance angiography (CE-MRA) in detecting hemodynamically relevant main stenosis (ie, ≥50% or occlusion) of aortoiliac arteries. Materials and Methods In a multicenter, phase 3, controlled study, patients with suspected or proven peripheral arterial occlusive disease (PAOD) underwent CE-MRA with administration of gadodiamide. Intraarterial digital subtraction angiography (IA-DSA) was used as the reference. The study was approved by all Institutional Review Boards or Institutional Ethic Committees prior to commencement of patient recruitment and written informed consent was …
Kardiale MRT : Änderungen der normalisierten myokardialen Gadolinium-Anreicherung über die Zeit nach Kontrastmittelinjektion in Patienten mit akuter …
2011
PURPOSE An increased normalized gadolinium accumulation (NGA) in the myocardium during early washout has been used for the diagnosis of acute myocarditis (AM). Due to the fact that the pharmacokinetics of contrast agents are complex, time-related changes in NGA after contrast injection are likely. Because knowledge about time-related changes of NGA may improve the diagnostic accuracy of MR, our study aimed to estimate the time course of NGA after contrast injection in patients as well as in healthy volunteers. MATERIALS AND METHODS An ECG-triggered inversion recovery SSFP sequence with incrementally increasing inversion times was repetitively acquired over the 15 minutes after injection of …