Search results for "vision."
showing 10 items of 4900 documents
Prevalence of refractive errors in the European adult population: the Gutenberg Health Study (GHS).
2014
Objective To study the distribution of refractive errors among adults of European descent. Design Population-based eye study in Germany with15 010 participants aged 35–74 years. Methods The study participants underwent a detailed ophthalmic examination according to a standardised protocol. Refractive error was determined by an automatic refraction device (Humphrey HARK 599) without cycloplegia. Definitions for the analysis were myopia +0.5 D, astigmatism >0.5 cylinder D and anisometropia >1.0 D difference in the spherical equivalent between the eyes. Exclusion criterion was previous cataract or refractive surgery. Results 13 959 subjects were eligible. Refractive errors ranged from −21.5 to…
Choice of spatial frequency for contrast sensitivity evaluation after corneal refractive surgery.
2002
ABSTRACT PURPOSE: To study the utility of measurements of contrast sensitivity at different spatial frequencies as an index of visual recovery following refractive surgery. METHODS: Contrast sensitivity at 1.5, 3, 6, 12, and 18 c/deg was measured with the Stereo Optical FACT chart in 20 patients after photorefractive keratectomy (PRK) using the Nidek EC-5000 excimer laser system, and in 18 patients following laser in situ keratomileusis (LASER). Contrast sensitivity was measured preoperatively and 1, 3, 6, and 12 months after surgery. RESULTS: Results showed a statistically significant reduction (P<01) in contrast sensitivity at all spatial frequencies in PRR patients during the first an…
Fixation pattern analysis with microperimetry in nystagmus patients
2015
Objective: To assess the usefulness of microperimetry (MP) as an additional objective method for characterizing the fixation pattern in nystagmus. Design: Prospective study. Participants: Fifteen eyes of 8 subjects (age, 12–80 years) with nystagmus from the Lluís Alcanyís Foundation (University of Valencia, Spain) were included. Methods: All patients had a comprehensive ophthalmologic examination including a microperimetric examination (MAIA, CenterVue, Padova, Italy). The following microperimetric parameters were evaluated: average threshold (AT), macular integrity index (MI), fixating points within a circle of 1° (P1) and 2° of radius (P2), bivariate contour ellipse area (BCEA) considerin…
Post-LASIK Visual Quality With a Corneoscleral Contact Lens to Treat Irregular Corneas.
2015
To evaluate the visual quality results of fitting a corneoscleral contact lens with multiaspheric geometry design (MAGD CScL) in subjects with irregular corneas after laser-assisted in situ keratomileusis (LASIK) surgery.From a database of patients evaluated for scleral contact lenses, we identified those with irregular corneas and visual problems after they underwent LASIK surgery for correcting myopia. They manifested unsatisfactory visual quality with their current contact lenses or glasses. Therefore, a MAGD CScL was fitted and monitored according to standardized fitting methodology. A diagnostic trial set was used in the fitting process. Visual acuity (VA), subjective visual quality (S…
Subjective fixation disparity affected by dynamic asymmetry, resting vergence, and nonius bias.
2011
PURPOSE This study was undertaken to investigate how subjectively measured fixation disparity can be explained by (1) the convergent-divergent asymmetry of vergence dynamics (called dynamic asymmetry) for a disparity vergence step stimulus of 1° (60 arc min), (2) the dark vergence, and (3) the nonius bias. METHODS Fixation disparity, dark vergence, and nonius bias were measured subjectively using nonius lines. Dynamic vergence step responses (both convergent and divergent) were measured objectively. RESULTS In 20 subjects (mean age, 24.5 ± 4.3 years, visual acuity, ≥1.0; all emmetropic except for one with myopia, wearing contact lenses), multiple regression analyses showed that 39% of the v…
Differences in visual performance of AcrySof ReSTOR IOL in high and low myopic eyes.
2009
PURPOSE To determine the differences in refractive and visual results obtained in eyes with high and low myopia after multifocal intraocular lens (IOL) implantation. METHODS Monocular visual acuity for distance and near, with and without distance correction, and photopic and mesopic contrast sensitivity were measured at 6 months after surgery in 152 myopic eyes implanted with the AcrySof ReSTOR Natural (SN60D3) IOL. Two groups were created: high and low myopia (76 eyes in each). RESULTS Monocular best distance-corrected visual acuity was 0.02+/-0.06 logMAR for low myopes and 0.05+/-0.09 logMAR for high myopes. Monocular best distance-corrected near visual acuity was 0.04+/-0.05 and 0.07+/-0…
Visual quality differences between orthokeratology and LASIK to compensate low-moderate myopia.
2013
PURPOSE: To assess the differences in visual performance between orthokeratology (ortho-k) and laser in situ keratomileusis (LASIK) for the treatment of low-to-moderate myopia. METHODS: An adaptive optics visual simulator (Imagine Eyes) was used to simulate the wavefront aberration patterns induced by ortho-k and LASIK for low and moderate myopia on 10 healthy eyes. Visual acuity (VA) at 100%, 50%, and 10% contrast levels and contrast sensitivity (CS) at 10, 20 and 25 cycles per degree (cpd) were then measured for 3- and 6-mm pupil sizes. RESULTS: Differences in VA for 3-mm pupil diameter were not found between ortho-k and LASIK. For 6-mm pupil size, LASIK provided significantly better VA v…
Timing of cell division in human cleavage-stage embryos is linked with blastocyst formation and quality
2012
Noninvasive markers of embryo quality are being sought to improve IVF success. The present study aimed to discover possible associations between embryo division kinetics in the cleavage stage, the subsequent ability of human embryos to reach the blastocyst stage and the resulting blastocyst morphology. A retrospective cohort study analysed 834 embryos from 165 oocyte donation couples using a time-lapse monitoring system that allowed the recording of the exact timings for key events related to embryo development. Timing parameters were categorized into four quartiles. The probability of an embryo developing to a blastocyst was linked to a strict chronology of development. To further evaluate…
Are media reports able to cause somatic symptoms attributed to WiFi radiation? An experimental test of the negative expectation hypothesis
2017
People suffering from idiopathic environmental intolerance attributed to electromagnetic fields (IEI-EMF) experience numerous non-specific symptoms that they attribute to EMF. The cause of this condition remains vague and evidence shows that psychological rather than bioelectromagnetic mechanisms are at work. We hypothesized a role of media reports in the etiology of IEI-EMF and investigated how somatosensory perception is affected. 65 healthy participants were instructed that EMF exposure can lead to enhanced somatosensory perception. Participants were randomly assigned to watch either a television report on adverse health effects of EMF or a neutral report. During the following experiment…
Vision evaluation in people with Down's syndrome.
1994
We tested the colour vision of 72 people with Down's syndrome using the Ishihara test and an anomaloscope. We found that 13 of the subjects, 6 males and 7 females, had defective colour vision according to Pickford's classification. In monocular vision 10 eyes were protan (five simple, three extreme and two deviant), one eye was simple deuteranomalous and the remaining eyes were normal: in binocular vision four of the subjects were protan (two simple and two deviant), two subjects were deutan (one simple and one deviant) and the rest were normal. Many of our subjects had lens opacities, strabismus, nystagmus, hypermetropia, high myopia and astigmatism, confirming literature reports. The cont…